API 610 OH2 Solvent Pump – Centerline‑Mounted Overhung Pump for Hydrocarbon Solvents

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
The API 610 OH2 solvent pump is a horizontal, overhung, centerline‑mounted single‑stage end suction centrifugal pump designed for hydrocarbon solvents – 6#, 120#, 200# solvent oils, D‑series, and light/medium/heavy solvents in refineries and chemical plants. Solvents are volatile, flammable, and have strong dissolving power that swells ordinary elastomers. Light solvents (similar to naphtha) require dual mechanical seals (Plan 53A) with FFKM elastomers, Ex d IIB T6, and NPSHa margin ≥1.0–1.5 m. Heavy solvents (higher flash point) can use single seal (Plan 11) with FKM and Ex d IIB T4. WCB casing, 316L impeller, copper‑free. Back pull‑out design. Contact info@hyrig.com

Conatct For Details
DetailReview(0)Additional

The API 610 OH2 (Overhung Type 2) solvent pump is the standard for handling hydrocarbon solvents in refineries, chemical plants, and solvent production units. Solvents include 6#, 120#, 200# solvent oils, D‑series dearomatized solvents, and light/medium/heavy aliphatic solvent mixtures. These fluids are volatile, flammable, and have strong solvency – they swell and degrade ordinary elastomers (NBR, EPDM). The design requirements vary significantly between light solvents (flash point close to naphtha/gasoline) and heavy solvents (higher flash point, less volatile). The centerline‑mounted casing (OH2, never OH1) ensures thermal stability and pipe strain resistance for continuous chemical service.

Structural Definition – OH2 per API 610

  • Horizontal, single‑stage, single‑suction, end suction (axial inlet, radial/top discharge).

  • Centerline‑mounted – casing supported from the centreline flange.

  • Overhung impeller – mounted at the shaft end, outside the bearing housing.

  • Radially split volute casing.

  • Closed impeller.

  • Back pull‑out design – rotor, seal, and bearing housing removable without disturbing piping or motor.

  • Heavy‑duty bearing housing with temperature and vibration monitoring.

Applicable Media – Hydrocarbon Solvents

Fully applicable:

  • 6# solvent oil (light, low flash point), 120# solvent oil (medium), 200# solvent oil (heavy)

  • D‑series solvents (D30, D40, D60, D80, D100, D140)

  • Light aliphatic solvents, medium aliphatic solvents, heavy aliphatic solvents

  • Extraction solvents, washing oils, paint thinners, degreasing solvents

  • Unit feed, reflux, product transfer, tank farm storage, loading, pipeline export

Not applicable (use other pump types):

  • High solids, abrasive particles, heavy residues

  • Strong acids, bases, or polar solvents (ketones, esters – require different materials)

Media & Operating Characteristics – Solvents (Light vs. Heavy)

Solvents vary widely in volatility, flash point, and cavitation risk. Two distinct categories:

PropertyLight Solvents (e.g., 6#, D30)Heavy Solvents (e.g., 200#, D140)
Boiling point range60–120°C150–250°C
Flash point–20 to +30°C60–100°C
Vapour pressure at 20°C0.1–0.5 barVery low (<0.01 bar)
Cavitation riskHighLow to moderate
NPSH margin required≥1.0–1.5 m≥0.5–1.0 m
Typical sealing requirementDual mechanical seal (Plan 53A)Single mechanical seal (Plan 11)
Explosion classEx d IIB T6Ex d IIB T4

Performance Boundaries (Solvent Duty)

  • Flow: 5 – 2000 m³/h (typical 10 – 1000 m³/h)

  • Head: 20 – 250 m (single‑stage)

  • Design pressure: Typically Class 150 or 300 (2.0–5.0 MPa / 20–50 bar)

  • Temperature: –10°C to +150°C (ambient to warm; no heating required)

  • Speed: 1480 or 2980 rpm

  • NPSH requirement (light solvents): NPSHa ≥ NPSHr + 1.0–1.5 m – similar to naphtha/gasoline. Inducer optional for low NPSHa.

  • NPSH requirement (heavy solvents): Standard margin ≥0.5–1.0 m – inducer rarely needed.

Key Design Configuration – Solvent OH2 (Dual Configuration Based on Flash Point)

1. Hydraulic Design – Depending on Solvent Grade

  • For light solvents (low flash point, high volatility): closed impeller with low‑NPSH inlet, recommended NPSHa margin of 1.5 m.

  • For heavy solvents (high flash point, low volatility): standard impeller, standard NPSH margin.

2. Mechanical Sealing – API 682 (Critical – Solvent Swelling)

Solvents aggressively swell standard elastomers. Seal elastomer selection is mandatory.

For light solvents (volatile, low flash point, e.g., 6#, D30):

  • Mandatory: Dual mechanical seal (pressurised). Single seals are not permitted due to flammability and volatility.

  • Preferred plan: Plan 53A (pressurised dual seal with external barrier fluid reservoir). Barrier fluid pressure ≥2 bar above seal chamber pressure.

  • Alternate plan: Plan 54 for hot or heavy duty service.

For heavy solvents (high flash point, low volatility, e.g., 200#, D140):

  • Standard: Single mechanical seal with Plan 11 (self‑flush from pump discharge). This is acceptable because heavy solvents are less volatile and have higher flash point.

  • Optional: Single seal with Plan 21 (cooled flush) for higher temperature service.

Elastomer requirement (mandatory for all solvents):

  • FFKM (perfluoroelastomer, e.g., Kalrez, Chemraz) or FKM (Viton) – both resist solvent swelling. FFKM is preferred for light solvents and elevated temperatures; FKM is acceptable for heavy solvents at moderate temperatures.

  • Prohibited: NBR, EPDM – these swell rapidly and fail in hydrocarbon solvents.

3. Material Combination (Copper‑Free, Corrosion‑Resistant)

Pure aliphatic solvents are non‑corrosive, but copper‑free construction is required per APIRP 2003.

  • Casing: WCB carbon steel (standard for all solvent grades).

  • Impeller / Wear rings: 316L stainless steel or 12% chrome (CA6NM) – 316L preferred for corrosion resistance against trace acids or chlorides.

  • Shaft: High‑strength alloy steel (4140/42CrMo) – large diameter, low deflection. No copper, brass, or bronze.

  • NACE MR0175: Not required for pure solvents; may be needed if solvent contains trace H₂S from cracked sources.

4. Explosion‑Proof & Safety (Dual Rating)

Solvent GradeExplosion ClassTemperature Class
Light solvents (6#, D30, low flash)Ex d IIBT6 (85°C)
Heavy solvents (200#, D140, high flash)Ex d IIBT4 (135°C)
  • Anti‑static features: Shaft grounding, flange earthing straps, conductive gaskets – mandatory for all solvents.

  • Leak detection: For light solvents with dual seals, seal pot pressure/level alarms. For heavy solvents with single seals, consider VOC detector.

5. Bearing & Lubrication

  • Heavy‑duty angular contact thrust bearings.

  • Lubrication: Oil mist (preferred for petrochemical plants), oil ring, or forced lube.

  • Bearing temperature RTD and vibration monitoring (API 670) – recommended for light solvent pumps.

6. Support & Construction

  • Centerline support (OH2) – handles temperature swings up to 150°C.

  • Back pull‑out design – allows seal replacement without disturbing piping, critical for light solvent service where seal integrity is safety‑critical.

Why OH2 (Not OH1 or BB) for Solvents

Pump TypeSuitability for SolventsReason
OH2 (centerline)MandatoryThermal stability, back pull‑out, standard for chemical plants.
OH1 (foot‑mounted)ProhibitedPoor thermal alignment, lower nozzle load rating.
BB2/BB3 (between‑bearing)Over‑specifiedHigher cost, larger footprint; only justified for flow >2000 m³/h or head >250 m.

Comparison – Light Solvents vs. Heavy Solvents vs. Other Hydrocarbons (OH2)

FeatureLight Solvent (6#, D30)Heavy Solvent (200#, D140)Naphtha/GasolineDiesel
Flash point–20 to +30°C60–100°C–40 to –20°C55–80°C
Cavitation riskHighLow to moderateHighLow to moderate
NPSH margin required≥1.0–1.5 m≥0.5–1.0 m≥1.0–1.5 m≥0.5–1.0 m
Sealing typeDual seal (53A)Single seal (Plan 11)Dual sealSingle seal
Seal elastomerFFKMFKMFKMFKM
Explosion classEx d IIB T6Ex d IIB T4T6 (often)T4
MaterialWCB + 316LWCB + 12CrWCB + 12Cr/316LWCB + 12Cr

Why Refineries and Chemical Plants Specify OH2 for Solvents

  • Flexibility to handle light and heavy grades: The same OH2 platform can be configured with dual seals + T6 for light solvents or single seals + T4 for heavy solvents, reducing spare parts inventory.

  • Solvent‑resistant seals: Mandatory FFKM or FKM elastomers prevent swelling and premature failure – the #1 issue in solvent pump reliability.

  • Cavitation control: For light solvents, the generous NPSH margin prevents vaporisation, which would otherwise damage the impeller and cause seal leakage.

  • Safety compliance: Ex d IIB T6 for light solvents meets the highest electrical area classification for low‑flash solvents (e.g., 6# solvent oil, flash point below 30°C).

  • Maintainability: Back pull‑out design allows quick seal replacement without unbolting piping – important for production plants with frequent solvent grade changes.

For complete technical datasheets, sizing assistance, or a quotation for any API 610 OH2 solvent pump (6#, 120#, 200#, D‑series, light or heavy), please contact info@hyrig.com. We respond within 24 hours.