The API 610 OH2 (Overhung Type 2) gasoline pump is the refinery standard for handling gasoline, naphtha, and other volatile light hydrocarbons. Its centerline‑mounted casing (OH2, not foot‑mounted OH1) provides superior resistance to thermal expansion, pipe strain, and vibration – critical for low‑viscosity, high‑vapor‑pressure hydrocarbon services.
Why OH2 – Not OH1 – for Gasoline
Gasoline and light hydrocarbons experience frequent temperature changes (ambient to process warm) and are sensitive to pipeline stress. OH2 centerline support allows the casing to expand evenly around the shaft centerline, preventing misalignment. OH1 (foot‑mounted) is prohibited for gasoline due to thermal distortion risk and lower nozzle load capacity.
Structural Definition – OH2 per API 610
Horizontal, single‑stage, single‑suction, end suction (axial inlet, radial/top discharge).
Centerline‑mounted – casing supported from the centreline flange.
Overhung impeller – mounted at the shaft end, outside the bearing housing.
Radially split volute casing.
Closed impeller (low NPSH design).
Back pull‑out design – rotor, seal, and bearing housing removable without disturbing piping or motor.
Heavy‑duty bearing housing with vibration and temperature monitoring.
Applicable Media – Gasoline & Light Hydrocarbons
Fully applicable:
Automotive gasoline, reformed gasoline, stabilized gasoline
Naphtha (light naphtha, full‑range naphtha)
Light straight‑run naphtha, light coker naphtha
Low‑sulphur light hydrocarbons, volatile light ends
Blended hydrocarbons, gasoline tank farm transfer, product export, reflux, truck/rail loading pumps
Not applicable (use other pump types):
Heavy crude, residual fuels, high‑viscosity oils
Media containing large particles, catalyst fines, abrasives
Strong acids, strong caustics (unless special alloys)
Key Operating Conditions & Design Drivers
Gasoline and light hydrocarbons present specific challenges: very low viscosity (0.3–1.0 cP typical), extremely high vapour pressure (volatile), low flash point (flammable), and strong tendency to vaporise (cavitation). The OH2 gasoline pump must address:
High cavitation risk – low NPSH available in many tankage/loading scenarios.
Sealing integrity – any leakage creates immediate fire/explosion hazard.
Explosion safety – motor and pump must be ATEX/IECEx certified for Zone 1/2.
Property changes with temperature – viscosity, vapour pressure, and NPSHr all vary.
Performance Boundaries (Gasoline Duty)
Flow: 10 – 2000 m³/h (typical 50 – 1000 m³/h)
Head: 20 – 250 m (single‑stage)
Design pressure: Up to 5.0 MPa (50 bar) – commonly Class 150/300
Temperature: –20°C to +180°C (ambient to warm gasoline; no heavy‑oil high temperatures)
Speed: 1480/2980 rpm (2980 rpm common for compact light‑hydrocarbon pumps)
NPSH requirement: NPSHa ≥ NPSHr + 1.0–1.5 m (strict requirement; inducer recommended for low NPSHa)
Mandatory Design Features for Gasoline OH2
1. Hydraulic Design – Low NPSH
Closed impeller with optimised inlet geometry (low NPSHr).
Optional inducer (axial flow stage) for low NPSH applications (e.g., tank truck loading from atmospheric storage).
Large suction nozzle diameter to reduce inlet velocity.
2. Sealing System – API 682 – Highest Priority
Gasoline is volatile, low‑viscosity, and flammable – seal leakage is unacceptable.
Standard: Dual mechanical seals (pressurised or unpressurised).
Preferred flushing plans:
Plan 53A or 53B (pressurised dual seal with barrier fluid reservoir) – zero leakage to atmosphere.
Plan 54 (external pressurised barrier fluid system) – for severe service or high suction pressure.
Plan 11 + throttle bushing – only for very clean, low‑pressure light gasoline with excellent NPSH (less preferred).
Seal face materials: Carbon vs. silicon carbide or tungsten carbide – compatible with light hydrocarbon (no swelling, no extraction of seal elastomers).
Prohibited: Packed gland (chest) seals – unsafe for any gasoline service.
3. Materials (Gasoline‑Specific)
Gasoline requires copper‑free materials to prevent catalytic gum formation and to avoid sparking risks per NACE RP0178 / APIRP 2003.
Casing: WCB carbon steel (standard) or LCC for low temperature.
Impeller / Wear rings: 12% chrome (CA6NM) or 316L stainless steel – corrosion resistant, non‑sparking.
Shaft: High‑strength alloy steel (4140/42CrMo) – high rigidity, low deflection.
Bearing housing / gland: Carbon steel with copper‑free bearing isolators.
Copper‑free requirement: All wetted and non‑wetted parts (including bearing cage, fasteners, valve plugs) must be free of copper, brass, or bronze – eliminates galvanic corrosion risk and gum formation in gasoline.
4. Explosion‑Proof & Safety
Motor & pump assembly: ATEX / IECEx certified for hazardous area (Zone 1 or Zone 2).
Gas grouping: IIB (typical for gasoline) or IIC (hydrogen‑rich); temperature class T4 or T6.
Anti‑static design: Conductive shaft and casing grounding; anti‑static bearings (ceramic rolling elements) or electrical continuity devices.
Flange bonding: All flanges cross‑bonded and earthed to prevent static discharge.
Bearing housing isolation: Labyrinth seals prevent gasoline vapour ingress into bearing cavity.
5. Bearing & Lubrication
Heavy‑duty angular contact thrust bearings – handle axial thrust from high‑speed operation of low‑density fluids.
Lubrication: Oil mist (preferred for light hydrocarbon refineries) or oil ring with cooler. Bearing temperature monitoring (RTD) and vibration transmitters (API 670 compliant).
6. Support & Construction
Centerline support (OH2) – even thermal expansion, low nozzle loads.
Heavy‑duty bearing housing – stabilises high‑speed rotor (often 2980 rpm).
Back pull‑out design – allows seal replacement without removing casing from piping – critical for frequent seal inspection in gasoline service.
Selection Summary – API 610 OH2 Gasoline vs. Crude Oil OH2
| Parameter | Gasoline OH2 | Crude Oil OH2 |
|---|---|---|
| Viscosity | Very low (0.3–1 cP) | Low to medium (5–500 cP) |
| Cavitation risk | Very high (high vapour pressure) | Moderate |
| Sealing requirement | Dual seals mandatory (Plan 53/54) | Dual seals recommended for sour crude |
| Explosion protection | Ex d IIB T4/T6 – mandatory | Required for crude but less stringent |
| Copper‑free | Mandatory (APIRP 2003) | Not required |
| Heating / tracing | Not required (ambient to warm) | Often required for waxy crude |
| Common speed | 2980 rpm (higher speeds) | 1480 rpm (lower speeds) |
| Materials | WCB + 12Cr/316L, copper‑free | WCB/duplex + 12Cr/duplex, copper allowed |
Why OH2 is the Standard for Gasoline Pumps
Safety: Centerline support, dual seals, explosion‑proof construction, and copper‑free materials address every hazard of volatile hydrocarbons.
Reliability: Low NPSH hydraulic design prevents cavitation damage; heavy‑duty bearings handle refinery continuous operation (3+ years).
Maintainability: Back pull‑out design allows seal/cartridge replacement without breaking piping – reduces downtime.
Compliance: Fully meets API 610 12th Ed., API 682, ATEX, and refinery-specific requirements.
For complete technical datasheets, sizing assistance, or a quotation for any API 610 OH2 gasoline pump, please contact info@hyrig.com. We respond within 24 hours.