API 610 Pumps for Oil Shipping – Tankers, Chemical & LNG Carriers – Complete Selection Guide

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Oil shipping (tankers, chemical carriers, LNG carriers) requires pumps that are compact, slosh‑resistant (roll ±30°, pitch ±15°), explosion‑proof, and corrosion‑resistant to crude/product oils. API 610 provides five optimized types: VS6 vertical can‑type for cargo/ballast (compact, anti‑slosh), BB2 double‑suction for high‑flow scrub/ballast, OH2 for auxiliary (fuel/lube/fire), BB3 multistage for chemical/LNG high pressure, and VS1 deep‑set for bilge/emergency lift. This guide covers flow/head ranges, materials, and IMO/SOLAS compliance. Contact info@hyrig.com

Conatct For Details
DetailReview(0)Additional

Oil shipping – including crude oil/product tankers, chemical carriers, and LNG carriers – demands pumping systems that meet uniquely maritime requirements:

  • Compact installation – limited cargo deck and pump room space

  • Slosh/vibration resistance – vessel roll (±30°) and pitch (±15°), wave‑induced motion

  • Explosion‑proof and fire‑safe – flammable cargo (crude, gasoline, chemicals)

  • Corrosion resistance – crude oil, sour products, seawater ballast, chemicals

  • Continuous long‑run operation – port turnaround cycles, trans‑ocean voyages

  • International compliance – IMO MARPOL, SOLAS, OCIMF, API 610

API 610 provides five pump types ideally suited for oil shipping duties. Below is a structured guide.


1. VS6 (Vertically Suspended Type 6) – Vertical Can / Submersible Pump – Primary Cargo & Ballast Pump

Structural Definition (API 610 12th Edition)
Vertically suspended, motor and pump directly coupled (or short shaft). Single or multistage can‑type casing. Pump cartridge submerged inside cargo tank or ballast tank. No long intermediate shaft.

Oil Shipping Adaptability

  • Key Advantages:

    • Vertical footprint is only 1/3 of a horizontal pump – ideal for tight cargo tank hatches and pump rooms.

    • Fully or partially submerged design withstands vessel roll (±30°) and pitch (±15°) without suction loss.

    • Wetted parts in 316L stainless steel or Monel – resistant to crude oil, sour products (H₂S), and seawater.

    • API 610 rigid shaft design – shaft deflection at seal ≤50 μm; mechanical seal leakage ≤10 ml/h (API 682).

    • Explosion‑proof rating Ex d II BT4 or higher.

  • Scenarios: Cargo loading/unloading (crude, diesel, gasoline), ballast water injection/discharge, cargo stripping (bottom oil suction).

  • Representative Models: Sulzer TTMC series, Ebara VS6 vertical can pump.

  • Key Parameters: Flow 100–5000 m³/h, Head 50–500 m, Design pressure ≤100 bar, Temperature –20 to 120°C.


2. BB2 (Between Bearing Type 2) – Radially Split Double‑Suction Pump – High‑Flow Scrub & Ballast Water

Structural Definition (API 610)
Horizontal installation, radially split volute, single‑stage double‑suction impeller. Impeller between two bearing sets. Centreline support.

Oil Shipping Adaptability

  • Key Advantages:

    • Double‑suction impeller covers very high flows (500–10,000 m³/h) – ideal for rapid ballast water exchange and tank scrub/fill cycles.

    • Low NPSH requirement (NPSHr ≤3 m) – prevents cavitation during slosh conditions with fluctuating liquid levels.

    • Radially split casing – easy deck‑level maintenance. Spiral wound gasket seals meet API 610 para 6.3.10 – zero leak risk.

  • Scenarios: Large tanker ballast water systems, cargo tank washing (scrub water circulation), port terminal transfer.

  • Representative Models: Sulzer HSA series, Cameron BB2 double‑suction pump.

  • Key Parameters: Flow 500–10,000 m³/h, Head 20–150 m, Design pressure ≤40 bar, Temperature 0–80°C, Materials: duplex SS or carbon steel with rubber lining.


3. OH2 (Overhung Type 2) – Horizontal Overhung Centreline Support – Auxiliary Systems (Fuel, Lube, Fire)

Structural Definition (API 610)
Horizontal, radially split volute, single‑stage end suction. Impeller overhung from bearing housing. Centreline support for thermal stability.

Oil Shipping Adaptability

  • Key Advantages:

    • Compact, lightweight – fits auxiliary machinery spaces.

    • Centreline support maintains alignment under vessel vibration and thermal expansion.

    • Wide material selection – cast iron, bronze‑fitted, or 316SS – compatible with fuel oil, lube oil, fresh water, seawater.

    • Complies with SOLAS fire pump requirements (emergency fire water duty).

  • Scenarios: Fuel oil transfer and booster pumps, lubricating oil circulation pumps, emergency firewater jockey pumps, chemical additive injection on chemical carriers.

  • Representative Models: Sulzer CPN/CPT series, PumpWorks OH2 overhung pump.

  • Key Parameters: Flow 50–800 m³/h, Head 25–200 m, Design pressure ≤36 bar, Temperature –10 to 100°C.


4. BB3 (Between Bearing Type 3) – Axially Split Multistage – High‑Pressure & Chemical/LNG Transfer

Structural Definition (API 610)
Horizontal, axially split casing, multiple impellers in opposed arrangement. Bearings at both ends. High rigidity for medium to high pressure.

Oil Shipping Adaptability

  • Key Advantages:

    • Multistage pressurisation precisely matches high‑pressure requirements (30–200 bar) – for chemical carriers (toxic/high‑viscosity media) and LNG carrier pre‑cooling / boil‑off gas re‑condensation.

    • Opposed impeller design balances axial thrust – vibration ≤2.5 mm/s, resistant to vessel motion shocks.

    • Axially split casing allows quick inspection – meets API 610 3‑year continuous run life requirement.

    • Low‑temperature option (down to –196°C) for LNG service with special stainless steel and cold‑box design.

  • Scenarios: Chemical carrier toxic/corrosive product transfer, LNG carrier cooldown and circulation, high‑pressure tank washing on product tankers.

  • Representative Models: Sulzer MSD series, Westgarth BB3 multistage pump.

  • Key Parameters: Flow 50–3200 m³/h, Head 200–3000 m, Design pressure ≤250 bar, Temperature –196 to 150°C (cryogenic option). Materials: Hastelloy C276 or low‑temperature stainless steel.


5. VS1 (Vertically Suspended Type 1) – Vertical Turbine – Bilge & Emergency Lift

Structural Definition (API 610)
Vertically suspended, multistage diffuser bowl. Impeller/bowl submerged, connected to above‑deck motor via long shaft. Suitable for deep tanks and low liquid levels.

Oil Shipping Adaptability

  • Key Advantages:

    • Immersion depth up to 10 m – can reach bottom residue in cargo tanks, bilge wells, and ballast tanks.

    • Complies with IMO MARPOL requirements for bilge water and oily mixture disposal.

    • Vertical installation takes no deck space – fits double‑bottom compartments and wing tank corners.

    • Multistage diffuser design maintains stable head – flow fluctuation ≤5% under slosh conditions.

  • Scenarios: Oily bilge water lift to oily water separator, emergency residual cargo recovery, low‑level ballast tank drainage.

  • Representative Models: National Pump VS1 vertical turbine, Sulzer vertical sump pump variants.

  • Key Parameters: Flow 50–1500 m³/h, Head 50–500 m, Design pressure ≤60 bar, Wetted parts in duplex stainless steel, IP67 protection.


Oil Shipping – API 610 Selection Decision Matrix

API 610 TypeCore ScenarioFlow RangeHead RangePressure RangeMaterialKey Maritime Advantage
VS6Cargo handling, ballast, stripping100–5000 m³/h50–500 m≤100 bar316L / MonelCompact vertical, slosh‑resistant, Ex‑proof, rigid shaft
BB2High‑flow ballast, scrub water500–10000 m³/h20–150 m≤40 barDuplex / rubber‑linedVery high flow, low NPSH, easy maintenance
OH2Auxiliary (fuel, lube, fire)50–800 m³/h25–200 m≤36 barCast iron / SSSimple, vibration‑tolerant, SOLAS fire pump
BB3Chemical/LNG high pressure, cryogenic50–3200 m³/h200–3000 m30–250 barHastelloy / low‑temp SSHigh pressure, axial thrust balance, cryogenic option
VS1Bilge lift, emergency recovery50–1500 m³/h50–500 m≤60 barDuplex SSDeep immersion, low level suction, MARPOL compliant

Integration Principles – Shipboard & Ship‑to‑Shore

  • Ship‑to‑shore compatibility: Tanker discharge (VS6 cargo pump, discharge pressure 10–30 bar) → Terminal (BB2 high‑flow booster / transfer pump) → Onshore storage. Ensure pressure and flow matching without extra boosters.

  • System integration onboard: Common maintenance access for ballast (VS6/BB2), scrub (BB2), emergency fire (OH2). Use same pump family (e.g., Sulzer series) to reduce spare parts inventory.

  • Safety & compliance: All pumps meet API 610 12th Edition, ISO 13709, IMO MARPOL (bilge/oily water), SOLAS (fire safety), OCIMF requirements. Explosion‑proof ≥Ex d II BT4. Seals per API 682 (≤10 ml/h leakage).

  • Anti‑slosh design: Pump base with resilient mounts; impellers dynamically balanced (Grade G2.5). VS6/VS1 built‑in vortex breakers to prevent flow fluctuation and cavitation during rolling.


Typical Oil Shipping Flow Examples

Large Crude Oil Tanker:
Cargo handling (VS6 can pump) → Ballast exchange (BB2 double‑suction) → Tank washing (BB2) → Bilge water recovery (VS1) → Emergency fire (OH2)

Chemical Carrier:
Toxic/high‑pressure product transfer (BB3 multistage) → Ballast system (VS6) → Additive injection (OH2) → Oily bilge treatment (VS1)

LNG Carrier:
Cryogenic pre‑cooling (BB3 low‑temperature version) → Ballast management (VS6 cryo‑rated) → Auxiliary lube/fuel (OH2)

For engineering assistance, detailed pump sizing, or a quotation for any API 610 oil shipping pump (VS6, BB2, OH2, BB3, VS1), please contact info@hyrig.com. We respond within 24 hours.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code