Seawater lift pumps are critical for firewater systems, cooling water intake, and process water supply on offshore platforms, FPSOs, refineries, and desalination plants. The API 610 standard defines several pump types suitable for seawater duty. Below is a structured guide to the most relevant types, ranked by application priority, including their structural definition, seawater adaptability, typical applications, and representative models.
Structural Definition (API 610)
Vertically suspended, single‑case, diffuser bowl design. Impeller and bowl assembly submerged in seawater, connected to an above‑grade motor via a long drive shaft. Discharge through a column pipe.
Seawater Adaptability
Compact vertical footprint – ideal for space‑limited offshore platforms and FPSOs.
Multistage bowls deliver stable heads up to 2000 ft (610 m).
Wetted parts available in duplex or super duplex stainless steel for chloride corrosion resistance.
Typical Applications
Offshore platform firewater lift
FPSO seawater cooling intake
Near‑shore drilling rig seawater transfer
Representative Models
Sulzer SJT series, National Pump VS1 vertical turbine pump.
Structural Definition (API 610)
Motor and pump directly coupled as a single, fully submerged unit. No long shaft, no intermediate bearings. Single or multistage. Mounted via a top bracket to the sea chest or tank.
Seawater Adaptability
No long shaft wear or vibration – extremely low failure rate.
Maintenance interval ≥10,000 hours.
IP68 protection – permanent immersion in seawater.
Wetted parts in super duplex stainless steel (2507) – excellent chloride resistance.
Typical Applications
FPSO sea chest seawater intake
Deep‑sea drilling ship seawater lift
Large offshore engineering raw water supply
Representative Models
Sulzer SJS series submersible seawater pump, Inno Pumps VS6 vertical multistage pump.
Structural Definition (API 610)
Horizontal installation, axially split volute casing. Single‑stage, double‑suction impeller located between two bearing sets. High structural rigidity.
Seawater Adaptability
Double‑suction design provides very high flow rates (up to 25,000 gpm).
Low NPSH requirement – excellent cavitation resistance.
Axially split casing allows easy maintenance without disturbing piping – ideal for continuous operation.
Typical Applications
Land‑based refinery seawater circulation systems
Port and terminal seawater lift stations
Large seawater desalination plant intake
Representative Models
Sulzer HSA series, AxFlow BB1 double‑suction pump.
Structural Definition (API 610)
Submersible motor drive, vertically suspended. Single‑stage turbine bowl. No exposed drive shaft. Suitable for deep wells or deep tanks.
Seawater Adaptability
Submersion depth up to 15 metres – for moderate deep‑sea intake.
Simple construction, low maintenance cost.
Wetted parts can be specified in 316L or duplex stainless steel.
Typical Applications
Near‑shore platform emergency seawater lift
Offshore wind turbine platform cooling water intake
Representative Models
National Pump VS0 submersible vertical turbine pump.
Structural Definition (API 610)
Horizontal installation, radially split volute, single‑stage end suction. Impeller overhung from the bearing housing. Centreline support maintains alignment during thermal expansion.
Seawater Adaptability
Suitable for land‑based small to medium seawater lift (flow ≤800 m³/h, head ≤100 m).
Limited to moderate pressures (<36 bar) and flows (<2000 m³/h) due to overhung rigidity.
Typical Applications
Port firewater seawater pump station
Small desalination plant pretreatment intake
Representative Models
Sulzer CPN/CPT series, Alond Pumps OH2 centrifugal pump.
Structural Definition (API 610)
Horizontal installation, axially split casing. Multiple impellers in opposed arrangement, located between two bearing sets. Designed for high head.
Seawater Adaptability
Multistage design achieves very high heads (up to 10 MPa / 1450 psi).
Opposed impeller arrangement balances axial thrust – smooth operation.
Ideal for long‑distance seawater transmission or high‑pressure reverse osmosis feed.
Typical Applications
Seawater desalination high‑pressure RO feed
Long‑distance seawater transfer to offshore platforms
Representative Models
PumpWorks BB3 multistage pump, Boda BB3 series.
| API 610 Type | Mounting | Key Application Scenario | Flow Range | Head Range | Corrosion Protection Materials |
|---|---|---|---|---|---|
| VS1 | Vertical suspended | Offshore platforms / FPSO | 50 – 3500 m³/h | 20 – 1000 m | Duplex / Super duplex SS |
| VS6 | Submersible vertical | FPSO sea chest / deep sea intake | 300 – 2500 m³/h | 15 – 80 m | Super duplex 2507 |
| BB1 | Horizontal between‑bearing | Land‑based large flow intake | 100 – 10000 m³/h | 25 – 200 m | Duplex SS / Monel |
| VS0 | Submersible vertical | Near‑shore emergency lift | 5 – 500 m³/h | 10 – 140 m | 316L SS / Duplex |
| OH2 | Horizontal overhung | Land‑based small to medium | 50 – 800 m³/h | 25 – 100 m | 316 SS / Cast iron + coating |
| BB3 | Horizontal between‑bearing | High head seawater transfer | 50 – 500 m³/h | 100 – 1000 m | Super duplex SS |
Offshore / FPSO priority: VS series.
Choose VS1 for conventional seawater lift with above‑deck motor. Choose VS6 for submersible sea chest intake – eliminates long shaft and intermediate bearings.
Land‑based large flow: BB1.
For refineries, port stations, and continuous operation, BB1 double‑suction pumps provide high flow, low NPSH, and easy maintenance.
High head applications: BB3 or VS1.
For desalination high‑pressure feed or long‑distance transfer, select BB3 (horizontal multistage) or VS1 (vertical multistage).
Material compliance:
All seawater lift pumps must meet API 610 material classes (S‑8 / D‑1 / D‑2). Super duplex stainless steel (2507) or Monel is highly recommended for chloride corrosion resistance. Avoid standard austenitic stainless steels (304, 316) for prolonged seawater immersion.
For engineering support, detailed sizing, or a quotation for any API 610 seawater lift pump type, please contact info@hyrig.com. We respond within 24 hours.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.