HYRIG BB3 High Temperature High Pressure Coal Chemical Circulation Pump: API 610 radial split multi-stage between-bearing design. Flow 100-1200 m³/h, head 300-1800 m, temp up to 450°C, design pressure up to 300 bar. Handles abrasive slurries, high pressure hydrogen, CO, H2S, and synthesis gas. High temperature alloy construction, hardened wear surfaces, centerline mounted, API 682 tandem dry gas seal or dual seal with quench. Back pull-out cartridge rotor.

Conatct For Details
DetailReview(0)Additional

Product Overview
The HYRIG BB3 High Temperature High Pressure Coal Chemical Circulation Pump is a heavy-duty, multi-stage, radial split, between-bearing centrifugal pump, fully compliant with API 610 (ISO 13709) standards. Specifically engineered for extreme service in coal chemical plants – including coal gasification (Texaco, Shell, GSP), direct coal liquefaction (DCL), residue hydroconversion, and high pressure syngas cooling circulation – this pump features a centerline mounted casing and between-bearing rotor support with multi-stage diffuser hydraulics to achieve heads up to 1800 meters while handling abrasive, high temperature, high pressure, and chemically aggressive coal-derived streams.

Coal chemical circulation pumps operate at the frontiers of process severity: solids‑laden black water or slurry, high pressure hydrogen and CO, H₂S corrosion, temperatures approaching 500°C, and pressures up to 300 bar. The BB3 configuration, combined with specialty metallurgy and sealing systems, delivers the reliability, containment, and long service life required for continuous 24/7 coal chemical production.

Key Technical Parameters

  • Pump Type: API 610 BB3 Radial Split, Multi-Stage (3 to 12 stages), Between-Bearing Centrifugal Pump

  • Flow Range: 100 – 1200 m³/h (depending on gasifier or reactor capacity)

  • Head Range: 300 – 1800 m (higher with additional stages or higher speed)

  • Working Temperature: Up to 450°C (higher with Inconel or special alloys)

  • Design Pressure: Up to 300 bar (range from 100 bar to 300 bar for high pressure loops)

  • Structure: Centerline mounted casing, between-bearing dual support, radial split with cartridge style rotor

  • Seal Standard: API 682 mechanical seal – tandem dry gas seal (Plan 72+75) for high temperature, high pressure hydrogen+CO service, or Plan 53B pressurized dual seal with high temperature barrier fluid and Plan 62 quench for solids.

  • Materials (Alloy Selection): Chrome‑molybdenum steel (A217 WC6, WC9, C12A) for high temperature creep resistance; 12% chrome (CA-15) or 17-4 PH for impellers and diffusers; hardfaced stellited wear rings and bushings; optional Inconel 625 or Hastelloy C-276 for extreme corrosion/erosion.

  • Application: Coal gasification syngas cooler circulation pump, direct coal liquefaction high pressure recycle pump, residue hydroconversion loop, high temperature-high pressure slurry transfer, SNG (substitute natural gas) methanation loop.

Key Features

  • API 610 BB3 Compliance – Built to the most rigorous international standard for heavy duty, high energy, high severity continuous service.

  • Extreme High Pressure & High Head – Multi-stage design delivers up to 1800 m head and contains pressures up to 300 bar in a single casing, minimizing high pressure welds and flange leaks.

  • High Temperature Integrity – Centerline mounting allows thermal expansion without distortion; water jacketed bearing housings and thermal barrier zones protect bearings and seals up to 450°C process temperature.

  • Abrasion Resistance – Hardened stellited or tungsten carbide wear rings, throat bushings, and optional ceramic shaft sleeves to withstand coal char, ash, and catalyst fines.

  • Hydrogen & H₂S Resistance – Materials selected per NACE MR0175/ISO 15156; strict heat treatment and hardness control to prevent hydrogen embrittlement, HIC, and SOHIC.

  • Leak-Free Sealing – API 682 tandem dry gas seal (Plan 72 + Plan 75) provides zero process emissions of high pressure hydrogen and toxic gases. Quench (Plan 62) prevents solids accumulation on the atmospheric side.

  • Superior Rotor Dynamics – Between-bearing support with large diameter shafts, tilting pad journal bearings, and thrust balancing system for smooth operation at high speeds and under variable solids loading.

  • High Efficiency & Anti‑Coking – Optimized internal flow passages minimize stagnation and coking of heavy coal derived fractions; special surface treatments reduce deposits.

  • Easy Maintenance – Radial split cartridge design allows complete rotor and bearing replacement without disturbing the casing or piping, critical for planned turnarounds in coal chemical plants.

Typical Applications

  • Coal gasification unit syngas cooler circulation pump (high temperature, high pressure, solids laden)

  • Direct coal liquefaction (DCL) high pressure recycle pump (reactor loop)

  • High pressure black water circulation pump (gasification quench loop)

  • Residue hydroconversion and coal‑oil co‑processing unit recycle pump

  • High temperature hydrogenation loop in coal‑to‑chemicals (coal‑to‑olefins, coal‑to‑glycol)

  • Methanation loop recycle pump for SNG (substitute natural gas) production

Why HYRIG?
HYRIG combines advanced coal chemical engineering with decades of severe duty pumping experience. Each BB3 High Temperature High Pressure Coal Chemical Circulation Pump undergoes finite element analysis for pressure containment, thermal stress analysis for transient conditions, computational fluid dynamics for hydraulic optimization, rotordynamics analysis for vibration control, and seal support system integration per API 682. Our pumps are installed in leading coal gasification and direct liquefaction projects worldwide, delivering the uptime and safety required for the world’s most demanding coal chemical processes.

Contact Us
For technical quotation, material selection for your specific coal chemical service, or custom engineered solutions for your gasifier or liquefaction loop, please email us at: info@hyrig.com

Our engineering team will respond within 24 hours with a pump selection optimized for your circulating fluid composition, temperature, pressure, solids content, and flow requirements.