HYRIG BB4 High-Pressure Boiler Feed Water Pump – API 610 Horizontal Split Case Multi-Stage Between-Bearing Centrifugal Pump for Boiler Feed Service

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
HYRIG BB4 High-Pressure Boiler Feed Water Pump: API 610 horizontal split case multi-stage between-bearing design. Flow up to 2000 m³/h, head up to 3500 m (up to 14 stages), temp up to 200°C, design pressure up to 400 bar. Horizontal casing halves allow rotor access without removing piping. High efficiency hydraulics, heavy duty bearings, API 682 mechanical seal (Plan 21+62 or Plan 53B). Ideal for supercritical and ultra‑supercritical power plants.

Conatct For Details
DetailReview(0)Additional

Product Overview
The HYRIG BB4 High-Pressure Boiler Feed Water Pump is a heavy-duty, multi-stage, horizontal split case (axially split), between-bearing centrifugal pump, fully compliant with API 610 (ISO 13709) standards. Specifically engineered for high pressure boiler feed water (BFW) service in large utility power plants (supercritical and ultra‑supercritical), industrial steam generators, and high pressure water injection systems, this pump features a horizontal split casing (upper and lower half) which provides exceptional accessibility for maintenance without disturbing suction or discharge piping.

The BB4 horizontal split case design offers a significant advantage over radial split (BB3) pumps: the entire rotor assembly can be accessed by removing the upper casing half, enabling easy inspection, bearing replacement, and internal clearances adjustment – all without unbolting piping flanges. This pump delivers the extreme heads required for once‑through supercritical boilers and large steam drum systems, up to 3500 meters (350 bar discharge pressure). The BB4 configuration is the preferred choice for high energy, high availability power generation.

Key Technical Parameters

  • Pump Type: API 610 BB4 Horizontal Split Case, Multi‑Stage (4 to 14 stages), Between‑Bearing Centrifugal Pump

  • Flow Range: 100 – 2000 m³/h (higher upon request for large utility boilers)

  • Head Range: 800 – 3500 m (depending on boiler pressure and number of stages)

  • Working Temperature: Up to 200°C (up to 220°C with special seal plans)

  • Design Pressure: Up to 400 bar (compatible with supercritical boiler pressures)

  • Structure: Horizontal split case (axially split), between‑bearing dual support, with single suction or double suction first stage impeller for low NPSH.

  • Seal Standard: API 682 mechanical seal – typically Plan 21 (seal with integral cooler) + Plan 62 (quench) for high temperature BFW, or Plan 53B (pressurized dual seal) for zero emissions.

  • Materials: High strength chrome steel casing (ASTM A217 WC6, WC9, or C12A) for high temperature creep resistance; 12% chrome (CA‑15) or 410 stainless steel impellers; hardened stellited wear rings; shaft designed for cyclic duty.

  • Application: Main boiler feed pump for supercritical and ultra‑supercritical coal / gas power plants; large industrial boiler feed; high pressure water injection for oilfield and desalination.

Key Features

  • API 610 BB4 Compliance – Built to the highest international standard for continuous, high energy power plant pumps.

  • Horizontal Split Casing Accessibility – Upper casing half opens to expose the complete rotor, bearings, and seals without removing suction or discharge spool pieces, dramatically reducing maintenance time during scheduled outages.

  • Extreme High Head Capability – Up to 14 precision machined stages deliver heads exceeding 3500 meters, meeting the injection pressure of supercritical boilers in a single inline pump.

  • High Pressure Containment – Axially split casing designed with double flange bolts and high strength materials, hydrostatically tested to 1.5x maximum working pressure.

  • Low NPSH First Stage – Optional double suction first impeller or inducer minimizes required NPSH, allowing smaller deaerator elevation.

  • High Efficiency Hydraulics – Advanced diffuser and impeller vanes designed with computational fluid dynamics (CFD) to achieve up to 87% pump efficiency, significantly reducing power plant auxiliary load.

  • Thermal Stability – Centerline support feet integrated into the lower half casing maintain alignment during thermal transients.

  • Heavy Duty Rotor Dynamics – Between‑bearing design with short bearing span, precision balanced rotor (API 610 Grade G), tilting‑pad or high capacity rolling element bearings, and forced oil or oil mist lubrication for vibration‑free operation.

  • Reliable Sealing at High Temperature – API 682 Plan 21 cooles the stuffing box before the seal, then Plan 62 quench prevents coking; alternative Plan 53B for barrier fluid where zero leakage is mandated.

  • Ease of Inspection – The horizontal split allows internal wear ring and impeller clearance measurement without pulling the rotor from the casing – contractors and operators appreciate this in critical path outages.

Typical Applications

  • Main boiler feed pump for supercritical (240 bar) and ultra‑supercritical (>280 bar) coal‑fired power plants

  • Once‑through boiler circulation and feed control in combined cycle gas turbine (CCGT) plants

  • Large industrial boiler feed for chemical plants, refineries, and steel mills requiring pressures >150 bar

  • High pressure water injection for deep well oilfield secondary/tertiary recovery (waterflood >300 bar)

  • High pressure feed for seawater reverse osmosis (SWRO) desalination and energy recovery systems

Why HYRIG?
HYRIG combines power plant focused engineering with API 610 BB4 reliability. Each BB4 High Pressure Boiler Feed Water Pump is designed with horizontal split layout, CFD optimized multi‑stage hydraulics, finite element analysis for pressure case integrity, rotordynamics analysis for high speed stability, and API 682 seal support systems tailored to deaerated water at elevated temperatures. Our BB4 pumps are installed in hundreds of supercritical units worldwide, delivering the high availability and ease of maintenance required for 30+ year power plant operation.

Contact Us
For technical quotation, multistage hydraulic selection, or custom engineered solutions for your boiler feed or high pressure injection application, please email us at: info@hyrig.com

Our engineering team will respond within 24 hours with a pump selection optimized for your flow, head, boiler pressure, and maintenance access requirements.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit