Product Overview
The HYRIG BB4 Lean Amine Booster Pump is a heavy-duty, multi-stage, horizontal split (axially split) casing, between-bearing centrifugal pump, fully compliant with API 610 (ISO 13709) standards. Specifically engineered for lean amine booster service – pumping regenerated lean amine (MDEA, DEA, MEA) from the stripper back to the high pressure absorber column – this pump delivers the head capability of a multistage pump with the maintainability of a split case design.
The horizontal split casing allows the top half to be removed without disconnecting suction or discharge piping, providing full access to the rotor, bearings, wear rings, and interstage bushings. This feature significantly simplifies periodic inspection and maintenance in amine service, where seal and bearing checks are routine.
The HYRIG BB4 solves common lean amine challenges: low NPSH at regenerator outlet, high absorber pressure requiring >400 m head, seal leakage emissions, vibration during turndown, and corrosion from heat stable salts.
Key Technical Parameters
Pump Type: API 610 BB4 Horizontal Split (Axially Split), Multi‑Stage (2 to 8 stages), Between‑Bearing Centrifugal Pump
Flow Range: 80 – 2000 m³/h
Head Range: 150 – 800 m (higher with additional stages)
Working Temperature: Up to 120°C
Design Pressure: Up to 50 bar
Structure: Horizontal split casing (upper and lower halves), centerline mounted, dual heavy duty bearings, rotor accessible with top casing removed
Seal Standard: API 682 – Plan 53B (pressurized dual seal) with compatible barrier fluid; Plan 11+62 optional
Materials: 316L stainless steel wetted parts (standard) – upper and lower casing halves, impellers, diffusers; carbon steel casing with 316L trim available. NACE MR0175 optional.
Application: Lean amine booster pump for natural gas sweetening, refinery tail gas treating (TGTU), CO₂ capture, biogas upgrading, and other high head amine circulation duties.
Technical Challenges & Solutions for Lean Amine Service
| Challenge | HYRIG BB4 Solution |
|---|---|
| Low NPSH at regenerator outlet | First stage double suction impeller or inducer – reduces NPSH3 by up to 50% |
| High absorber pressure (50‑80 bar) requiring >400 m head | 4 to 8 stages in a single horizontal split casing |
| Seal leakage / VOC emissions | API 682 Plan 53B dual pressurized seal – zero emissions; barrier fluid compatible with amine |
| Vibration during turndown | Between-bearing short span + CFD optimized diffusers + optional tilting pad bearings – stable from 40% to 110% of BEP |
| Corrosion from heat stable salts | Full 316L wetted parts (upper & lower casing, impellers, diffusers) – maximum corrosion resistance |
| Long maintenance outages | Horizontal split design: top casing removed quickly for access to bearings, seals, wear rings without rotor extraction |
| Extended service life | Hardened stellited wear rings + large diameter shaft + oil mist lubrication – field proven long MTBR |
Case Study Snapshot – Large Gas Sweetening Plant, Middle East
Application: Lean MDEA booster from regenerator to 72 bar absorber. Flow 1600 m³/h, head 620 m.
HYRIG BB4 solution: Single BB4 unit with double suction first stage, 6 stages, 316L wetted parts, Plan 53B seal.
Results after 3 years:
No unscheduled downtime
Typical inspection turnaround: 6 hours (top casing off, wear rings measured, seal replaced, closed)
Vibration <2.0 mm/s
Projected service life >8 years before major overhaul
Full case study available upon request.
Key Features – BB4 Advantage
API 610 BB4 Compliance – Built to the highest standard for continuous, reliable amine service.
Horizontal Split for Maintainability – Remove top half casing without disturbing suction/discharge piping. Full access to rotor, bearings, wear rings, and interstage seals. Reassembly is repeatable with dowel pins – no realignment needed.
Multi-Stage High Head – Up to 8 stages produce up to 800 m head, covering high pressure absorber requirements.
Low NPSH Capability – Double suction first impeller option reduces required NPSH by 40-50% – ideal for regenerator bottom conditions.
Zero Fugitive Emissions – API 682 Plan 53B seal with accumulator/reservoir; barrier fluid (water/glycol or amine-compatible synthetic) ensures no amine leakage to atmosphere.
Corrosion Resistance – 316L stainless steel wetted parts standard; Super Duplex available for high chloride / offshore amine systems.
High Efficiency Hydraulics – CFD designed multistage diffuser/impeller combinations achieve 84-87% efficiency, reducing energy cost in continuous 24/7 operation.
Heavy Duty Rotor Dynamics – Between-bearing short span, large diameter shaft, tilting pad or multi‑lobe bearings, oil mist or forced oil lubrication.
Simplified Seal & Bearing Access – Bearings and mechanical seal can be replaced with casing top half removed, without rotor extraction – further reduces maintenance downtime.
Lifecycle Support – Free 3D CAD models, API 610 datasheet, selection software. Field service for alignment and vibration analysis.
Typical Applications
Large natural gas sweetening plants (>500 MMSCFD) – lean MDEA booster to high pressure contactor
Refinery tail gas treating unit (TGTU) – lean amine circulation requiring high head and routine maintenance access
Post‑combustion CO₂ capture (large scale, 1 million tonnes/year and above) – MEA or advanced amine blends
Offshore gas platforms where maintenance space is limited – horizontal split simplifies internal inspection without long rotor extraction
Biogas upgrading to biomethane – high pressure amine wash with easy maintainability
Why HYRIG BB4 for Lean Amine?
HYRIG BB4 pumps are designed specifically for lean amine booster services where maintenance access, corrosion resistance, and high head efficiency are critical. The horizontal split casing reduces the complexity of internal inspections, while 316L metallurgy provides long-term resistance to heat stable salts. With API 682 Plan 53B sealing, emissions are eliminated. HYRIG offers:
Fast, predictable maintenance – top casing removal without pipe disturbance
Full API 610 compliance
Corrosion engineered materials
Global service support
Download Resources
Request the following from our technical team:
BB4 Lean Amine Pump Selection Guide (PDF) – includes head/flow curves for 2/4/6/8 stages
API 682 Plan 53B P&ID for Amine Service (PDF)
Case Study Pack – real BB4 installations with performance data
3D CAD model (STEP) for plant layout integration
API 610 Datasheet template (Excel)
Contact: info@hyrig.com – subject line “BB4 Amine Inquiry”
Contact Us
For technical quotation, specification review, or to request maintenance planning support for your lean amine booster duty, please email us at: info@hyrig.com
Our engineering team will respond within 24 hours with a pump selection optimized for your lean amine flow, absorber pressure, amine type, NPSH, and maintenance interval requirements.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.