This page presents verified field cases of BB3 horizontal multistage centrifugal pumps operating successfully in demanding industrial environments. Each case demonstrates the pump's high pressure capability, continuous-duty reliability, and adaptability to different fluids and conditions.
Case 1 – Oilfield Water Injection Project (Middle East)
Background: A national oil company needed a high-pressure water injection pump for secondary oil recovery. Operating condition: 24/7 continuous, outdoor desert environment, high ambient temperature, and need for low maintenance.
BB3 Pump Solution:
Flow: 280 m³/h
Head: 1800 m
Speed: 2980 rpm
Material: Duplex stainless steel casing + 17-4PH impeller
Seal: API 682 Plan 53B mechanical seal
Result:
Stable water injection pressure maintained within ±2%
Continuous running for over 4 years without major overhaul
Low failure rate, easy annual inspection via horizontal split casing design
Site pictures and 3-year operation log available upon request
Case 2 – Power Plant Boiler Feed System (Southeast Asia)
Background: A 150 MW coal-fired power plant required a replacement for an existing BB4 barrel pump that had high maintenance costs and long downtime.
BB3 Pump Solution:
Flow: 210 m³/h
Head: 1400 m
Temperature: 158°C
Material: Carbon steel casing + 316L stainless steel impeller
Seal: High-temperature mechanical seal with cooling flush
Result:
Meets full load operation from 50% to 100% of plant capacity
Higher efficiency (+5%) than the replaced BB4 pump in this medium flow range
Maintenance downtime reduced by 60% due to axial split design (no need to remove piping)
Running data shows stable flow and vibration well within API limits
Case 3 – Chemical Factory Process Water Line (China)
Background: A chemical plant needed to transfer slightly corrosive process water across 3.5 km distance with elevation gain. Existing single-stage pumps could not achieve required head.
BB3 Pump Solution:
Flow: 350 m³/h
Head: 520 m
Material: 316L stainless steel for all wetted parts (casing, impeller, shaft, wear rings)
Seal: Single mechanical seal, PTFE gaskets
Result:
Solved long-distance pressurization delivery problem
Custom material resists corrosion from chlorides and low pH
Easy maintenance during annual plant shutdown – upper casing removed in 2 hours
Client ordered two additional BB3 pumps for other process lines
What You Can Request From Us for Each Case
Site pictures and installation photos
Project parameter sheet (flow, head, power, materials, seal plan)
Actual running data (pressure trend, vibration, temperature, power consumption)
User feedback or maintenance log (where available)
Why Project Cases Matter for Your Selection
Real field references prove that BB3 pumps deliver:
✔ Long continuous operation (years, not months)
✔ Low failure rate in harsh environments
✔ Easy maintenance without piping removal
✔ Custom material suitability for slightly corrosive or clean fluids
Get the Complete Case Study Package
We can match your operating conditions to similar successful projects. Request the BB3 pump project case PDF or ask for references in your industry.
Email: info@hyrig.com
Please specify your industry (oil & gas / power plant / chemical / water treatment) and we will send relevant case studies, photographs, and technical data within 24 hours.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.