API 610 BB2 horizontal, axially split, multistage pump for boiler forced circulation service. Designed for high temperature (up to 350°C), high pressure, and continuous operation. Suitable for drum-type and once-through boilers. High reliability, easy maintenance. China BB2 pump manufacturer.

Conatct For Details
DetailReview(0)Additional

A boiler circulation pump (also called forced circulation pump) is used in drum-type or once‑through boilers to circulate boiler water through evaporator loops, ensuring uniform heat transfer and preventing tube overheating. This service demands a pump capable of handling high temperature (typically 250‑350°C), high pressure (up to 200 bar or more), and continuous duty. Our API 610 BB2 multistage, axially split, between‑bearings pump is specifically engineered for this severe service. This design fully complies with API 610 11th/12th edition (ISO 13709) .

Structure match check: API 610 BB2 is defined as a horizontal, axially split, multistage, between‑bearings pump with centerline support for high temperature. This matches boiler circulation requirements because:

  • Axially split casing allows removal of the top half for internal inspection and replacement of stage pieces without disturbing suction/discharge piping – essential for high‑availability continuous operation.

  • Multistage design (typically 2-8 stages) provides the high heads required to overcome pressure drops through the evaporator circuits (heads often 150‑500 m).

  • Between‑bearings rotor offers superior stiffness, critical for high‑speed operation and high radial loads from hot, high‑density water.

  • Centerline support accommodates thermal expansion at 350°C without misalignment.

  • Wetted materials suitable for high‑temperature demineralized water (often with pH control) – typically carbon steel with stainless steel or alloy trim.

Why API 610 BB2 for boiler circulation duty?

  • High temperature capability – Designed for continuous operation up to 350°C (with appropriate materials). Centerline support, water‑cooled bearing housings, and high‑temperature grade carbon steel (WC6, WC9) or alloy steel.

  • High pressure – BB2 construction can handle discharge pressures up to 200 bar or more, suitable for high‑pressure drum boilers and once‑through supercritical boilers.

  • High efficiency – Multistage axially split design minimizes recirculation losses, achieving 80‑86% efficiency at design point, saving significant energy.

  • Easy maintenance – Axially split casing allows full access to internals (impellers, diffusers, wear rings) without removing the pump from the line. Interstage bushings and balance drum are accessible.

  • Reliable sealing – API 682 mechanical seals with Plan 23 (cooled recirculation) for high‑temperature water. Tandem or double seals with barrier fluid to prevent flashing at seal faces.

  • Long life – Heavy duty bearings (tilting pad or multi‑lobe), conservatively sized shaft, and hardened wear ring materials (Stellite) ensure high MTBR.

Key design features for boiler circulation service

  • Casing – Axially split, centerline support. Material: WC6 (1% Cr, 0.5% Mo) for up to 450°C, or WC9 (2.25% Cr, 1% Mo) for higher creep strength. Pressure rating: ASME Class 600 to 1500 depending on discharge pressure.

  • Impellers – Closed, radial, dynamically balanced. First stage often double‑suction to reduce NPSHr. Hardened 12% chrome (CA6NM) or 17-4PH for wear resistance. Each stage with replaceable wear rings.

  • Diffusers – Stationary guide vanes that convert velocity to pressure. Also hardened stainless steel.

  • Shaft – Through‑shaft design with keys or hydraulic fit. Material: AISI 4140, 17-4PH, or 12% chrome, hardened.

  • Axial thrust management – Balance drum or opposed impeller arrangement. Balance drum is typical with return line to suction. Optional double‑acting thrust bearing.

  • Bearings – Tilting pad or multi‑lobe journal bearings for high speeds and loads. Thrust bearing: double acting Kingsbury type. For high temperatures, bearing housings are water‑cooled (cooling coils). Pure oil mist lubrication standard.

  • Sealing – API 682 Plan 23 (cooled recirculation through seal housing heat exchanger) keeps seal faces below boiling point. For high pressure, tandem seals with Plan 52 (unpressurized buffer) or Plan 53A (pressurized barrier). Seal faces: SiC vs. SiC or SiC vs. carbon.

  • NPSH – Boiler circulation pumps typically have adequate NPSH from steam drum or pressurizer. However, first stage double‑suction or inducer optional for low NPSH situations.

  • Materials for hot water – All wetted surfaces that contact boiler water (typically demineralized water with ammonia/hydrazine pH 9‑10) must be corrosion resistant. Carbon steel is acceptable; stainless steel clad on wear surfaces.

  • Flushing connections – For pre‑heating and cool down before maintenance. Steam inlet and outlet for casings to bring pump to operating temperature slowly.

Typical performance range

ParameterValue
Flow rate50 – 3000 m³/h
Head150 – 800 m
TemperatureUp to 350°C (higher with alloy)
Discharge pressureUp to 250 bar
Speeds1450 / 2900 / 3600 rpm (VSD optional)
Stages2 to 8

Typical applications

  • Drum‑type boiler forced circulation (natural circulation assisted with pump).

  • Once‑through (universal pressure) boilers – circulation at start‑up and low load.

  • Heat recovery steam generator (HRSG) – high pressure evaporator circulation.

  • Industrial water‑tube boilers – boiler water recirculation.

  • Nuclear reactor coolant loops (low‑temperature side) – though special nuclear grade required.

Why choose our API 610 BB2 boiler circulation pump?

  • Full API 610 compliance – Type BB2 verified. Performance test, 4‑hour mechanical run test with thermal stabilization.

  • High temperature engineered – Centerline support, water‑cooled bearings, Plan 23 seals, and WC6 casings.

  • High efficiency – Multistage hydraulics reduce power consumption – critical for MW‑scale boiler pumps.

  • Easy internal access – Axially split casing simplifies inspection and part replacement without pipe removal.

  • Short lead time – Standard frame sizes with WC6 casings available 20‑24 weeks; custom materials slightly longer.

  • Global spare parts support – Impellers, diffusers, shafts, wear rings, balance drums, bearings, seal cartridges shipped worldwide.

Quality assurance

  • ISO 9001:2015 certified.

  • API 610 mechanical run test (4 hours) with vibration and bearing temperature monitoring at simulated operating temperature (if possible).

  • Hydrostatic test of casing at 1.5× working pressure.

  • Material traceability EN 10204 3.1 / 3.2, including elevated temperature mechanical properties.

  • NDE – MT, PT, UT, RT as required.

  • Impeller and rotor dynamic balancing grade G1.0 for high speed service.

How to specify your boiler circulation pump

Please provide: flow (m³/h), head (m), operating temperature (°C), drum pressure (bar), NPSHa (m), boiler water chemistry (pH, conductivity, oxygen level), required material (WC6/WC9/other), and any limit on pump speed. We will recommend number of stages, first stage type (single or double suction), thrust balancing method, seal plan (23/52/53A), bearing arrangement, and driver details.

Contact us

For a quotation or technical discussion on boiler circulation pumps (API 610 BB2) :

info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit