Booster Pump OH2 Model Selection – Complete API 610 Series Technical Specifications

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Booster Pump OH2 Model Selection – Complete API 610 Series Technical Specifications is a comprehensive guide to heavy-duty, centerline-mounted, radially split centrifugal pumps for pressure boosting in pipelines, process systems, tank farms, and long‑distance transfer, featuring 20 models from 40-250 to 150-400, high‑head hydraulic design (up to 400 m), low NPSHr (≤2.0 m, inducer to ≤1.0 m), API 682 Type 22 double seals with Plan 53A (leakage ≤1 ppm), heavy‑duty casing (design pressure up to 100 bar), and capacity/head ranges up to 550 m³/h and 360 m.

Conatct For Details
DetailReview(0)Additional

1. Product Overview

The OH2 Series Booster Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 12th Edition (ISO 13709) international standards. Its primary function is to raise the pressure at the inlet of pipelines or equipment, solving issues such as insufficient pressure, limited transmission distance, and elevation constraints. It is widely used in petrochemical, natural gas, power plants, long‑distance pipelines, process system boosting, tank farm backflow prevention, and equipment pre‑pressurization. The pump handles a wide range of media including clean or slightly solids‑laden fluids, neutral or corrosive, low‑temperature to high‑temperature, and flammable/explosive liquids (e.g., natural gas liquids, crude oil, diesel, solvents, water). It achieves long‑term continuous operation (≥8,000 hours/year, annual availability ≥99.5%) and is a critical equipment for pressure boosting applications.

Model Code Interpretation (OH2):

  • O = Overhung: Impeller outside bearing housing – compact structure, facilitates high‑pressure sealing.

  • H = Horizontal: Horizontal mounting, compatible with booster system layouts.

  • 2 = 2nd Generation: Centerline support design – superior thermal stability for high‑temperature, high‑pressure service.

Key API 610 Compliance Features:

  • Centerline mounting per API 610 9.1.1.1 – no rear bracket, free axial expansion.

  • Back pull-out design (DBSE per API 610 9.1.1.2) – rotor removal without disconnecting piping or motor.

  • High‑pressure hydraulic design – optimized for large differential pressure, high efficiency, and low NPSH.

2. Key Structural Features (Booster‑Specific Design)

2.1 High‑Pressure Hydraulic Design (Large Differential Pressure, High Efficiency)

  • High‑head closed impeller, specific speed n_s = 80–150 – suitable for high differential pressure, low flow coefficient service.

  • Double volute (≥DN80) to balance radial forces – vibration ≤2.0 mm/s, stable operation under high pressure.

  • Flow path hardening + wear‑resistant coating – resists high‑pressure erosion, extends service life.

  • Low NPSHr: standard ≤2.0 m; optional inducer reduces NPSHr to ≤1.0 m – suitable for low inlet pressure conditions.

2.2 Centerline Support + Heavy‑Duty Casing (High Pressure & Thermal Stability)

  • Centerline mounting – symmetrical thermal deformation under high temperature and pressure, maintains alignment – shaft runout ≤0.02 mm.

  • Thick‑walled casing – design pressure 50 bar (standard) / 100 bar (optional); flange loading 2× API.

  • Back pull‑out design – allows rotor removal without disconnecting piping – fast maintenance.

2.3 High‑Pressure Sealing System (API 682 + Leak‑Tight)

  • Standard: API 682 Type 22 double mechanical seals. Friction pairs: SiC vs carbon graphite.

  • Flush plans: Plan 53A (pressurized isolation fluid) or Plan 54 (forced cooling) – stable seal chamber under high pressure.

  • O‑rings: FFKM – temperature range -20°C to 220°C, swell‑resistant.

  • Leakage control: ≤1 ppm – compliant with high‑pressure explosion‑proof and environmental requirements.

2.4 Heavy‑Duty Bearings + Rigid Shaft (High Pressure Vibration Resistance)

  • SFI ≤0.25 rigid shaft per API 610 Appendix K – low deflection and vibration under high pressure.

  • Heavy‑duty bearing housing with independent cooling (water or air cooled) – oil temperature ≤70°C. Oil mist lubrication – bearing life ≥40,000 hours.

3. General Technical Specifications (Booster‑Specific Parameters)

ParameterTypical Range
Capacity5 – 2,600 m³/h (customizable to 3,000 m³/h)
Head50 – 360 m (max. 1,180 ft); high‑pressure version to 400 m
Operating Temperature-40°C to 200°C (standard); up to 425°C with cooling structure
Inlet Pressure0.05 – 2.0 MPa
Outlet Pressure2.0 – 10.0 MPa (standard 5.0 MPa)
Differential Pressure1.5 – 8.0 MPa
Material OptionsCarbon steel (WCB), 304/316L, duplex steel, chrome‑moly steel
NPSHr≤2.0 m (≤1.0 m with inducer)
Speed50Hz: 1,450/2,900 rpm; 60Hz: 1,750/3,500 rpm
Flange RatingClass 150/300/600# (RF, ASME B16.5) – up to Class 900/1500 optional
StandardsAPI 610 12th, API 682, NACE MR0175/ISO 15156

4. Global Equivalent Models (API 610 OH2 for Booster)

BrandSeries / ModelsKey Adaptation
SulzerOHH 50-315, 80-315, 100-400High‑differential pressure, inducer option, carbon steel/316L
FlowserveHPX 350, 450, 600Petrochemical pipeline booster, Plan 53A flush, Ex d IIB T4
KSBKZE 65-315, 100-315Long‑distance pipeline, low NPSH (≤1.5 m), heavy‑wall casing
EbaraCWA/CSW seriesPower plant boiler feed pre‑stage, double volute, 425°C capability

5. Complete OH2 Booster Pump Model Lineup (20 Core Models by Size)

Small Bore (DN40/DN50 – Small Flow, High Pressure)

ModelDefinitionCapacity/HeadPowerApplication
Booster Pump 40-250 OH2API 610 OH2, DN40, 250mm impeller, high pressure small flow25–50 m³/h / 80–110 m18.5 kWSmall pipeline pressurization, skid‑mounted booster
Booster Pump 40-315 OH2DN40, 315mm impeller, ultra‑high head20–45 m³/h / 120–160 m30 kWHigh‑pressure injection, tank farm backflow prevention
Booster Pump 50-160 OH2DN50, 160mm impeller, general small flow30–60 m³/h / 35–50 m11 kWLow‑pressure boost, equipment pre‑pressurization
Booster Pump 50-200 OH2DN50, 200mm impeller, standard30–65 m³/h / 50–70 m15 kWMedium‑pressure transfer, small pipeline intermediate boost
Booster Pump 50-250 OH2DN50, 250mm impeller, high pressure30–65 m³/h / 80–115 m22 kWTank farm backflow, high‑head booster

Medium Bore (DN65/DN80 – Mainstream Booster Service)

ModelDefinitionCapacity/HeadPowerApplication
Booster Pump 65-160 OH2DN65, 160mm impeller, medium flow low pressure50–100 m³/h / 32–48 m18.5 kWProcess line pre‑pressurization, heat exchanger feed
Booster Pump 65-200 OH2DN65, 200mm impeller, medium flow general50–110 m³/h / 48–72 m30 kWRefinery intermediate booster, pipeline branch pressurization
Booster Pump 65-250 OH2DN65, 250mm impeller, medium flow high pressure50–110 m³/h / 75–115 m45 kWLong‑distance pipeline booster, tank farm export
Booster Pump 65-315 OH2DN65, 315mm impeller, medium flow ultra‑high head45–100 m³/h / 120–180 m55 kWHigh‑pressure process system, reactor feed stabilizer
Booster Pump 80-160 OH2DN80, 160mm impeller, large flow low pressure80–160 m³/h / 30–48 m37 kWCooling water boost, utility system pressurization
Booster Pump 80-200 OH2DN80, 200mm impeller, main duty80–160 m³/h / 48–72 m55 kWPlant‑wide pressure boosting, distribution main
Booster Pump 80-250 OH2DN80, 250mm impeller, large flow medium‑high pressure80–160 m³/h / 80–120 m75 kWLong‑distance trunk line intermediate booster
Booster Pump 80-315 OH2DN80, 315mm impeller, large flow high pressure75–150 m³/h / 120–180 m132 kWHigh‑pressure pipeline network, refinery process booster

Large Bore (DN100/DN125/DN150 – Large Flow, High Pressure)

ModelDefinitionCapacity/HeadPowerApplication
Booster Pump 100-200 OH2DN100, 200mm impeller, very large flow120–220 m³/h / 45–70 m75 kWLarge plant pressure boosting, main pipeline pressurization
Booster Pump 100-250 OH2DN100, 250mm impeller, very large flow medium pressure120–220 m³/h / 70–110 m160 kWCross‑country pipeline booster, crude oil main line
Booster Pump 100-315 OH2DN100, 315mm impeller, very large flow high pressure120–220 m³/h / 110–160 m160 kWPetrochemical complex pressurization, refinery main booster
Booster Pump 100-400 OH2DN100, 400mm impeller, very large flow ultra‑high head110–210 m³/h / 180–240 m315 kWUltra‑high pressure injection, mountain pipeline booster
Booster Pump 125-250 OH2DN125, 250mm impeller, giant flow200–350 m³/h / 80–120 m200 kWLarge tank farm export, national pipeline network booster
Booster Pump 125-315 OH2DN125, 315mm impeller, giant flow high pressure200–350 m³/h / 110–160 m315 kWMega‑refinery main booster, cross‑border pipeline
Booster Pump 150-315 OH2DN150, 315mm impeller, extra‑large flow300–550 m³/h / 90–140 m450 kWWorld‑scale pipeline booster, power plant circulating water pressurization
Booster Pump 150-400 OH2DN150, 400mm impeller, top large flow high pressure300–550 m³/h / 160–220 m630 kWUltra‑large oil/gas pipeline, high‑pressure injection station

6. Selection Notes (Booster‑Specific – Critical)

  • Differential pressure priority: Select based on maximum differential pressure. Add 10–20% capacity margin to avoid overload.

  • Cavitation control: Must have NPSHa ≥ NPSHr + 2.5 m (≥3.0 m for low inlet pressure). Add inducer or booster tank if needed.

  • Material selection: Carbon steel for neutral media; 316L/duplex for chlorides/corrosive service; chrome‑moly for high temperature (>200°C).

  • Seal matching: For discharge pressure ≥5 MPa, double seals + Plan 53A are mandatory. Flammable/explosive media require explosion‑proof motor and static grounding.

  • Operating range: Keep operating point within high‑efficiency zone (design flow ±15%) to avoid low‑flow overheating and high‑flow cavitation.

7. Contact Us

For detailed technical datasheets, model selection assistance (free selection report with inlet/outlet pressures, flow, media properties, temperature), 3D models (STEP/IGES), certification documents (API 610, ATEX/IECEx, NACE MR0175), and customized solutions (high‑differential pressure, high‑temperature, low‑NPSH inducer), please contact:

Email: info@hyrig.com

Our engineering team responds within 24 hours with API 610 compliant solutions tailored to your pressure boosting and high‑head transfer needs.



Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit