1. Product Overview
The OH2 Series Booster Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 12th Edition (ISO 13709) international standards. Its primary function is to raise the pressure at the inlet of pipelines or equipment, solving issues such as insufficient pressure, limited transmission distance, and elevation constraints. It is widely used in petrochemical, natural gas, power plants, long‑distance pipelines, process system boosting, tank farm backflow prevention, and equipment pre‑pressurization. The pump handles a wide range of media including clean or slightly solids‑laden fluids, neutral or corrosive, low‑temperature to high‑temperature, and flammable/explosive liquids (e.g., natural gas liquids, crude oil, diesel, solvents, water). It achieves long‑term continuous operation (≥8,000 hours/year, annual availability ≥99.5%) and is a critical equipment for pressure boosting applications.
Model Code Interpretation (OH2):
O = Overhung: Impeller outside bearing housing – compact structure, facilitates high‑pressure sealing.
H = Horizontal: Horizontal mounting, compatible with booster system layouts.
2 = 2nd Generation: Centerline support design – superior thermal stability for high‑temperature, high‑pressure service.
Key API 610 Compliance Features:
Centerline mounting per API 610 9.1.1.1 – no rear bracket, free axial expansion.
Back pull-out design (DBSE per API 610 9.1.1.2) – rotor removal without disconnecting piping or motor.
High‑pressure hydraulic design – optimized for large differential pressure, high efficiency, and low NPSH.
2. Key Structural Features (Booster‑Specific Design)
2.1 High‑Pressure Hydraulic Design (Large Differential Pressure, High Efficiency)
High‑head closed impeller, specific speed n_s = 80–150 – suitable for high differential pressure, low flow coefficient service.
Double volute (≥DN80) to balance radial forces – vibration ≤2.0 mm/s, stable operation under high pressure.
Flow path hardening + wear‑resistant coating – resists high‑pressure erosion, extends service life.
Low NPSHr: standard ≤2.0 m; optional inducer reduces NPSHr to ≤1.0 m – suitable for low inlet pressure conditions.
2.2 Centerline Support + Heavy‑Duty Casing (High Pressure & Thermal Stability)
Centerline mounting – symmetrical thermal deformation under high temperature and pressure, maintains alignment – shaft runout ≤0.02 mm.
Thick‑walled casing – design pressure 50 bar (standard) / 100 bar (optional); flange loading 2× API.
Back pull‑out design – allows rotor removal without disconnecting piping – fast maintenance.
2.3 High‑Pressure Sealing System (API 682 + Leak‑Tight)
Standard: API 682 Type 22 double mechanical seals. Friction pairs: SiC vs carbon graphite.
Flush plans: Plan 53A (pressurized isolation fluid) or Plan 54 (forced cooling) – stable seal chamber under high pressure.
O‑rings: FFKM – temperature range -20°C to 220°C, swell‑resistant.
Leakage control: ≤1 ppm – compliant with high‑pressure explosion‑proof and environmental requirements.
2.4 Heavy‑Duty Bearings + Rigid Shaft (High Pressure Vibration Resistance)
SFI ≤0.25 rigid shaft per API 610 Appendix K – low deflection and vibration under high pressure.
Heavy‑duty bearing housing with independent cooling (water or air cooled) – oil temperature ≤70°C. Oil mist lubrication – bearing life ≥40,000 hours.
3. General Technical Specifications (Booster‑Specific Parameters)
| Parameter | Typical Range |
|---|---|
| Capacity | 5 – 2,600 m³/h (customizable to 3,000 m³/h) |
| Head | 50 – 360 m (max. 1,180 ft); high‑pressure version to 400 m |
| Operating Temperature | -40°C to 200°C (standard); up to 425°C with cooling structure |
| Inlet Pressure | 0.05 – 2.0 MPa |
| Outlet Pressure | 2.0 – 10.0 MPa (standard 5.0 MPa) |
| Differential Pressure | 1.5 – 8.0 MPa |
| Material Options | Carbon steel (WCB), 304/316L, duplex steel, chrome‑moly steel |
| NPSHr | ≤2.0 m (≤1.0 m with inducer) |
| Speed | 50Hz: 1,450/2,900 rpm; 60Hz: 1,750/3,500 rpm |
| Flange Rating | Class 150/300/600# (RF, ASME B16.5) – up to Class 900/1500 optional |
| Standards | API 610 12th, API 682, NACE MR0175/ISO 15156 |
4. Global Equivalent Models (API 610 OH2 for Booster)
| Brand | Series / Models | Key Adaptation |
|---|---|---|
| Sulzer | OHH 50-315, 80-315, 100-400 | High‑differential pressure, inducer option, carbon steel/316L |
| Flowserve | HPX 350, 450, 600 | Petrochemical pipeline booster, Plan 53A flush, Ex d IIB T4 |
| KSB | KZE 65-315, 100-315 | Long‑distance pipeline, low NPSH (≤1.5 m), heavy‑wall casing |
| Ebara | CWA/CSW series | Power plant boiler feed pre‑stage, double volute, 425°C capability |
5. Complete OH2 Booster Pump Model Lineup (20 Core Models by Size)
Small Bore (DN40/DN50 – Small Flow, High Pressure)
| Model | Definition | Capacity/Head | Power | Application |
|---|---|---|---|---|
| Booster Pump 40-250 OH2 | API 610 OH2, DN40, 250mm impeller, high pressure small flow | 25–50 m³/h / 80–110 m | 18.5 kW | Small pipeline pressurization, skid‑mounted booster |
| Booster Pump 40-315 OH2 | DN40, 315mm impeller, ultra‑high head | 20–45 m³/h / 120–160 m | 30 kW | High‑pressure injection, tank farm backflow prevention |
| Booster Pump 50-160 OH2 | DN50, 160mm impeller, general small flow | 30–60 m³/h / 35–50 m | 11 kW | Low‑pressure boost, equipment pre‑pressurization |
| Booster Pump 50-200 OH2 | DN50, 200mm impeller, standard | 30–65 m³/h / 50–70 m | 15 kW | Medium‑pressure transfer, small pipeline intermediate boost |
| Booster Pump 50-250 OH2 | DN50, 250mm impeller, high pressure | 30–65 m³/h / 80–115 m | 22 kW | Tank farm backflow, high‑head booster |
Medium Bore (DN65/DN80 – Mainstream Booster Service)
| Model | Definition | Capacity/Head | Power | Application |
|---|---|---|---|---|
| Booster Pump 65-160 OH2 | DN65, 160mm impeller, medium flow low pressure | 50–100 m³/h / 32–48 m | 18.5 kW | Process line pre‑pressurization, heat exchanger feed |
| Booster Pump 65-200 OH2 | DN65, 200mm impeller, medium flow general | 50–110 m³/h / 48–72 m | 30 kW | Refinery intermediate booster, pipeline branch pressurization |
| Booster Pump 65-250 OH2 | DN65, 250mm impeller, medium flow high pressure | 50–110 m³/h / 75–115 m | 45 kW | Long‑distance pipeline booster, tank farm export |
| Booster Pump 65-315 OH2 | DN65, 315mm impeller, medium flow ultra‑high head | 45–100 m³/h / 120–180 m | 55 kW | High‑pressure process system, reactor feed stabilizer |
| Booster Pump 80-160 OH2 | DN80, 160mm impeller, large flow low pressure | 80–160 m³/h / 30–48 m | 37 kW | Cooling water boost, utility system pressurization |
| Booster Pump 80-200 OH2 | DN80, 200mm impeller, main duty | 80–160 m³/h / 48–72 m | 55 kW | Plant‑wide pressure boosting, distribution main |
| Booster Pump 80-250 OH2 | DN80, 250mm impeller, large flow medium‑high pressure | 80–160 m³/h / 80–120 m | 75 kW | Long‑distance trunk line intermediate booster |
| Booster Pump 80-315 OH2 | DN80, 315mm impeller, large flow high pressure | 75–150 m³/h / 120–180 m | 132 kW | High‑pressure pipeline network, refinery process booster |
Large Bore (DN100/DN125/DN150 – Large Flow, High Pressure)
| Model | Definition | Capacity/Head | Power | Application |
|---|---|---|---|---|
| Booster Pump 100-200 OH2 | DN100, 200mm impeller, very large flow | 120–220 m³/h / 45–70 m | 75 kW | Large plant pressure boosting, main pipeline pressurization |
| Booster Pump 100-250 OH2 | DN100, 250mm impeller, very large flow medium pressure | 120–220 m³/h / 70–110 m | 160 kW | Cross‑country pipeline booster, crude oil main line |
| Booster Pump 100-315 OH2 | DN100, 315mm impeller, very large flow high pressure | 120–220 m³/h / 110–160 m | 160 kW | Petrochemical complex pressurization, refinery main booster |
| Booster Pump 100-400 OH2 | DN100, 400mm impeller, very large flow ultra‑high head | 110–210 m³/h / 180–240 m | 315 kW | Ultra‑high pressure injection, mountain pipeline booster |
| Booster Pump 125-250 OH2 | DN125, 250mm impeller, giant flow | 200–350 m³/h / 80–120 m | 200 kW | Large tank farm export, national pipeline network booster |
| Booster Pump 125-315 OH2 | DN125, 315mm impeller, giant flow high pressure | 200–350 m³/h / 110–160 m | 315 kW | Mega‑refinery main booster, cross‑border pipeline |
| Booster Pump 150-315 OH2 | DN150, 315mm impeller, extra‑large flow | 300–550 m³/h / 90–140 m | 450 kW | World‑scale pipeline booster, power plant circulating water pressurization |
| Booster Pump 150-400 OH2 | DN150, 400mm impeller, top large flow high pressure | 300–550 m³/h / 160–220 m | 630 kW | Ultra‑large oil/gas pipeline, high‑pressure injection station |
6. Selection Notes (Booster‑Specific – Critical)
Differential pressure priority: Select based on maximum differential pressure. Add 10–20% capacity margin to avoid overload.
Cavitation control: Must have NPSHa ≥ NPSHr + 2.5 m (≥3.0 m for low inlet pressure). Add inducer or booster tank if needed.
Material selection: Carbon steel for neutral media; 316L/duplex for chlorides/corrosive service; chrome‑moly for high temperature (>200°C).
Seal matching: For discharge pressure ≥5 MPa, double seals + Plan 53A are mandatory. Flammable/explosive media require explosion‑proof motor and static grounding.
Operating range: Keep operating point within high‑efficiency zone (design flow ±15%) to avoid low‑flow overheating and high‑flow cavitation.
7. Contact Us
For detailed technical datasheets, model selection assistance (free selection report with inlet/outlet pressures, flow, media properties, temperature), 3D models (STEP/IGES), certification documents (API 610, ATEX/IECEx, NACE MR0175), and customized solutions (high‑differential pressure, high‑temperature, low‑NPSH inducer), please contact:
Email: info@hyrig.com
Our engineering team responds within 24 hours with API 610 compliant solutions tailored to your pressure boosting and high‑head transfer needs.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.