1. Product Overview
The OH2 Series Reflux Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 12th Edition (ISO 13709) international standards. It is purpose-built for demanding applications such as petrochemical distillation columns, fine chemical separation units, pharmaceutical purification systems, and food distillation processes. The primary function is to steadily return distillate from the top of the distillation column back into the column, maintaining vapor‑liquid equilibrium and separation efficiency. Media characteristics include viscosity 0.5–50 mPa·s (at 20°C), high volatility (normal boiling point 40–180°C), high purity (≥99.5%), operating temperature range -10°C to 160°C, and possible flammability or corrosivity. This pump achieves long‑term continuous operation (annual operation rate ≥99.8%) and is a critical equipment for distillation systems, directly affecting product purity and process stability.
Model Code Interpretation (OH2):
O = Overhung: Impeller outside bearing housing – compact structure, facilitates low‑pulsation and high‑purity sealing.
H = Horizontal: Horizontal mounting, compatible with reflux system layouts.
2 = 2nd Generation: Centerline support design – superior thermal stability for temperature fluctuations (40–120°C).
Key API 610 Compliance Features:
Centerline mounting per API 610 9.1.1.1 – no rear bracket, free axial expansion.
Back pull-out design (DBSE per API 610 9.1.1.2) – rotor removal without disconnecting piping or motor.
Distillation‑specific optimization – low‑pulsation, low‑shear flow path and high‑purity material system.
2. Key Structural Features (Reflux‑Specific Design)
2.1 Steady‑Flow Low‑Pulsation Flow Path System
Low specific speed precision impeller (n_s = 100–180), constant‑section slow‑flow profile. CFD‑optimized, surface roughness Ra ≤0.4 μm (electropolished) – flow pulsation ≤±1% at design point (vs. ±5% for conventional pumps).
Inlet stabilization guide section, diffuser‑type outlet with pressure stabilization chamber – reduces vaporization and pulsation caused by velocity changes, ensuring stable reflux ratio control accuracy of ±0.5%.
SFI ≤0.3 per API 610 Appendix K, rigid shaft with G1.0 dynamic balance – vibration velocity ≤2.5 mm/s, avoiding pulsation interference with column mass transfer.
2.2 High‑Purity Corrosion‑Resistant Material System
Base material module: Wetted parts standard 316L stainless steel (Mo ≥2.2%), electropolished (Ra ≤0.4 μm) for most neutral high‑purity reflux liquids (e.g., ethanol, toluene, aromatics) – no media contamination, uniform corrosion rate ≤0.01 mm/year.
High‑corrosion module: For acidic/alkaline reflux (e.g., acetic acid, ammonia), use 2205 duplex steel (PREN ≥34) or Hastelloy C‑276 – NACE MR0175 compliant, Cl⁻ tolerance up to 200,000 ppm.
Specialty module: For food/pharma grade reflux (e.g., pharmaceutical ethanol, purified solvents), use 316L ultra‑clean material – FDA certified, dead‑free design. For high‑temperature reflux (>120°C), use chrome‑moly steel; for low‑temperature reflux (<-10°C), use A352 LCB.
Auxiliary components: Shaft material 17-4PH or Hastelloy, shaft sleeve silicon carbide ceramic, gaskets PTFE or spiral wound (silicone rubber for food grade) – no material contamination or corrosion wear.
2.3 Low‑Cavitation Leak‑Tight Sealing System
Standard API 682 Type 22 double mechanical seals. Friction pairs: silicon carbide + graphite (high‑purity grade). Seal chamber with FFKM O‑rings – reflux swell ≤3%. Leakage ≤1 ppm, meeting zero‑contamination requirements for high‑purity media.
Modular flush plans: Normal service – Plan 53A (pressurized high‑purity solvent flush) to prevent air and impurities ingress. High‑temperature / volatile service – Plan 54 (forced cooling flush) to keep seal chamber ≤60°C. High‑purity service – Plan 11 with filtration to avoid external contamination.
Explosion safety reinforcement: For flammable reflux (e.g., methanol, acetone), full metal bonding and grounding (static resistance ≤10Ω), motor meets Ex d IIB T4 with ATEX/IECEx certification.
2.4 Centerline Mounting Thermal Stability Structure
Precision cast + CNC machined one‑piece casing. Shaft runout ≤0.02 mm from -10°C to 160°C, fully compliant with API 610 thermal distortion control.
Bearing housing with independent cooling chamber (water or air cooled) – oil temperature ≤75°C. Heavy‑duty bearings with oil mist lubrication – bearing life ≥30,000 hours.
Casing with optional steam/electric tracing jacket for crystallizing reflux (e.g., certain esters, aromatics) to prevent flow path blockage.
3. General Technical Specifications (Reflux‑Specific Parameters)
| Parameter | Value |
|---|---|
| Capacity | 5 – 2,800 m³/h (customizable to 3,000 m³/h) – supports precision small flow reflux (5–50 m³/h) and large column reflux (500–2,800 m³/h) |
| Head | 20 – 300 m (max. 984 ft) – stable output at 0.5–50 mPa·s; high‑head for tall columns (≥50 m) |
| Operating Temperature | -10°C to 160°C (common 40–120°C); high‑temp to 180°C (chrome‑moly); low‑temp to -30°C (cryogenic alloy) |
| Inlet Pressure | -0.03 to 0.3 MPa; Outlet Pressure: 0.2–12 MPa (standard 6 MPa, max 12 MPa) |
| Media Characteristics | Viscosity 0.5–50 mPa·s (20°C), purity ≥99.5%, flash point -40–60°C (some media), pH 2–12, solids ≤0.1 mm |
| Motor Power | 2.2 – 630 kW, efficiency ≥91% – power margin ≥15% for high‑viscosity service |
| Speed | 50Hz: 1,450/2,900 rpm; 60Hz: 1,750/3,500 rpm |
| Flange Rating | Class 150/300/600# (RF, ASME B16.5) |
| Material Options | 316L (standard), 2205 duplex (high corrosion), Hastelloy C‑276 (extreme), chrome‑moly (high temp), low‑temp steel |
| Standards | API 610 12th, API 682, NACE MR0175/ISO 15156, GB/T 3215, FDA (food/pharma grade) |
4. Global Equivalent Models (API 610 OH2 for Reflux)
| Brand | Series / Models | Key Adaptation |
|---|---|---|
| Sulzer | OHH 65-200, 100-315 | Distillation reflux dedicated, flow pulsation ≤±1%, 316L electropolished, aromatic systems |
| Flowserve | HPX 350, 450 | Petrochemical reflux adapted, Plan 53A flush, Ex d IIB T4, life ≥18,000 h |
| KSB | KZE 80-250, 125-315 | Fine chemical reflux, acid/alkali resistant, NPSHr ≤2.0 m, low‑level reflux drum transfer |
| Nikkiso | CZ-R series | Leak‑free magnetic drive (API 685) for high‑purity / toxic reflux |
| Xylem | Flygt R series | Large column reflux, steady‑flow design, efficiency ≥86%, million‑ton refining |
5. Complete OH2 Reflux Pump Model Lineup (20 Core Models by Size)
Small Bore (DN40/DN50 – Small Distillation Columns / Lab)
Reflux Pump 40-250 OH2 – API 610 OH2, DN40, 250mm impeller, high pressure small flow. Capacity/Head: 25–50 m³/h / 80–110 m. Power: 18.5 kW. Application: Small distillation column reflux, lab purification system.
Reflux Pump 40-315 OH2 – DN40, 315mm impeller, ultra‑high head. Capacity/Head: 20–45 m³/h / 120–160 m. Power: 22 kW. Application: High‑pressure distillation reflux, small specialty solvent reflux booster.
Reflux Pump 50-160 OH2 – DN50, 160mm impeller, general small flow. Capacity/Head: 30–60 m³/h / 35–50 m. Power: 11 kW. Application: Pharmaceutical purification reflux, small food distillation reflux.
Reflux Pump 50-200 OH2 – DN50, 200mm impeller, standard. Capacity/Head: 30–65 m³/h / 50–70 m. Power: 15 kW. Application: Fine chemical distillation reflux, small aromatic separation reflux.
Reflux Pump 50-250 OH2 – DN50, 250mm impeller, high pressure. Capacity/Head: 30–65 m³/h / 80–115 m. Power: 22 kW. Application: High‑head distillation column reflux, small long‑distance reflux pipeline.
Medium Bore (DN65/DN80 – Medium Distillation Columns / Plant Centralized)
Reflux Pump 65-160 OH2 – DN65, 160mm impeller, medium flow low pressure. Capacity/Head: 50–100 m³/h / 32–48 m. Power: 18.5 kW. Application: Medium distillation column reflux, workshop solvent distillation main pump.
Reflux Pump 65-200 OH2 – DN65, 200mm impeller, medium flow general. Capacity/Head: 50–110 m³/h / 48–72 m. Power: 30 kW. Application: Petrochemical aromatic distillation reflux, medium pharmaceutical purification reflux.
Reflux Pump 65-250 OH2 – DN65, 250mm impeller, medium flow high pressure. Capacity/Head: 50–110 m³/h / 75–110 m. Power: 45 kW. Application: High‑tower distillation reflux, medium solvent distillation reflux booster.
Reflux Pump 65-315 OH2 – DN65, 315mm impeller, medium flow ultra‑high head. Capacity/Head: 45–100 m³/h / 120–160 m. Power: 75 kW. Application: Ultra‑high pressure distillation reflux, mountainous plant column reflux pump.
Reflux Pump 80-160 OH2 – DN80, 160mm impeller, large flow low pressure. Capacity/Head: 80–160 m³/h / 30–48 m. Power: 37 kW. Application: Large distillation column pre‑reflux, workshop central distillation reflux.
Reflux Pump 80-200 OH2 – DN80, 200mm impeller, main duty. Capacity/Head: 80–160 m³/h / 48–72 m. Power: 55 kW. Application: Large paint solvent distillation reflux, medium distillation system main pump.
Reflux Pump 80-250 OH2 – DN80, 250mm impeller, large flow medium‑high pressure. Capacity/Head: 80–160 m³/h / 75–115 m. Power: 90 kW. Application: Long‑distance reflux pipeline, large distillation column main reflux pump.
Reflux Pump 80-315 OH2 – DN80, 315mm impeller, large flow high pressure. Capacity/Head: 75–150 m³/h / 120–165 m. Power: 132 kW. Application: Ultra‑high pressure distillation system reflux, large petrochemical distillation terminal.
Large Bore (DN100/DN125/DN150 – Large Distillation Columns / Plant‑Wide)
Reflux Pump 100-200 OH2 – DN100, 200mm impeller, very large flow. Capacity/Head: 120–220 m³/h / 45–70 m. Power: 75 kW. Application: Extra‑large distillation column reflux, plant‑wide central distillation reflux.
Reflux Pump 100-250 OH2 – DN100, 250mm impeller, very large flow medium pressure. Capacity/Head: 120–220 m³/h / 70–110 m. Power: 160 kW. Application: Cross‑border petrochemical base distillation reflux, large refining distillation main pump.
Reflux Pump 100-315 OH2 – DN100, 315mm impeller, very large flow high pressure. Capacity/Head: 120–220 m³/h / 115–160 m. Power: 250 kW. Application: Ultra‑large distillation system reflux, million‑ton aromatic separation pump.
Reflux Pump 100-400 OH2 – DN100, 400mm impeller, very large flow ultra‑high head. Capacity/Head: 110–210 m³/h / 180–240 m. Power: 400 kW. Application: Long‑distance high‑pressure reflux network, world‑class distillation column main pump.
Reflux Pump 125-250 OH2 – DN125, 250mm impeller, giant flow. Capacity/Head: 200–350 m³/h / 65–100 m. Power: 200 kW. Application: National chemical park distillation reflux, large pharmaceutical base main pump.
Reflux Pump 125-315 OH2 – DN125, 315mm impeller, giant flow high pressure. Capacity/Head: 200–350 m³/h / 110–155 m. Power: 315 kW. Application: Ultra‑large petrochemical distillation terminal, cross‑border chemical enterprise reflux pump.
Reflux Pump 150-315 OH2 – DN150, 315mm impeller, extra‑large flow. Capacity/Head: 300–550 m³/h / 90–140 m. Power: 450 kW. Application: Global large distillation recovery hub, ultra‑large aromatic separation pump.
Reflux Pump 150-400 OH2 – DN150, 400mm impeller, top large flow high pressure. Capacity/Head: 300–550 m³/h / 160–220 m. Power: 630 kW. Application: World‑class chemical base distillation reflux project, global top refining reflux pump.
6. Selection Notes (Reflux‑Specific – Critical)
Precise reflux ratio matching: Determine pump flow based on column design reflux ratio (typically 1–5). Select at 1.2 × maximum reflux flow, with flow turndown covering 30–110% of design flow. Equip with VFD for stepless reflux ratio adjustment.
Cavitation control: High volatility reflux requires NPSHa ≥ NPSHr + 2.5 m (≥3.0 m for high temperature). Raise reflux drum level, lower pump installation height, increase suction pipe diameter, or add inducer.
Purity & contamination control: For high‑purity media (≥99.9%), must use 316L electropolished materials + zero‑leakage seals. Provide FDA certification and cleaning validation reports for food/pharma grade.
Material compatibility: Neutral reflux → 316L (most economical); acidic reflux (pH ≤4) → 2205 duplex; strong oxidizing reflux (e.g., nitric acid) → Hastelloy C‑276. Flammable reflux requires explosion protection.
Operational stability: Keep operating point within high‑efficiency zone (design flow ±15%) to avoid low‑flow overheating and vaporization. Minimize throttling, use VFD to reduce pulsation and energy consumption, ensuring column vapor‑liquid balance.
7. Contact Us
For detailed technical datasheets, model selection assistance (free selection report with reflux ratio, media type, temperature, pressure, flow/head), 3D models (STEP/IGES), certification documents (API 610, ATEX/IECEx, material purity reports, FDA), and customized solutions (high‑purity reflux, high‑temp high‑pressure distillation, corrosive reflux), please contact:
Email: info@hyrig.com
Our engineering team responds within 24 hours with API 610 compliant solutions tailored to your distillation reflux and high‑purity transfer needs.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.