1. Product Overview
The OH2 Series Condensate Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 12th Edition (ISO 13709) international standards. It is specifically engineered for handling high-temperature condensate water (steam system condensate) in demanding applications such as thermal power plants, petrochemical refining, coal chemical plants, and industrial steam systems. Condensate characteristics include high temperature (80–150°C, near boiling), low inlet pressure (-0.02 to 0.2 MPa, vacuum to slight positive pressure), trace steam content (prone to flashing), low viscosity (≈0.55 mPa·s at 20°C), and mild corrosivity (pH 7–9). This pump achieves long-term continuous operation (annual operation rate ≥99.8%) and is a critical equipment for condensate recovery and transfer.
Model Code Interpretation (OH2):
O = Overhung: Impeller outside bearing housing – compact structure, facilitates low NPSH and high‑temperature sealing.
H = Horizontal: Horizontal mounting, compatible with condensate system layouts.
2 = 2nd Generation: Centerline support design – superior thermal stability for temperature fluctuations (80–150°C).
Key API 610 Compliance Features:
Centerline mounting per API 610 9.1.1.1 – no rear bracket, free axial expansion.
Back pull-out design (DBSE per API 610 9.1.1.2) – rotor removal without disconnecting piping or motor, maintenance time reduced by 60%.
Ultra‑low NPSH hydraulic design – specifically optimized for high‑temperature saturated water to eliminate cavitation.
2. Key Structural Features (Condensate‑Specific Design)
2.1 Ultra‑Low NPSH Hydraulic Design (Core Feature)
Double‑suction inducer + closed impeller – NPSHr ≤ 1.0 m (conventional pumps ≥2.5 m), completely solving high‑temperature condensate cavitation.
Specific speed n_s = 150–220 for high‑temperature, low‑viscosity, high‑velocity service.
Double volute design balances radial forces – vibration velocity ≤1.8 mm/s (40% lower than conventional pumps).
Flow path polished to Ra ≤0.4 μm to reduce steam adhesion and flashing.
2.2 Materials (High‑Temperature, Erosion‑Resistant, Corrosion‑Resistant)
Casing/impeller: Carbon steel (A216 WCB) standard; for high‑temperature / high‑pressure, use 304/316L stainless steel.
Shaft: 420 stainless steel or 17-4PH – high‑temperature resistant, corrosion resistant.
Seal rings / shaft sleeve: Silicon carbide (SiC) – wear‑resistant, cavitation‑erosion resistant.
Thermal expansion compensation: Centerline mounting, shaft runout ≤0.02 mm from -40°C to 180°C.
2.3 Sealing System (API 682 + Cavitation Protection)
Standard: API 682 Type 21 single mechanical seal (clean condensate).
For high‑temperature / flashing service: Type 22 double seals + Plan 52 (atmospheric isolation fluid to prevent steam ingress).
Friction pairs: SiC vs carbon graphite (thermally conductive, dry‑run resistant, anti‑static).
O‑rings: FKM – resistant to 180°C, hydrolysis resistant.
Leakage control: ≤5 ppm, meeting power plant zero‑leakage requirements.
2.4 Back Pull‑Out + Heavy‑Duty Bearing Housing (Thermal Stability + Easy Maintenance)
Back pull‑out design allows rotor removal without disconnecting piping or motor – maintenance time reduced by 60%.
Centerline support maintains pump‑motor alignment at high temperatures – stable shaft vibration.
Bearing housing with independent cooling chamber (water or air cooled) – oil temperature ≤70°C. Oil mist lubrication – bearing life ≥40,000 hours.
Automatic air vent at top of casing prevents vapor accumulation and air binding.
3. General Technical Specifications (Condensate‑Specific Parameters)
| Parameter | Typical Range |
|---|---|
| Capacity | 10 – 2,000 m³/h (customizable to 2,500 m³/h) – supports small recovery (10–50 m³/h) and large power plant circulation (500–2,000 m³/h) |
| Head | 20 – 250 m (max. 820 ft) |
| Operating Temperature | 80 – 150°C (saturated temperature) |
| Inlet Pressure | -0.02 to 0.2 MPa (vacuum to slight positive pressure) |
| Outlet Pressure | 0.3 – 8.0 MPa |
| Media Characteristics | Clean condensate, pH 7–9, trace iron ions, low viscosity (~0.55 mPa·s at 20°C) |
| Motor Power | 5.5 – 500 kW, efficiency ≥91% |
| Speed | 50Hz: 1,450/2,900 rpm; 60Hz: 1,750/3,500 rpm (low speed for high‑temp service) |
| Flange Rating | Class 150/300/600# (RF, ASME B16.5) |
| Material Options | Carbon steel (WCB), 304/316L stainless steel, duplex steel |
| NPSHr | ≤1.0 m (with inducer) |
| Standards | API 610 12th, API 682, GB/T 3215, ASME B73.1 |
4. Global Equivalent Models (API 610 OH2 for Condensate)
| Brand | Series / Models | Key Adaptation |
|---|---|---|
| Sulzer | OHH 65-200, 100-315 | Low NPSH inducer design, carbon steel standard, power plant condensate |
| Flowserve | HPX 250, 350 | Petrochemical condensate recovery, Plan 52 seals, life ≥20,000 h |
| KSB | KZE 80-200, 100-250 | Coal chemical condensate, NPSHr ≤1.2 m, high‑temp bearing cooling |
| Grundfos | NK/CR series | Small condensate units – vertical compact, automatic air vent |
| Ebara | CWA series | Power plant condensate booster, double volute, low vibration |
5. Complete OH2 Condensate Pump Model Lineup (20 Core Models by Size)
Small Bore (DN40/DN50 – Small Condensate Systems / Boiler Feed Pre‑Stage)
Condensate Pump 40-250 OH2 – API 610 OH2, DN40, 250mm impeller, high pressure small flow. Capacity/Head: 25–50 m³/h / 80–110 m. Power: 18.5 kW. Application: Small boiler condensate recovery, process heating return.
Condensate Pump 50-160 OH2 – DN50, 160mm impeller, general small flow. Capacity/Head: 30–60 m³/h / 35–50 m. Power: 11 kW. Application: Laboratory steam system, small industrial condensate transfer.
Condensate Pump 50-200 OH2 – DN50, 200mm impeller, standard. Capacity/Head: 30–65 m³/h / 50–70 m. Power: 15 kW. Application: Boiler feed pre‑stage, low‑pressure steam line drainage.
Condensate Pump 50-250 OH2 – DN50, 250mm impeller, high pressure. Capacity/Head: 30–65 m³/h / 80–115 m. Power: 22 kW. Application: High‑head condensate return, long‑distance transfer from steam traps.
Condensate Pump 65-160 OH2 – DN65, 160mm impeller, medium flow low pressure. Capacity/Head: 50–100 m³/h / 32–48 m. Power: 18.5 kW. Application: Medium plant condensate collection, heating system return.
Medium Bore (DN65/DN80 – Mainstream Condensate Service)
Condensate Pump 65-200 OH2 – DN65, 200mm impeller, medium flow general. Capacity/Head: 50–110 m³/h / 48–72 m. Power: 30 kW. Application: Power plant condensate main pump, refinery steam system recovery.
Condensate Pump 65-250 OH2 – DN65, 250mm impeller, medium flow high pressure. Capacity/Head: 50–110 m³/h / 80–110 m. Power: 37 kW. Application: Steam network condensate transfer, high‑pressure boiler feed pre‑stage.
Condensate Pump 65-315 OH2 – DN65, 315mm impeller, medium flow ultra‑high head. Capacity/Head: 45–100 m³/h / 120–160 m. Power: 75 kW. Application: High‑rise building condensate lift, mountainous plant condensate booster.
Condensate Pump 80-160 OH2 – DN80, 160mm impeller, large flow low pressure. Capacity/Head: 80–160 m³/h / 30–48 m. Power: 37 kW. Application: Large steam system circulation, district heating condensate return.
Condensate Pump 80-200 OH2 – DN80, 200mm impeller, main duty. Capacity/Head: 80–160 m³/h / 48–72 m. Power: 55 kW. Application: Power plant condensate extraction, coal chemical steam recovery main pump.
Condensate Pump 80-250 OH2 – DN80, 250mm impeller, large flow medium‑high pressure. Capacity/Head: 80–160 m³/h / 75–115 m. Power: 90 kW. Application: Long‑distance condensate pipeline, large refinery condensate main pump.
Condensate Pump 80-315 OH2 – DN80, 315mm impeller, large flow high pressure. Capacity/Head: 75–150 m³/h / 120–165 m. Power: 132 kW. Application: High‑pressure condensate system, supercritical power plant booster.
Large Bore (DN100/DN125/DN150 – Large Condensate Systems / Plant‑Wide)
Condensate Pump 100-200 OH2 – DN100, 200mm impeller, very large flow. Capacity/Head: 120–220 m³/h / 45–70 m. Power: 75 kW. Application: Extra‑large power plant condensate extraction, central heating return main pump.
Condensate Pump 100-250 OH2 – DN100, 250mm impeller, very large flow medium pressure. Capacity/Head: 120–220 m³/h / 70–110 m. Power: 160 kW. Application: Petrochemical steam system condensate recovery, large coal chemical plant.
Condensate Pump 100-315 OH2 – DN100, 315mm impeller, very large flow high pressure. Capacity/Head: 120–220 m³/h / 115–160 m. Power: 250 kW. Application: Ultra‑high pressure condensate system, million‑ton refining unit.
Condensate Pump 125-250 OH2 – DN125, 250mm impeller, giant flow. Capacity/Head: 200–350 m³/h / 65–100 m. Power: 200 kW. Application: National power grid condensate recovery, large petrochemical base main pump.
Condensate Pump 125-315 OH2 – DN125, 315mm impeller, giant flow high pressure. Capacity/Head: 200–350 m³/h / 110–155 m. Power: 315 kW. Application: Ultra‑large power plant, cross‑border industrial steam system condensate pump.
Condensate Pump 150-315 OH2 – DN150, 315mm impeller, extra‑large flow. Capacity/Head: 300–550 m³/h / 90–140 m. Power: 450 kW. Application: Global large power station condensate extraction, super‑large coal chemical plant.
Condensate Pump 150-400 OH2 – DN150, 400mm impeller, top large flow high pressure. Capacity/Head: 300–550 m³/h / 160–220 m. Power: 630 kW. Application: World‑class power generation facility, ultra‑high pressure condensate main pump.
6. Selection Notes (Condensate‑Specific – Critical)
NPSH (Cavitation margin): Must have NPSHa ≥ NPSHr + 2.0 m (≥3.0 m for high‑temperature saturated water). Prefer inducer design. Add condensate tank or lower installation height if needed.
Temperature adaptation: For media temperature ≥120°C, double seals + Plan 52 are mandatory. Bearing housing must have independent cooling.
Material selection: Carbon steel for clean condensate; 316L for trace chloride (>50 ppm); silicon carbide seal rings for steam erosion protection.
Operating range: Keep operating point within high‑efficiency zone (design flow ±15%) to avoid low‑flow overheating/flashing and high‑flow cavitation.
Air vent & insulation: Automatic air vent on casing must be kept open. Suction piping fully insulated to prevent heat loss and flashing.
7. Contact Us
For detailed technical datasheets, model selection assistance (free selection report with condensate temperature, inlet pressure, flow/head), 3D models (STEP/IGES), certification documents (API 610, material test reports), and customized solutions (high‑temp inducer design, low‑NPSH special, automatic venting system), please contact:
Email: info@hyrig.com
Our engineering team responds within 24 hours with API 610 compliant solutions tailored to your condensate recovery and high‑temperature water transfer needs.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.