1. Product Overview
The OH2 Series Solvent Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 12th Edition (ISO 13709) international standards. It is purpose-built for demanding applications such as fine chemical synthesis, pharmaceutical manufacturing, paint production, petrochemical aromatic extraction, and electronic chemical manufacturing. This pump is specifically engineered to handle various industrial solvents (including aromatics, ketones, esters, alcohol ethers, halogenated hydrocarbons, and specialty solvents). Media characteristics include viscosity 0.3–100 mPa·s (at 20°C), high volatility (normal boiling point 30–180°C), flammability (flash point -40–60°C), wide corrosion range (pH 1–13), and possible trace impurities. It achieves long‑term continuous operation (annual operation rate ≥99.7%) and is a critical equipment for solvent synthesis, distillation, recovery, and circulation systems.
Model Code Interpretation (OH2):
O = Overhung: Impeller outside bearing housing – compact structure, facilitates multi‑solvent sealing.
H = Horizontal: Horizontal mounting, compatible with solvent system layouts.
2 = 2nd Generation: Centerline support design – superior thermal stability for temperature fluctuations (-20°C to 150°C).
Key API 610 Compliance Features:
Centerline mounting per API 610 9.1.1.1 – no rear bracket, free axial expansion.
Back pull-out design (DBSE per API 610 9.1.1.2) – rotor removal without disconnecting piping or motor.
Multi‑solvent optimized design – modular flow path and material system for low‑viscosity cavitation prevention, high‑viscosity low resistance, and corrosive resistance.
2. Key Structural Features (Solvent‑Specific Design)
2.1 Low‑Shear Vaporization‑Resistant Flow Path System
Variable specific speed impeller (n_s = 100–200) for wide viscosity range (0.3–100 mPa·s): For low‑viscosity solvents (≤5 mPa·s), high‑flow hydraulic design with NPSHr ≤2.5 m; for high‑viscosity solvents (≥50 mPa·s), wide‑channel low‑shear profile with flow path width ≥20 mm, reducing turbulence and vaporization risk.
CFD‑optimized flow path, surface roughness Ra ≤0.8 μm. Inlet stabilization diffuser section and slow‑expansion outlet reduce velocity‑induced vaporization – vaporization suppression rate 45% higher than conventional pumps.
SFI ≤0.3 per API 610 Appendix K, rigid shaft design ensures stable operation across wide viscosity range – vibration velocity ≤2.8 mm/s, meeting low‑vibration requirements for hazardous areas.
2.2 Multi‑Solvent Corrosion Resistant Material System
Base material module: Wetted parts standard 316L stainless steel (Mo ≥2.2%) for most neutral/mildly corrosive solvents (e.g., ethanol, acetone, toluene) – uniform corrosion rate ≤0.01 mm/year.
High‑corrosion module: For halogenated hydrocarbons and acid/alkaline solvents, use 2205 duplex steel (PREN ≥34) or Hastelloy C‑276 – compliant with NACE MR0175/ISO 15156, Cl⁻ tolerance up to 200,000 ppm.
Specialty module: For food/pharma grade solvents (e.g., pharmaceutical ethanol, purified solvents), use 316L electropolished (Ra ≤0.4 μm) – FDA compliant. For high‑temperature solvents (>120°C), use chrome‑moly steel; for low‑temperature solvents (<-20°C), use A352 LCB.
Auxiliary components: Shaft material 17-4PH or Hastelloy, shaft sleeve silicon carbide ceramic – eliminates solvent corrosion and wear.
2.3 Explosion‑Proof & Leak‑Tight Sealing System
Standard API 682 Type 22 double mechanical seals. Friction pairs: silicon carbide + graphite (anti‑static). Seal chamber with FFKM O‑rings – solvent swell ≤3%. Leakage ≤1 ppm, meeting zero‑leakage requirements for hazardous areas.
Modular flush plans: Normal service – Plan 53A (pressurized nitrogen‑blanketed isolation fluid) to prevent solvent‑air contact. High‑temperature / volatile service – Plan 54 (forced cooling flush) to keep seal chamber ≤60°C. Trace‑impurity service – Plan 21 (external clean solvent flush).
Explosion safety reinforcement: Full metal bonding and grounding – static discharge resistance ≤10Ω to prevent spark ignition of solvent vapors. Motor meets Ex d IIB T4 (Zone 1/2) with ATEX/IECEx certification.
2.4 Centerline Mounting Thermal Stability Structure
Precision cast one‑piece casing. Shaft runout ≤0.02 mm from -40°C to 180°C, fully compliant with API 610 thermal distortion control.
Bearing housing with independent cooling chamber (water or air cooled) – oil temperature ≤80°C. Heavy‑duty bearings with oil mist lubrication – bearing life ≥30,000 hours.
Casing with optional steam/electric tracing jacket for crystallizing solvents (e.g., certain esters) to prevent flow path blockage.
3. General Technical Specifications (Solvent‑Specific Parameters)
| Parameter | Value |
|---|---|
| Capacity | 5 – 3,000 m³/h (customizable to 3,500 m³/h) – supports small solvent circulation (5–50 m³/h) and large recovery systems (500–3,000 m³/h) |
| Head | 15 – 350 m (max. 1,148 ft) – stable output at 0.3–100 mPa·s; high‑head for high‑pressure distillation feed |
| Operating Temperature | -40°C to 180°C (common -10–120°C); high‑temp to 200°C (chrome‑moly); low‑temp to -60°C (cryogenic alloy) |
| Inlet Pressure | -0.05 to 0.3 MPa; Outlet Pressure: 0.15–15 MPa (standard 8 MPa, max 15 MPa) |
| Media Characteristics | Viscosity 0.3–100 mPa·s (20°C), flash point -40–60°C, explosion limit 1.5–40% (vol), pH 1–13, trace solids ≤0.5 mm |
| Motor Power | 2.2 – 630 kW, efficiency ≥90% – power margin ≥20% for high‑viscosity / solids‑laden service |
| Speed | 50Hz: 1,450/2,900 rpm; 60Hz: 1,750/3,500 rpm |
| Flange Rating | Class 150/300/600# (RF, ASME B16.5) |
| Material Options | 316L (standard), 2205 duplex (high corrosion), Hastelloy C‑276 (extreme), chrome‑moly (high temp), low‑temp steel |
| Standards | API 610 12th, API 682, NACE MR0175/ISO 15156, GB/T 3215, ATEX/IECEx |
4. Global Equivalent Models (API 610 OH2 for Solvent)
| Brand | Series / Models | Key Adaptation |
|---|---|---|
| Sulzer | OHH 65-200, 100-315 | Multi‑solvent modular materials, efficiency ≥85%, aromatic extraction and solvent recovery |
| Flowserve | HPX 400, 500 | Petrochemical solvent dedicated, Plan 53A flush, Ex d IIB T4, life ≥15,000 h |
| KSB | KZE 80-250, 125-315 | Fine chemical, acid/alkali resistant, NPSHr ≤2.8 m, low‑level tank transfer |
| Nikkiso | CZ-S series | Leak‑free magnetic drive (API 685) for toxic solvents |
| Grundfos | DMX series | Small solvent circulation – vertical compact, explosion‑proof, noise ≤75 dB(A) |
5. Complete OH2 Solvent Pump Model Lineup (20 Core Models by Size)
Small Bore (DN40/DN50 – Small Systems / Lab)
Solvent Pump 40-250 OH2 – API 610 OH2, DN40, 250mm impeller, high pressure small flow. Capacity/Head: 25–50 m³/h / 80–110 m. Power: 18.5 kW. Application: Lab solvent distillation, small pharmaceutical synthesis feed.
Solvent Pump 40-315 OH2 – DN40, 315mm impeller, ultra‑high head. Capacity/Head: 20–45 m³/h / 120–160 m. Power: 22 kW. Application: High‑pressure solvent injection, small specialty solvent recovery booster.
Solvent Pump 50-160 OH2 – DN50, 160mm impeller, general small flow. Capacity/Head: 30–60 m³/h / 35–50 m. Power: 11 kW. Application: Electronic chemical solvent transfer, small paint blending circulation.
Solvent Pump 50-200 OH2 – DN50, 200mm impeller, standard. Capacity/Head: 30–65 m³/h / 50–70 m. Power: 15 kW. Application: Fine chemical solvent circulation, small aromatic extraction.
Solvent Pump 50-250 OH2 – DN50, 250mm impeller, high pressure. Capacity/Head: 30–65 m³/h / 80–115 m. Power: 22 kW. Application: High‑viscosity solvent boosting, small long‑distance solvent transfer.
Medium Bore (DN65/DN80 – Medium Systems / Plant Centralized)
Solvent Pump 65-160 OH2 – DN65, 160mm impeller, medium flow low pressure. Capacity/Head: 50–100 m³/h / 32–48 m. Power: 18.5 kW. Application: Medium solvent recovery, workshop solvent circulation main pump.
Solvent Pump 65-200 OH2 – DN65, 200mm impeller, medium flow general. Capacity/Head: 50–110 m³/h / 48–72 m. Power: 30 kW. Application: Petrochemical aromatic extraction, medium pharmaceutical synthesis feed.
Solvent Pump 65-250 OH2 – DN65, 250mm impeller, medium flow high pressure. Capacity/Head: 50–110 m³/h / 75–110 m. Power: 45 kW. Application: Long‑distance solvent pipeline, medium solvent distillation feed.
Solvent Pump 65-315 OH2 – DN65, 315mm impeller, medium flow ultra‑high head. Capacity/Head: 45–100 m³/h / 120–160 m. Power: 75 kW. Application: High‑pressure solvent atomization, mountainous workshop solvent booster.
Solvent Pump 80-160 OH2 – DN80, 160mm impeller, large flow low pressure. Capacity/Head: 80–160 m³/h / 30–48 m. Power: 37 kW. Application: Large solvent pretreatment, workshop central solvent circulation.
Solvent Pump 80-200 OH2 – DN80, 200mm impeller, main duty. Capacity/Head: 80–160 m³/h / 48–72 m. Power: 55 kW. Application: Large paint production solvent transfer, medium solvent recovery main pump.
Solvent Pump 80-250 OH2 – DN80, 250mm impeller, large flow medium‑high pressure. Capacity/Head: 80–160 m³/h / 75–115 m. Power: 90 kW. Application: Long‑distance solvent main pipeline, large solvent distillation feed.
Solvent Pump 80-315 OH2 – DN80, 315mm impeller, large flow high pressure. Capacity/Head: 75–150 m³/h / 120–165 m. Power: 132 kW. Application: Ultra‑high pressure solvent system, large petrochemical solvent terminal.
Large Bore (DN100/DN125/DN150 – Large Scale / Plant‑Wide)
Solvent Pump 100-200 OH2 – DN100, 200mm impeller, very large flow. Capacity/Head: 120–220 m³/h / 45–70 m. Power: 75 kW. Application: Extra‑large solvent recovery hub, plant‑wide solvent circulation.
Solvent Pump 100-250 OH2 – DN100, 250mm impeller, very large flow medium pressure. Capacity/Head: 120–220 m³/h / 70–110 m. Power: 160 kW. Application: Cross‑border petrochemical base solvent transfer, large refining solvent main pump.
Solvent Pump 100-315 OH2 – DN100, 315mm impeller, very large flow high pressure. Capacity/Head: 120–220 m³/h / 115–160 m. Power: 250 kW. Application: Ultra‑large solvent distillation system, million‑ton aromatic extraction pump.
Solvent Pump 100-400 OH2 – DN100, 400mm impeller, very large flow ultra‑high head. Capacity/Head: 110–210 m³/h / 180–240 m. Power: 400 kW. Application: Long‑distance high‑pressure solvent pipeline network, world‑class solvent processing main pump.
Solvent Pump 125-250 OH2 – DN125, 250mm impeller, giant flow. Capacity/Head: 200–350 m³/h / 65–100 m. Power: 200 kW. Application: National chemical park solvent circulation, large pharmaceutical base main pump.
Solvent Pump 125-315 OH2 – DN125, 315mm impeller, giant flow high pressure. Capacity/Head: 200–350 m³/h / 110–155 m. Power: 315 kW. Application: Ultra‑large petrochemical solvent terminal, cross‑border chemical enterprise pump.
Solvent Pump 150-315 OH2 – DN150, 315mm impeller, extra‑large flow. Capacity/Head: 300–550 m³/h / 90–140 m. Power: 450 kW. Application: Global large solvent recovery hub, ultra‑large aromatic extraction pump.
Solvent Pump 150-400 OH2 – DN150, 400mm impeller, top large flow high pressure. Capacity/Head: 300–550 m³/h / 160–220 m. Power: 630 kW. Application: World‑class chemical base solvent transfer project, global top refinery solvent pump.
6. Selection Notes (Solvent‑Specific)
Precise media matching: Identify solvent viscosity, flash point, boiling point, corrosivity (pH/Cl⁻ content), and explosion limits. Selection logic: viscosity → flow path, corrosivity → material, flammability → explosion protection rating.
Cavitation control: High volatility solvents require NPSHa ≥ NPSHr + 2.0 m (≥2.5 m for high temperature). Lower pump installation height, increase suction pipe diameter, add inducer or booster pump.
Explosion protection & seal compliance: Use Ex d IIB T4 or higher motor in hazardous areas. Prefer double mechanical seals + Plan 53A – single seals prohibited for flammable solvents. Full metal grounding required.
Material禁忌: Strong oxidizing solvents (e.g., nitric acid) – avoid standard stainless steel, use Hastelloy. Halogenated hydrocarbons – avoid conventional rubber seals, use FFKM.
Operating range: Keep operating point within high‑efficiency zone (design flow ±10%) to avoid low‑flow overheating and vaporization. Minimize throttling to reduce energy loss.
7. Contact Us
For detailed technical datasheets, model selection assistance (free selection report with solvent type, viscosity, temperature, pressure, flow/head), 3D models (STEP/IGES), certification documents (API 610, ATEX/IECEx, corrosion test reports), and customized solutions (high‑purity solvent, high‑temp high‑pressure, strong corrosive solvent), please contact:
Email: info@hyrig.com
Our engineering team responds within 24 hours with API 610 compliant solutions tailored to your solvent transfer and processing needs.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.