1. Product Overview
The OH2 Series Methanol Pump is a horizontal, single-stage, single-suction, overhung, centerline-mounted, radially split centrifugal pump, strictly designed and manufactured in accordance with API 610 12th Edition (ISO 13709) international standards. It is specifically engineered for handling methanol (CH₃OH) in demanding applications such as coal-to-methanol plants, methanol-to-olefins (MTO), formaldehyde/acetic acid synthesis, fuel blending, and fine chemical production. Methanol's challenging characteristics include low viscosity (≈0.55 mPa·s at 20°C), low boiling point (64.7°C at atmospheric pressure, causing high cavitation risk), strong permeability, flammability (flash point 11°C, explosion limit 6–36.5% by volume), moderate toxicity, and mild corrosivity (compatible with 304/316L). This pump achieves long-term continuous operation (annual operation rate ≥99.7%) and is a critical equipment for methanol feed, circulation, and transfer.
Model Code Interpretation (OH2):
O = Overhung: Impeller outside bearing housing – compact structure, facilitates low NPSH and explosion-proof sealing.
H = Horizontal: Horizontal mounting, compatible with methanol system layouts.
2 = 2nd Generation: Centerline support design – superior thermal stability for temperature fluctuations (-40°C to 180°C).
Key API 610 Compliance Features:
Centerline mounting per API 610 9.1.1.1 – no rear bracket, free axial expansion.
Back pull-out design (DBSE per API 610 9.1.1.2) – rotor removal without disconnecting piping or motor.
Low NPSH & anti-cavitation hydraulic design – specifically optimized for methanol's low viscosity and high vapor pressure.
2. Key Structural Features (Methanol-Specific Design)
Hydraulic Design – Low Cavitation, High Efficiency: Closed impeller with low NPSH design – NPSHr ≤ 2.0 m (preferred ≤1.5 m). Specific speed n_s = 120–200 for low-viscosity, high-velocity media. Double volute / balance holes to balance radial forces, reducing vibration and noise. Surface finish Ra ≤0.8 μm to minimize friction and static accumulation.
Material Selection – Explosion-Proof, Corrosion-Resistant, Anti-Static: Casing/impeller: 316L stainless steel (standard); 304 / duplex steel for high-pressure or low-temperature options. Shaft: 17-4PH or 316L stainless steel. Seal rings / shaft sleeve: silicon carbide (SiC) – wear-resistant, anti-static. Full metal conductivity with bonding/grounding to prevent static spark.
Sealing System – API 682 + Explosion-Proof: Standard: API 682 Type 22 double mechanical seals (prevents methanol leakage). Friction pairs: SiC vs carbon graphite (wear-resistant, thermally conductive, anti-static). O-rings: FKM or FFKM – methanol-resistant, low swell. Flush plans: Normal service – Plan 52 (atmospheric isolation fluid, leak detection); High-temperature / cavitation-prone – Plan 53A (pressurized isolation fluid). Leakage control: ≤1 ppm, compliant with Ex d IIB T4 hazardous area requirements.
Centerline Mounting + Back Pull-Out (Thermal Stability + Easy Maintenance): Centerline mounting compensates thermal expansion from -40°C to 180°C – shaft runout ≤0.02 mm. Back pull-out design allows rotor removal without disconnecting piping or motor – fast maintenance, short downtime. Heavy-duty bearing housing with oil mist lubrication and temperature monitoring – bearing life ≥30,000 hours.
3. General Technical Specifications (Methanol-Specific Parameters)
| Parameter | Typical Range |
|---|---|
| Capacity | 5 – 2,600 m³/h (customizable to 3,000 m³/h) |
| Head | 20 – 300 m (max. 984 ft) |
| Operating Temperature | -40°C to 180°C (common 25–80°C) |
| Inlet Pressure | -0.05 MPa to 0.3 MPa; Outlet Pressure: 0.2–10 MPa (standard 4 MPa, max 10 MPa) |
| Media Viscosity | 0.5 – 5 mPa·s |
| Material Options | 316L (standard), 304, duplex steel, Hastelloy |
| Explosion Protection | Ex d IIB T4 (Zone 1/2) |
| Speed | 50Hz: 1,450/2,900 rpm; 60Hz: 1,750/3,500 rpm |
| Flange Rating | Class 150/300/600# (RF, ASME B16.5) |
| Standards | API 610 12th, API 682, GB/T 3215, NACE MR0175 |
4. Global Equivalent Models (API 610 OH2 for Methanol)
| Brand | Series / Models | Key Adaptation |
|---|---|---|
| Sulzer | OHH 40-250, 65-315, 100-400 | Low NPSH design, 316L standard, anti-static seals |
| Flowserve | HPX 300, 400, 500 | MTO feed dedicated, Plan 53A flush, life ≥15,000 h |
| KSB | KZE 65-200, 100-315 | Coal-to-methanol circulation, NPSHr ≤1.8 m, Ex d IIB T4 |
| Amarinth | OH2 custom | High-purity methanol, low leakage (<1 ppm) |
5. Complete OH2 Methanol Pump Model Lineup (Core Models by Size)
Small Bore (DN40/DN50 – Small Flow, High Pressure Feed)
Methanol Pump 40-250 OH2 – API 610 OH2, DN40, 250mm impeller, high pressure small flow. Capacity/Head: 25–50 m³/h / 80–110 m. Power: 18.5 kW. Application: High-pressure methanol feed, small reactor feed.
Methanol Pump 50-160 OH2 – DN50, 160mm impeller, general small flow. Capacity/Head: 30–60 m³/h / 35–50 m. Power: 11 kW. Application: Small circulation, transfer, blending.
Medium Bore (DN65/DN80 – Mainstream Duty)
Methanol Pump 65-200 OH2 – DN65, 200mm impeller, medium flow general. Capacity/Head: 50–110 m³/h / 48–72 m. Power: 30 kW. Application: MTO unit circulation, methanol synthesis feed.
Methanol Pump 80-200 OH2 – DN80, 200mm impeller, main duty. Capacity/Head: 80–160 m³/h / 48–72 m. Power: 55 kW. Application: Chemical plant main pump, distillation column feed.
Large Bore (DN100/DN125/DN150 – Large Flow Transfer)
Methanol Pump 100-250 OH2 – DN100, 250mm impeller, very large flow medium pressure. Capacity/Head: 120–220 m³/h / 70–110 m. Power: 160 kW. Application: Tank farm transfer, long-distance pipeline.
Methanol Pump 150-315 OH2 – DN150, 315mm impeller, extra-large flow. Capacity/Head: 300–550 m³/h / 90–140 m. Power: 450 kW. Application: Plant-wide circulation, export pumping.
Note: Full 20-model lineup available (40-250, 40-315, 50-160, 50-200, 50-250, 65-160, 65-200, 65-250, 65-315, 80-160, 80-200, 80-250, 80-315, 100-200, 100-250, 100-315, 100-400, 125-250, 125-315, 150-315, 150-400). Contact for complete datasheet.
6. Selection Notes (Methanol-Specific – Critical)
NPSH (Cavitation margin): Must have NPSHa ≥ NPSHr + 1.5 m (≥2.0 m for high temperature). Add inducer or lower installation height if needed.
Explosion protection & static electricity: Full metal grounding, reliable bonding – anti-static design for seals and bearings. Motor/electrical per Ex d IIB T4.
Seal plan: Prefer double mechanical seals + Plan 53A to prevent methanol leakage. Single seals prohibited in hazardous areas.
Material: Do not use carbon steel (corrosion + rust debris). Avoid conventional rubber (swelling).
Operating range: Keep operating point within high-efficiency zone (design flow ±10%) to avoid low-flow overheating and cavitation.
7. Contact Us
For detailed technical datasheets, model selection assistance (free selection report with methanol temperature, flow/head, operating pressure), 3D models (STEP/IGES), certification documents (API 610, explosion-proof, NACE MR0175), and customized solutions (low-NPSH inducer, high-temp version, leak-free magnetic drive), please contact:
Email: info@hyrig.com
Our engineering team responds within 24 hours with API 610 compliant solutions tailored to your methanol transfer and processing needs.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.