A circulating water pump is a single‑stage centrifugal pump used to move water through a closed or semi‑closed loop – such as heating systems, chilled water networks, condenser water circuits, or cooling towers. Unlike booster pumps that increase pressure from a supply source, circulation pumps overcome the frictional resistance of pipes, valves, heat exchangers, and coils to maintain a steady flow. They are typically designed for continuous duty and low‑to‑medium head applications.
Our circulating water pumps are available in two main configurations:
Horizontal end suction (foot‑mounted) – Conforms to ISO 2858 / EN 733, heavy‑duty industrial design, flows to 2,000 m³/h.
Vertical inline (closed‑coupled) – Installs directly into the pipeline, saves floor space, flows to 1,500 m³/h.
Both types feature back pull‑out design, mechanical seal, high‑efficiency impeller, and IE3 motor as standard (IE4/IE5 optional).
| Parameter | End Suction Horizontal | Vertical Inline |
|---|---|---|
| Flow range | 10 – 2,000 m³/h | 10 – 1,500 m³/h |
| Head range | 5 – 100 m | 5 – 90 m |
| Liquid temperature | –20 to +120°C | –20 to +120°C |
| Pressure rating | Up to 16 bar | Up to 16 bar |
| Motor power | 1.1 – 250 kW | 0.55 – 160 kW |
| Efficiency | Up to 85% at BEP | Up to 83% at BEP |
| Speed | 1,450 / 2,900 rpm | 1,450 / 2,900 rpm |
| Materials | Cast iron (standard) , 304/316 SS | Cast iron (standard) , 304/316 SS |
Horizontal End Suction (ISO 2858)
Foot‑mounted, single‑stage, single‑suction.
Ideal for high flow, medium head applications.
Back pull‑out design – replaces seal/impeller without removing piping.
Requires baseplate and grouting.
Vertical Inline
Direct‑coupled motor on top of pump casing.
Installs between pipe flanges – no baseplate needed.
Ideal for space‑constrained mechanical rooms, high‑rise buildings.
Supports heavy pipes via flanges.
| Component | Standard (cast iron) | Upgrade (stainless) |
|---|---|---|
| Casing | Cast iron GG25 epoxy coated | 304 SS / 316L SS |
| Impeller | Cast iron or bronze | 304 SS / 316L SS |
| Shaft | 2Cr13 or 420 stainless | 304 SS / 316 SS |
| Mechanical seal | Carbon vs. ceramic (NBR) | Silicon carbide vs. carbon (Viton) |
| Wear rings | Cast iron / bronze | Stainless steel hard‑faced |
For closed loops with inhibited water, cast iron is economical. For open cooling towers (exposure to air, chlorides) or seawater, specify stainless steel.
| Service | Seal faces | Elastomer | Plan |
|---|---|---|---|
| Chilled water (5‑15°C) | Carbon vs. ceramic | NBR | Plan 11 (self‑flush) |
| Hot water (60‑90°C) | Silicon carbide vs. carbon | Viton | Plan 11 or Plan 21 |
| Cooling tower water (dirty) | Silicon carbide vs. silicon carbide | Viton | Plan 32 (external flush optional) |
| Sector | System | Pump type |
|---|---|---|
| HVAC | Chilled water circulation (building cooling) | Horizontal or vertical inline |
| HVAC | Hot water heating (radiators, fan coils) | Vertical inline (small footprint) |
| Power / industrial | Cooling tower condenser water | Horizontal end suction (high flow) |
| Industrial | Process cooling loops (machinery, compressors) | Horizontal end suction |
| District heating/cooling | Primary network circulation | Horizontal end suction (large sizes) |
| Solar thermal | Circulation through collectors and storage | Vertical inline (stainless steel) |
High efficiency – Hydraulically optimised impeller and volute achieve up to 85% efficiency.
Low noise – Precision‑balanced rotor, rigid shaft, heavy bearings → <75 dB(A) at 1 m.
Easy maintenance – Back pull‑out (horizontal) or spacer coupling (vertical inline) allows seal replacement without moving motor.
Space‑saving – Vertical inline version reduces footprint by 50‑70%.
VFD ready – Suitable for variable frequency drive; soft start and energy saving.
Corrosion resistant – Epoxy coating or stainless steel options for aggressive water.
Hydrostatic test: 1.5x design pressure.
Performance test: ISO 9906 Grade 3 (or Grade 2 on request) – flow, head, power, efficiency.
Mechanical run test: 1 hour.
Material certification: EN 10204 2.2 (3.1 optional).
Piping support – Independent supports; do not rely on pump flanges.
Suction pipe – Use eccentric reducer (flat on top) to prevent air pockets.
Check valve – Install on discharge to prevent backflow when pump stops.
Strainer – Recommended for open cooling tower circuits to protect pump from debris.
| Task | Frequency |
|---|---|
| Check mechanical seal for leaks | Monthly |
| Grease motor bearings (if grease fittings) | Every 6 months |
| Replace mechanical seal | 8,000‑12,000 hours or when leaking |
| Clean strainer (if fitted) | 3‑6 months |
| Problem | Likely cause | Solution |
|---|---|---|
| Pump does not deliver water | Not primed, suction valve closed, impeller blocked | Prime, open valve, clean impeller |
| Low flow / head | Worn wear rings, clogged impeller, air in suction | Replace wear rings, clean impeller, vent air |
| Excessive noise / vibration | Cavitation, misalignment, worn bearings | Increase NPSHa, re‑align, replace bearings |
| Motor overload | Specific gravity too high, viscosity too high, flow too high | Check fluid; throttle discharge valve |
Wide hydraulic range – Flows to 2,000 m³/h, heads to 100 m – covers most HVAC and industrial circulation duties.
High efficiency – Up to 85% reduces operating costs over long service life (20+ years).
Flexible configuration – Horizontal or vertical inline, cast iron or stainless steel.
Easy service – Back pull‑out design standard.
VFD ready – Energy efficient partial load operation.
CE certified – Conforms to European standards.
| Component | Recommended Quantity |
|---|---|
| Mechanical seal kit | 1 set |
| Bearing set (motor side) | 1 set |
| Impeller | 1 (optional) |
| Wear rings (if fitted) | 1 set |
| Gasket / O‑ring kit | 1 set |
For detailed selection of the correct circulating water pump – including flow and head requirements, fluid temperature, pipe system layout, and material – please contact our engineering team.