A demineralized water pump (also called a deionized water pump, DI water pump, or demin water transfer pump) is a centrifugal pump specifically designed to handle high‑purity water that has had its mineral ions removed (e.g., through ion exchange or reverse osmosis). Demineralized water is highly corrosive to carbon steel because it lacks buffering ions and readily absorbs carbon dioxide from the air, forming carbonic acid (H₂CO₃). This lowers the pH to 5.5‑6.5, causing rapid rusting of standard cast iron or carbon steel pumps. Our pumps use 316L stainless steel wetted parts to prevent corrosion, maintain water purity, and avoid iron contamination that could damage downstream equipment such as deaerators, boilers, or high‑pressure steam generators.
These pumps are fully compliant with API 610 11th/12th edition (ISO 13709) , offering a 20‑year design life and minimum 3‑year uninterrupted operation. They are suitable for demineralized water transfer in power plants, refineries, petrochemical facilities, RO plants, and industrial boiler feed systems.
| Pump Type | API 610 Type | Best Application |
|---|---|---|
| OH2 | Overhung, centreline‑mounted, single‑stage | General demin transfer from storage tanks to deaerator or process (heads ≤150 m) |
| BB3 | Axially split, single casing, multistage, between bearings | High‑head demin water boosting to elevated deaerators or high‑pressure boiler feed (heads up to 400 m) |
| VS4 | Vertical suspended sump / can type | Below‑grade demin water pits; low NPSHa installations |
Single‑stage, overhung impeller, centreline mounted.
Back pull‑out design – removable rotating assembly without disturbing piping.
Flow to 600 m³/h, head to 150 m (260 m with high‑speed or larger impeller).
Ideal for demin transfer from storage to deaerator, or to process users.
Multistage (3‑10 stages) for heads up to 400 m.
Opposed back‑to‑back impellers – axial thrust self‑balancing.
Axially split casing – full rotor access without removing piping.
Used for pumping demin water to tall deaerators or directly into high‑pressure boiler feed pumps.
| Parameter | OH2 | BB3 | VS4 |
|---|---|---|---|
| Flow range | 10 – 600 m³/h | 20 – 500 m³/h | 10 – 400 m³/h |
| Head range | 20 – 150 m (260 m max) | 50 – 400 m | 15 – 100 m |
| Max temperature | 120°C | 120°C | 100°C |
| Pressure rating | Up to 25 bar | Up to 40 bar | Up to 16 bar |
| Speed | 1,450 / 2,950 rpm | 1,450 / 2,950 rpm | 1,450 / 2,950 rpm |
All wetted parts are 316L stainless steel (API 610 Class S‑8) as standard to prevent metallic contamination and corrosion.
| Component | Material |
|---|---|
| Casing | 316L stainless steel (CF3M) |
| Impeller | 316L stainless steel |
| Shaft | 316 stainless steel or 17‑4 PH |
| Wear rings | 316L + Stellite hard‑faced |
| Gaskets | PTFE or spiral wound graphite |
| Fasteners | 316 stainless steel |
Carbon steel is never used for demineralized water service. If a lower cost alternative is needed for very low solids, specify 304 stainless steel, but 316L is preferred for maximum resistance to low‑pH corrosion.
| Service | Recommended Seal | API Plan | Remarks |
|---|---|---|---|
| Cold demin water (≤50°C) | Single cartridge | Plan 11 (self‑flush) | Carbon/ceramic, EPDM or Viton |
| Warm demin water (50‑90°C) | Single with cooled flush | Plan 23 (recirculation cooler) | Silicon carbide vs. carbon, Viton |
| High‑temperature demin (>90°C) | Single or tandem | Plan 23 or Plan 52 | Prevent flashing at seal faces |
Seal faces: Carbon vs. ceramic for cold water; Silicon carbide vs. carbon for hot water. Elastomers: EPDM (standard for cold) or Viton (FKM) for higher temperatures.
Demineralized water has low conductivity and is very aggressive to carbon steel. It readily absorbs CO₂ from the atmosphere, forming carbonic acid (pH 5.5‑6.5). Even stainless steel can experience crevice corrosion if chlorides are present or if surface finish is poor. Our 316L SS pumps are electropolished to a smooth finish (Ra ≤0.8µm on request) to minimise corrosion risk.
No rust particles – protects downstream deaerator, boiler, and steam turbine.
Viton/EPDM seals – avoid rubber that leaches contaminants.
No bronze or brass (copper alloys) – copper contamination can cause catalytic decomposition in high‑pressure boilers.
Demin water is often stored in atmospheric tanks, and the pump may take suction with limited NPSHa (2‑5 m). Because demin water is low‑viscosity and near‑boiling point in some cases (deaerator feed), we offer:
Inducer option (reduces NPSHr by 40‑60%).
Double‑suction first stage impeller (for larger OH2 pumps).
VS4 vertical sump for below‑grade tanks.
| Industry | Application |
|---|---|
| Power generation | Demin water transfer from storage to deaerator; boiler feed booster |
| Refining & petrochemical | Demineralized water for steam generation, wash water, chemical dilution |
| Reverse osmosis / water treatment | Transfer of RO permeate to demin tanks or EDI units |
| Industrial boiler plants | Boiler feedwater polishing and transfer |
| Pharmaceutical | Purified water (PW) distribution (higher grade 316L electro‑polished) |
| Semiconductor | Deionized water for wafer rinsing (ultra‑pure grade) |
Design life: 20 years minimum
Continuous operation: Minimum 3 years uninterrupted service
Bearing life: L10 ≥25,000 hours
Critical speed: ≥120% of maximum operating speed
Centreline mounting (OH2/BB3) – for thermal expansion in hot demin service
Hydrostatic test: 1.5x design pressure
Performance test: Water per API 610 Grade 1 or 2
Material certification: EN 10204 3.1 full traceability
316L stainless steel wetted parts – prevents iron contamination and corrosion in aggressive demineralized water.
API 610 full compliance – OH2, BB3, VS4 – 11th/12th edition ISO 13709, 20‑year life.
High purity design – electro‑polished options, no copper alloys, pure elastomers.
Low NPSH solutions – inducer, double suction first stage, or vertical VS4.
API 682 mechanical seals – Plan 11, Plan 23, or Plan 53B – reliable, long life.
Back pull‑out design – easy maintenance without removing piping.
Full material traceability – EN 10204 3.1 certificates for all wetted parts.
Field proven – thousands of units in power plants, refineries, and water treatment facilities.
| Component | Recommended Quantity |
|---|---|
| Mechanical seal kit (API 682 Plan 11 or 23) | 1 set |
| Bearing set (radial + thrust) | 1 set |
| Wear ring set (casing + impeller) | 1 set |
| Gasket / O‑ring kit (full set) | 1 set |
| Inducer (if fitted) | 1 set |
For detailed selection of the correct demineralized water pump – including flow and head requirements, water chemistry (pH, conductivity, chlorides), NPSHa, temperature, and material grade (316L or duplex) – please contact our engineering team.
Email: info@hyrig.com
Our engineers support power generation, refinery, petrochemical, and water treatment projects worldwide with reliable, pure‑quality API 610 demineralized water pumps – 316L stainless steel, built for 20‑year service.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.