HYRIG can supply the DF series check valve range. The DF78-70G is an upper cover plate type check valve with a 78 mm nominal bore, engineered to prevent backflow in high-pressure manifolds. The removable top cover allows for easy in-line maintenance. It is available with either a 3" FIG1502 hammer union or an API 3 1/16" flange connection.
| Model Number | Nominal Diameter | Pressure (MPa) | L (mm) | H or D (mm) | Connection Type | Type |
|---|---|---|---|---|---|---|
| DF78-70G (V1) | 78 mm | 70 | 619 | 362 | 3"FIG1502 | Cover |
| DF78-70G (V2) | 78 mm | 70 | 661 | 362 | API Flange 3 1/16" | Cover |
Data source: Technical data table.
Explore the full DF Check Valve Series.
Verify your connection type before ordering, as the overall length differs:
The flange version is 42 mm longer than the hammer union version. Ensure you have adequate space for the cover plate (362 mm height) during maintenance.
The DF78-70G utilizes a G Type (Upper Cover Plate) design. It uses a spring-loaded poppet to prevent reverse flow. The top cover plate allows for in-line inspection and replacement of the seat and poppet, saving downtime compared to full valve removal.
Replacing an older 3-inch check valve? Here is what to verify:
This valve is specifically suited for:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Not sure if you need the flanged or hammer union version? Tell us your piping interface and pressure requirements, and our engineers will confirm the correct variant.
Q: What is the difference between the two variants of DF78-70G?
A: Variant 1 uses a 3" FIG1502 hammer union (L=619 mm). Variant 2 uses an API 3 1/16" flange (L=661 mm).
Q: What is the advantage of the G type?
A: The upper cover plate allows for easier maintenance of the internal parts without removing the entire valve from the line.
Q: What is the working pressure?
A: The DF78-70G is rated for 70 MPa (10,000 psi).