HYRIG can supply the DF series check valve range. The DF series are API 6A standard check valves used in wellhead and manifold applications to prevent backflow. They are available in Dart (B), Upper Cover Plate (G), and Straight Baffle (D) types, with working pressures from 35 MPa to 105 MPa.
| Model Number | Spec (mm) | Pressure (MPa) | L (mm) | H or D (mm) | Connection | Direction / Type |
|---|---|---|---|---|---|---|
| DF52-70B | 52 | 70 | 421 | 139 | 2"FIG1502 | Standard, dart |
| DF65-70B | 65 | 70 | 491 | 160 | 2"FIG1502 | Standard, dart |
| DF52-70G | 52 | 70 | 484 | 280 | 2"FIG1502 | Standard, cover |
| DF78-70G (V1) | 78 | 70 | 619 | 362 | 3"FIG1502 | Standard, cover |
| DF78-70G (V2) | 78 | 70 | 661 | 362 | API Flange 3 1/16" | Standard, cover |
| DF103-35G | 103 | 35 | 549 | 403 | API Flange 4 1/16" | Standard, cover |
| DF103-70G | 103 | 70 | 670 | 408 | API Flange 4 1/16" | Standard, cover |
| DF52-105D | 52 | 105 | 358 | 214 | 2"FIG1502 | Standard, check |
| DF65-105D | 65 | 105 | 403 | 242 | 3"FIG1502 | Standard, check |
Data source: Technical data table.
This series covers sizes from 52 mm to 103 mm. The structural length (L) ranges from 358 mm for the high-pressure straight baffle model to 670 mm for the large 4-inch cover plate model. The "H or D" column indicates either the height (H) for cover/dart types or the outer diameter (D) for straight baffle types.
The DF series operates by allowing fluid to flow in one direction and automatically closing to prevent backflow.
Replacing an older check valve? Here is what to verify:
This series is specifically suited for:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Not sure which check valve type fits your manifold? Explore popular models like DF52-70B or DF65-70B. Tell us your flow requirements and connection type, and our engineers will confirm the exact model.
Q: What do the letters in the DF model code mean?
A: DF is Check Valve. B is Dart type, G is Upper Cover Plate type, and D is Straight Baffle type. The numbers represent Nominal Diameter (mm) and Working Pressure (MPa).
Q: What does standard direction mean?
A: Standard direction means the flow goes from the female end to the male end. If you need reverse flow, choose a model with the "F" suffix.
Q: Are different connections available?
A: Yes, models are available with FIG1502 hammer unions or API flanges (3 1/16", 4 1/16").
For DF check valve series selection, contact HYRIG: info@hyrig.com
Page last updated: 2026-11-08