HYRIG can supply the JL series choke valve range and its replacement parts. The JLK78-105 is a manual, adjustable choke valve with a 78 mm nominal bore, engineered for ultra-high-pressure flow regulation in wellhead and choke manifolds. It features a needle adjusting mode and flange connections for secure integration.
| Model Number | Nominal Diameter | Pressure (MPa) | A (mm) | B (mm) | Connection Type | Adjusting Mode | Actuator |
|---|---|---|---|---|---|---|---|
| JLK78-70 | 78 mm | 70 | 290 | 240 | Flange / Hammer unions | Cylinder | Manual |
| JLK78-105 | 78 mm | 105 | 260 | 260 | Flange | Needle | Manual |
| JLKY78-105 | 78 mm | 105 | 292.1 | 262.6 | Flange | Cylinder | Hydraulic |
Data source: Technical data table.
Need hydraulic actuation? View the JLKY78-105 Hydraulic Choke Valve or explore the full JL Choke Valve Series.
The exact footprint for the ultra-high-pressure JLK78-105 configuration is:
Note: This manual needle-adjustable model has a different footprint (260x260 mm) compared to the hydraulic cylinder model (292.1x262.6 mm). Verify your piping clearance before ordering.
The JLK78-105 utilizes a needle adjusting mode. A tapered needle moves precisely within the seat to control the flow area under extreme pressures up to 105 MPa (15,000 psi).
The "K" in the model code indicates an adjustable design. If you require hydraulic remote control instead of a manual handwheel, choose the "Y" model (JLKY78-105).
Looking for a replacement for your existing 15,000 psi choke valve? Here’s what to check:
This valve is specifically suited for:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Not sure if manual operation is safe for your 15,000 psi system? Tell us your operational requirements, and our engineers will help you determine if a hydraulic (JLKY) model is more suitable.
HYRIG provides replacement parts for the JLK78 series, including:
See our JL Choke Valve Parts page for compatible maintenance kits.
Q: What is the maximum working pressure of this valve?
A: The JLK78-105 is rated for an ultra-high working pressure of 105 MPa (15,000 psi).
Q: What adjusting mode does this use?
A: It uses a needle adjusting mode for precise flow control.
Q: Are the dimensions the same as the hydraulic version?
A: No. This manual model (JLK78-105) has a footprint of 260x260 mm, while the hydraulic version (JLKY78-105) is 292.1x262.6 mm.
Q: What standards does this valve meet?
A: It is manufactured according to API 6A and API 16C standards.
For JLK78-105 adjustable choke valve selection and replacement parts, contact HYRIG: info@hyrig.com
Page last updated: 2026-11-08