A diesel pump (also called a diesel transfer pump or fuel oil pump) is a self‑priming rotary vane or centrifugal pump specifically designed to handle diesel, biodiesel (B20, B100), kerosene, and light heating oils safely and efficiently. Unlike gasoline pumps, diesel pumps do not require explosion‑proof motors (diesel is less volatile), but they must be built with corrosion‑resistant seals and capable of handling the higher viscosity of diesel, especially in cold weather.
These pumps are widely used for:
Transferring diesel from drums, IBC tanks, or storage tanks to tractors, trucks, excavators, and generators
Refueling agricultural equipment and construction machinery
Emptying bulk storage tanks during maintenance
Supplying fuel to boilers and heaters (heating oil)
Marine refueling of workboats and yachts
Available in three drive types: 12V DC (vehicle battery), 230V AC / 110V AC (mains electricity), and manual lever (hand pump, no power required).
| Pump Type | Efficiency | Self‑Priming | Best For |
|---|---|---|---|
| Rotary vane (most common) | High | Excellent (up to 5 m lift) | Diesel, biodiesel, higher viscosity, intermittent dry running |
| Centrifugal | High (clean, low viscosity) | Moderate (flooded suction recommended) | High flow, clean diesel, permanent installations |
For portable and farm use, rotary vane pumps are preferred because they self‑prime easily, handle some dry running (carbon vanes), and maintain suction even when the tank level is low.
| Parameter | Electric 12V DC | Electric 230V AC / 110V | Manual Lever |
|---|---|---|---|
| Flow rate (max) | 30 – 60 L/min | 50 – 120 L/min | 10 – 25 L/cycle |
| Max head (pressure) | 10 – 20 m | 15 – 30 m | 5 – 10 m |
| Suction lift (dry) | 2 – 4 m | 3 – 5 m | 2 m |
| Power | 200 – 500 W | 370 – 1100 W | Hand operated |
| Inlet / outlet size | 1″ – 1.5″ | 1″ – 1.5″ | 1″ |
| Duty cycle | Intermittent (30 min) | Continuous (with thermal protection) | Unlimited |
| Hose length (included) | 4 – 5 m | 4 – 6 m | 2 m (optional) |
| Voltage | 12V DC (negative ground) | 230V / 50Hz or 110V / 60Hz | N/A |
| Max fluid temperature | 50°C | 50°C | 50°C |
| Viscosity handling | Up to 200 cSt | Up to 200 cSt | Up to 100 cSt |
| Component | Material | Reason |
|---|---|---|
| Pump housing | Cast iron (epoxy coated) or aluminium | Corrosion resistant, durable |
| Vanes (rotary vane type) | Carbon (graphite) or PTFE | Self‑lubricating, wear‑resistant, compatible with diesel |
| Impeller (centrifugal) | Bronze or stainless steel | – |
| Shaft | Stainless steel | Sealed against leakage |
| Mechanical seal | Viton (FKM) or PTFE | Diesel and biodiesel compatible (NBR swells) |
| Motor | Totally enclosed fan‑cooled (TEFC) or sealed | Suitable for outdoor/workshop use |
| Hoses | Nitrile rubber (NBR) or reinforced synthetic rubber | Diesel‑resistant |
Diesel and biodiesel cause certain elastomers (natural rubber, EPDM, standard NBR with low acrylonitrile) to swell and degrade. We use high acrylonitrile NBR or Viton (FKM) seals specifically formulated for diesel service. For biodiesel (B20, B100), Viton is strongly recommended.
Bypass valve – Internal relief valve returns fuel to suction side if discharge is closed, preventing overpressure and motor overload.
Thermal overload protection (electric models) – Motor shuts off if overheated; resets automatically or manually.
Strainer / filter – Built‑in or inline mesh strainer protects pump from debris.
Nozzle with auto‑shutoff (optional) – Stops flow when tank is full; prevents spills.
Cordless / battery clamp (12V DC) – Alligator clips connect directly to vehicle or equipment battery.
IP55 / IP65 motor protection – Dust and water resistant for outdoor use.
Grounding lug – For static electricity dissipation (recommended when pumping into plastic containers or in dry conditions).
| Application | Recommended Pump Type | Features Needed |
|---|---|---|
| Refueling tractors, excavators, telehandlers on site | 12V DC rotary vane | Battery clamps, 4‑5 m hose, nozzle, strainer |
| Farm / agricultural bulk transfer from tank to bowser | 230V AC rotary vane | High flow, thermal protection, auto‑nozzle, meter (optional) |
| Generator refueling (backup power) | 12V DC or 230V AC | Compact, portable, diesel‑compatible seals |
| Heating oil transfer from storage to day tank | 230V AC centrifugal (cast iron) | High flow, continuous duty, easy installation |
| Remote site (no electricity) | Manual lever pump | Portable, no power needed, low flow |
| Boat / marine refueling | 12V DC (waterproof) | IP65 motor, marine‑grade hose, grounding |
Diesel & biodiesel compatible – Viton seals, carbon vanes, cast iron or aluminium housing.
Self‑priming – Lifts diesel from drums, underground tanks, or IBCs without manual priming.
Built‑in bypass valve – Protects pump and motor if discharge nozzle is closed.
Thermal protection – Prevents motor burnout during extended use.
High flow options – Up to 120 L/min for fast refueling of large equipment.
Portable design – Carrying handle, lightweight (10‑25 kg), suction tube included for drums.
Low voltage (12V) option – Direct connection to vehicle / machinery battery – ideal for field use.
Easy maintenance – Replaceable carbon vanes and seals, widely available spare parts.
Manual lever option – For small transfers or emergency use without power.
Meter / counter optional – For accurate inventory control.
Electric pump (12V or 230V):
Connect grounding (if recommended) – Attach grounding wire from pump to earth rod or machine chassis.
Insert suction tube – Place into diesel drum or tank; ensure foot strainer is submerged.
Attach discharge hose – Secure nozzle or plain hose with appropriate fittings.
For 12V DC – Connect red clamp to battery positive (+), black clamp to negative (–) or chassis ground. Ensure vehicle/machine is not running.
For 230V AC – Plug into RCD‑protected socket.
Prime – Turn pump on; diesel should flow within 10‑30 seconds (priming time depends on lift).
Pump – Fill vehicle tank, bowser, or container.
After use – Run pump for a few seconds with suction tube in air to clear remaining diesel (for rotary vane pumps). Turn off, disconnect power.
Manual lever pump:
Insert suction tube, place discharge into target container.
Pump handle until diesel flows.
Return handle to lowest position after use.
Important notes for biodiesel (B20, B100):
Biodiesel has higher solvent properties and may dissolve old deposits. Clean tank and hoses before first use.
Monitor seal condition; consider upgrading to Viton seals if not already fitted.
| Task | Frequency |
|---|---|
| Check hoses and fittings for cracks or leaks | Before each use |
| Clean inlet strainer | Monthly or when flow reduces |
| Replace carbon vanes (rotary vane pumps) | 500 – 800 hours or annually |
| Replace mechanical seal | When leaks appear (every 2‑3 years) |
| Inspect electrical cable and plug (electric) | Every 6 months |
| Drain water from suction strainer (if condensation) | Seasonally |
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump runs but no flow | Loss of prime, blocked strainer, worn vanes, air leak | Re‑prime; clean strainer; replace vanes; tighten suction joints |
| Low flow | Partially blocked hose or strainer, low battery voltage (12V), diesel too cold (viscous) | Clear blockage; charge battery; use winter diesel or warm pump |
| Motor hums but doesn't run (12V) | Low battery, poor connection, stuck vanes | Charge battery; clean terminals; tap pump body to free vanes |
| Leaking at shaft seal | Seal incompatible with biodiesel or worn | Replace with genuine Viton seal kit |
| Overheating (electric) | Run dry, duty cycle exceeded, blocked cooling | Ensure prime; let cool; reduce runtime; clean motor vents |
| Component | Recommended Quantity |
|---|---|
| Carbon vane set (rotary vane type) | 1 set |
| Mechanical seal (Viton) | 1 set |
| Strainer / filter | 1 |
| Hose with nozzle | 1 as spare |
| Outlet nozzle (manual or auto) | 1 |
Diesel‑optimised – Viton seals, carbon vanes, cast iron or aluminium housing withstands diesel and biodiesel.
Versatile power options – 12V DC (battery), 110V / 230V AC, or manual lever.
High flow options – Up to 120 L/min for fast refueling.
Built‑in bypass valve and thermal protection – Prevents damage.
Portable and rugged – Designed for farm, construction, and industrial use.
Easy to maintain – Standard vane kits and seals widely available.
Global voltage compatibility – 12V, 110V, 230V, 50Hz/60Hz.
For detailed selection of the correct diesel pump – including flow rate, suction lift, power source (12V, 110V, 230V, manual), hose length, and accessories (meter, auto‑nozzle) – please contact our engineering team.
Email: info@hyrig.com
Our engineers support agricultural, construction, industrial, and marine diesel transfer projects worldwide with reliable, self‑priming diesel pumps – built for diesel, biodiesel and light fuel oils.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.