API 610 VS1 vertical multistage turbine pump for fire water pumping from deep wells, reservoirs, wet pits, or open water sources. Single casing diffuser type, line shaft construction. Provides reliable high pressure fire protection flow. NFPA 20 compliance available. Suitable for refinery, petrochemical, power plant, and industrial fire water systems. Manufactured in China with API 610 11th Edition compliance.

Conatct For Details
DetailReview(0)Additional

Overview & Definition

The Fire Water Pump is an API 610 Type VS1 vertical, single casing, multistage turbine pump specifically engineered for fire protection water supply from wells, reservoirs, rivers, or wet pits. The pump fully complies with API 610 11th Edition and ISO 13709 standards, with optional compliance to NFPA 20 for fire pump service.

In fire protection systems, the VS1 pump draws water from a static source (dedicated fire water tank, river, pond, or deep well) and delivers it at required pressure to the plant fire water ring main, hydrants, sprinklers, or deluge systems. The vertical turbine configuration is preferred when suction conditions are insufficient for horizontal fire pumps or when the water source is below grade.

The VS1 design features a submerged bowl assembly below minimum water level, line shaft transmitting power from above-grade driver, and multistage impellers providing required pressure. This eliminates priming concerns and cavitation risks associated with suction lift.

As a specialized China API 610 pump manufacturer, we produce VS1 fire water pumps for critical fire protection service in refineries, petrochemical complexes, power plants, and industrial facilities.

Media Compatibility

MediumSuitability
Clean fresh waterExcellent – standard construction
Raw water / River waterGood – with strainer and moderate solids tolerance
Sea water / Brackish waterGood – with duplex stainless steel or bronze
Fire water with additivesGood – with compatible materials (AFFF foam concentrate compatible)

The pump is designed for clean or slightly polluted water as typically encountered in fire water storage.

Product Parameters

ParameterRange
Flow rate (Q)50 ~ 5,000 m³/h (typical fire pump ratings)
Total head (H)50 ~ 200 m (7 ~ 30 bar)
Operating temperature-20°C ~ +80°C
Design pressureUp to 2.5 MPa (25 bar)
Speed1,450 / 2,980 rpm (50 Hz) or 1,750 / 3,550 rpm (60 Hz)
Flange ratingASME Class 150 / 300
Installation depthUp to 30 m

Design Features

FeatureBenefit
Vertically suspended submerged pumpImpeller always submerged – no priming required, no suction lift issues
Multistage diffuser typeDevelops required fire water pressure through stacked stages
Single or double suction first stageSingle suction standard; double suction for ultra low NPSH applications
Line shaft with centralizersTransmits torque from driver to submerged bowl assembly; centralizers prevent shaft vibration
Stainless steel column pipeThreaded or flanged connections; corrosion resistant for long service life
Axial thrust balancingBalance drum or thrust bearing in discharge head handles hydraulic thrust
Renewable wear ringsMaintains efficiency over pump life
Packed stuffing box or mechanical sealSeal at discharge head prevents leakage along shaft; mechanical seal optional for zero emissions
Material optionsCast iron, bronze, 304/316SS, duplex for corrosion resistance
Driver optionsElectric motor (standard), diesel engine (NFPA 20 requirement often), or steam turbine
NFPA 20 complianceOptional: diesel engine drive, overspeed protection, pressure relief, full fire pump controller

Materials of Construction

ComponentFresh Water ServiceSea Water / Corrosive Service
Bowl castingCast iron316SS / Duplex
ImpellersBronze (ASTM B148)316SS / Duplex / Super Duplex
DiffusersCast iron / Bronze316SS / Duplex
Line shaftAISI 416 stainless steel17-4PH / Duplex
Column pipeCarbon steel (FM approved)316SS / Duplex
Discharge headCast iron / Fabricated steel316SS
Wear rings / BushingsBronze / Silicon carbideSilicon carbide / Stellite

Fire Protection Standing

  • Compliant with API 610 for heavy duty continuous service

  • Optional NFPA 20 compliance for fire pump installations

  • Factory Mutual (FM) or UL listed upon request (subject to certification process)

  • Diesel engine drive option for reliable power during electrical failure

  • Complete fire pump package: pump, driver, controller, relief valve, gauges, and piping

Applications

IndustryFire Water Service
Oil refineriesFire water main supply from storage tanks or wells
Petrochemical plantsProcess area deluge and hydrant systems
LNG / Gas processingCritical fire protection from deep wells
Power plantsCooling tower fire protection, station service water
Storage terminalsTank farm fire water supply
Offshore platformsSeawater lift for firewater (with duplex materials)
MiningProcess plant fire protection

Why Choose a China API 610 VS1 Fire Pump Manufacturer?

  • API 610 11th Edition (ISO 13709) compliance – rigorous design and testing

  • Optional NFPA 20 compliance – meets fire protection industry standards

  • Submerged vertical design – eliminates priming and suction lift issues

  • Multistage high pressure capability – up to 25 bar discharge

  • Complete material range – cast iron, bronze, 304/316SS, duplex for sea water

  • Competitive cost – 20–30% lower than Western alternatives

  • Lead time – 20–28 weeks for standard configurations

  • Factory testing – full performance test, mechanical run, hydrostatic test

  • Documentation – performance curves, GA drawings, test reports, material certifications

  • Complete fire pump packages – pump, driver, controller, auxiliary components

  • Spare parts – critical components stocked

Summary

ParameterSpecification
Pump TypeAPI 610 Type VS1 – vertical, single casing, diffuser, multistage turbine pump
MediumFresh water, raw water, sea water (with duplex)
Flow range50 ~ 5,000 m³/h
Head range50 ~ 200 m
Temperature-20°C to +80°C
Pressure ratingUp to 2.5 MPa (25 bar)
Speed1,450/2,980 or 1,750/3,550 rpm
CasingSingle casing, diffuser type
ImpellersEnclosed or semi-open, multistage
First stage suctionSingle suction (standard); double suction (low NPSH)
Installation depthUp to 30 m
Line shaft416 stainless steel (standard)
SealPacked stuffing box; mechanical seal optional
MaterialsCast iron, bronze, 304/316SS, duplex
DriverElectric motor (standard); diesel engine (NFPA)
ComplianceAPI 610 11th Edition; optional NFPA 20, FM, UL
CertificationAPI 610 / ISO 13709