XBSY Sand Pump FAQ

What is the no-load running limit?

No-load running time cannot exceed 5 seconds. The pump must run with liquid; otherwise the mechanical seal may be damaged.

What are the coupling alignment limits for motor direct drive?

Parallel offset no more than 0.25 mm; angular error no more than 0.12 mm.

What are the pulley alignment limits?

The two pulley axles shall be parallel with end error no more than 2 mm; the belt must be aligned and equally tensioned.

How often should bearing grease be replaced?

Replace universal lithium-based grease every 1500 hours of operation.

What is the shaft radial runout limit?

When radial runout exceeds 0.05 mm, the shaft shall be repaired or replaced.

Can the suction pipeline have a throttle valve?

No. The suction pipeline shall not be fitted with a throttle valve; a normally open valve may be used and closed only during inspection/repair.

What drive types are available?

Motor direct drive and pulley drive.

Where can I find 40SB180J part numbers?

The 40SB180J main pump and set drawing part numbers are listed on the XBSY 40SB180J parts and exploded view page.