The peripheral pump (also known as a regenerative turbine pump or side channel pump) is a specialized centrifugal pump designed to overcome the limitations of traditional centrifugal pumps in low-flow, high-head applications. While a conventional centrifugal pump loses efficiency rapidly at low flow rates, the peripheral pump maintains high efficiency and generates significant pressure through a unique hydraulic design.
The liquid enters the pump and is accelerated by a rotating impeller with numerous small vanes. As the liquid circulates through a side channel alongside the impeller, it is accelerated multiple times, gaining energy with each pass. This regenerative action produces high pressure at low flow rates with remarkably low Net Positive Suction Head (NPSH) requirements – making the peripheral pump the optimal choice for applications where space and suction conditions are challenging.
For the most critical industrial applications where failure is not an option, our peripheral pumps are engineered to meet the stringent requirements of API 610 (ISO 13709), the global standard for centrifugal pumps in petroleum, petrochemical, and natural gas industries, ensuring a 20-year design life and at least 3 years of uninterrupted service. API 610 classifies pumps into three main types: Overhung (OH), Between-Bearings (BB), and Vertically Suspended (VS). A peripheral pump can be designed as an OH2 (overhung, centerline-mounted, single-stage) for moderate head duties, or as a BB5 (double-case barrel multistage) for very high head applications requiring complete pressure containment. In practice, heavy-duty peripheral pumps for high-pressure services are built to API 610 specifications using API-approved materials like S-6, C-6, and A-8, with designs that incorporate API 610 features such as robust sealing, compliance with nozzle load requirements, and options for dual seals.
Low-Flow, High-Head Capability: Delivers exceptional pressure at low flow rates (e.g., 10 m head at just 0.5 m³/h or 143 m at 10 m³/h), ideal for boosting pressure in systems with limited flow.
Very Low NPSH Requirement: Requires as little as 0.3 to 1.2 meters of NPSH (1' to 4'), enabling operation with limited suction head and preventing cavitation.
Steady, Pulsation-Free Flow: Unlike piston pumps, the peripheral pump provides smooth, continuous discharge without pulsation, protecting downstream instruments and membranes.
High Suction Lift: Capable of lifting water up to 8 meters, making it suitable for drawing liquid from below-grade sources.
API 610 Compliance for Heavy Duty: Can be built to meet API 610 (OH2/BB5) standards with heavy-duty pressure casings, API-approved material classes, and API 682 mechanical seals.
Compact & Efficient: Small footprint with high energy efficiency, reducing installation space and operating costs.
Low Maintenance: Simple design with few moving parts, bronze/brass and SS304/316 impellers, and double-sealed precision ball bearings for long service life.
| Parameter | Range |
|---|---|
| Flow Capacity | 0.5 to 300 m³/h (up to 1,320 GPM) |
| Head (Pressure) | Up to 1,400 m (4,600 ft) |
| Maximum Pressure | Up to 100 bar (1,450 PSI) |
| Temperature Range | -20°C to +150°C |
| Maximum Speed | Up to 3,600 rpm |
| Discharge Sizes | 40 mm to 150 mm (1.5" to 6") |
| API 610 Type | OH2 (single-stage overhung) or BB5 (double-case barrel multistage) |
| Material Classes | S-6, C-6, A-8, and other API 610 Table H materials |
| Sealing | API 682 compliant (Plan 11, 21, 53B, etc.) |
| Design Life | 20 years minimum |
| Uninterrupted Run | Minimum 3 years |
The API 610 compliant peripheral pump covers broad hydraulic performance: the OH2 configuration handles flows up to 300 m³/h and heads up to 400 m in a single stage; the BB5 barrel multistage configuration reaches heads of 1,400 m for the most demanding high-pressure low-flow services. All wetted parts meet API 610 standards (C-6, A-8, S-6 classes) with options for corrosion-resistant alloys.
| Seal Arrangement | API 682 Plan | Application |
|---|---|---|
| Single Cartridge Seal | Plan 11 or 21 | Clean, non-hazardous water, low pressure |
| Tandem Seal | Plan 52 | Low to moderate risk of leakage |
| Dual Pressurized Seal | Plan 53B | Recommended for BB5 – zero emissions, high-pressure, hazardous service |
| Component | Standard Material | Upgrade Option |
|---|---|---|
| Casing (OH2) | Cast iron / Bronze / 304 SS | 316L SS (S-6), Duplex (D-1/D-2) |
| Outer Barrel (BB5) | Carbon steel (Class II) or low-alloy steel | 316L SS clad, Duplex |
| Impeller | Brass / Bronze / 304 SS | 316L SS, Super Duplex (U-8) |
| Shaft | Stainless steel (EN 1.4301 / AISI 304) | EN 1.4401, EN 1.4462, EN 1.4410 |
| Mechanical Seal | Carbon / Ceramic / Viton | Silicon Carbide / Tungsten Carbide / Aflas |
| Fasteners | Zinc-plated steel / SS304 | SS316 / Hastelloy |
Boiler Feed Water: High-pressure feed to industrial and marine boilers.
Reverse Osmosis (RO): Boosting pressure in water purification systems.
Condensate Return: Transferring hot condensate back to boiler feed tanks.
High-Pressure Circulation: Lubrication, cooling, and hydraulic systems.
Pressure Boosting: Municipal and industrial water networks.
Low-Flow Transfer: Chemical dosing, fuel transfer, small-capacity/shunt lines.
API 610 Process Services: Refinery booster pumps (lean amine, crude oil, water injection) when high head at low flow is required.
Industry-Leading Efficiency: Delivers high head at low flow without sacrificing performance or reliability.
Low NPSH: Eliminates cavitation risks in suction-lift or low-NPSHa installations.
API 610 Built: Available in heavy-duty API 610 configurations – OH2 (single-stage) and BB5 (multistage barrel) for critical service.
Broad Hydraulic Coverage: Single- and multistage designs for flows from 0.5 to 300 m³/h, heads to 1,400 m.
Seal Flexibility: Compatible with all API 682 plans, including Plan 53B for zero emissions.
Rugged Construction: Built for continuous duty in harsh industrial and marine environments.
Global Support: Spare parts and field service available through our worldwide network.
For detailed selection of the correct peripheral pump (OH2 or BB5) – including hydraulic sizing (low flow, high head), NPSHa verification, material selection per API 610 Table H, API 682 seal plan determination, and complete API 610 data sheet – please contact our engineering team.
Email: info@hyrig.com
*Our engineers support high-pressure pumping applications worldwide – from low-flow booster to heavy-duty API 610 process services.*
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.