The Self-Priming Peripheral Pump (also known as a self-priming regenerative turbine pump or self-priming side channel pump) combines the low-flow, high-head capabilities of a peripheral pump with an integral priming system that automatically evacuates air from the suction line and creates a vacuum to draw liquid upward. This makes the pump ideal for applications involving intermittent operation, suction lift conditions, air-entrained liquids, or installations where a flooded suction is unavailable.
Unlike standard peripheral pumps that require a flooded suction or a foot valve to retain liquid, the self-priming design incorporates a liquid reservoir (priming chamber) within the casing. During start-up, the pump recirculates stored liquid through the impeller, creating a vacuum that draws air from the suction line. Once the suction line is filled, the pump transitions to normal peripheral pumping operation.
For the most demanding industrial and process applications – including refinery tank truck unloading, chemical transfer from drums or tanks, condensate return from below-grade pits, and emergency sump pumping – our self-priming peripheral pumps are engineered to meet the stringent requirements of API 610 11th/12th edition (ISO 13709) . Available in OH2 (overhung, centerline-mounted, single-stage) and BB5 (double-case barrel multistage) configurations, these pumps deliver API 610 reliability, a 20-year design life, and minimum 3-year uninterrupted operation – even in self-priming, intermittent duty cycles.
Initial State: The pump casing contains a reservoir of liquid (from previous operation or manual filling). The suction line is empty.
Start-up: The impeller rotates, creating a pressure differential. Liquid recirculates within the casing while the impeller vanes act as a gas compressor, evacuating air from the suction line through the recirculation port.
Priming: Air is discharged through the discharge line. The vacuum draws liquid up the suction line.
Normal Operation: Once liquid reaches the impeller, the pump transitions to standard peripheral (regenerative turbine) pumping mode, delivering high head at low flow.
This self-priming capability eliminates the need for foot valves, vacuum pumps, or manual priming – a significant advantage for mobile or intermittent services.
| Pump Type | Configuration | Best Self-Priming Application |
|---|---|---|
| OH2 (Preferred) | Overhung, centerline-mounted, single-stage, with integral priming chamber | Low-to-medium head self-priming duties (heads ≤400 m); tank truck unloading; drum transfer; condensate return from pits |
| BB5 | Double-case barrel, radially split, multistage, with self-priming attachment | High-head self-priming duties (heads >400 m, up to 1,400 m); remote fuel transfer; high-pressure intermittent injection |
The OH2 configuration is the most common for self-priming peripheral pumps because the overhung design allows easy integration of a priming chamber. The BB5 configuration is selected for extremely high head requirements where a single-stage cannot provide sufficient pressure, and where the double-casing design provides additional pressure containment.
| Parameter | OH2 (Single-Stage) | BB5 (Multistage Barrel) |
|---|---|---|
| Flow range | 1 – 200 m³/h | 5 – 150 m³/h |
| Head range | 20 – 400 m | 100 – 1,400 m |
| Pressure rating | Up to 40 bar | Up to 150 bar |
| Temperature range | –20°C to +150°C | –20°C to +150°C |
| Self-priming suction lift | Up to 7.5 m (25 ft) | Up to 6.5 m (21 ft) |
| Maximum speed | 1,450 / 2,950 rpm | 1,450 / 2,950 rpm |
| Discharge sizes | 25 mm to 100 mm (1" to 4") | 40 mm to 100 mm (1.5" to 4") |
| Feature | Specification |
|---|---|
| Maximum suction lift (clean water) | 7.5 meters (25 feet) |
| Priming time (at 7.5 m lift) | 60–120 seconds (depending on pipe diameter and length) |
| Maximum air handling capacity | Significant – able to pump air-liquid mixtures without losing prime |
| Re-priming after temporary air ingestion | Automatic – no operator intervention required |
| Minimum liquid in priming chamber | Maintains prime during off periods (if properly installed) |
The self-priming peripheral pump handles clean liquids – water, condensate, light hydrocarbons, chemicals, and some amines. Material selection follows API 610 Table H.
| Component | Standard Material (API 610 Class) | Upgrade Option |
|---|---|---|
| Casing (OH2) | 316L stainless steel (S‑6 / S‑8) | Duplex (D‑1/D‑2) |
| Outer barrel (BB5) | Carbon steel (Class II) with 316L cladding | Duplex, Super Duplex |
| Impeller | 316L SS | Duplex, 17‑4 PH |
| Shaft | 316 SS or 4140 with coating | 17‑4 PH, Duplex |
| Wear rings | 316L SS + Stellite | Tungsten carbide |
| Priming chamber internals | 316L SS | Duplex |
| Gaskets / O‑rings | Spiral wound (graphite) / FKM | Aflas for higher temperatures |
For hydrocarbon service or sour water, NACE MR0175 / ISO 15156 certification is available.
Because self-priming pumps may run intermittently and experience air ingestion, the mechanical seal must tolerate transient dry running and variable pressures. Standard single seals are acceptable for clean, non-hazardous liquids. For H₂S or flammable service, dual seals are required.
| Seal Arrangement | API 682 Plan | Application |
|---|---|---|
| Single cartridge seal (Arr. 1) | Plan 11 (self-flush) | Clean water, condensate, light oil – standard |
| Single seal with external flush | Plan 32 | Abrasive or solids‑laden liquids |
| Tandem seal (Arr. 2) | Plan 52 | Low‑risk hydrocarbon service |
| Dual pressurised (Arr. 3) | Plan 53B | Recommended for H₂S or flammable liquids – zero emissions |
For self-priming pumps, Plan 11 is simple and effective because the pump self-flushes from its own discharge. However, if the pump runs dry during priming, the seal may overheat – specify seal faces that can tolerate brief dry running (silicon carbide vs. carbon with dry‑run capability or tungsten carbide).
The self-priming design eliminates NPSH problems during start-up because the pump does not rely on flooded suction. Once primed and operating continuously, standard peripheral pump NPSH rules apply. However, the self priming mechanism itself requires sufficient liquid in the priming chamber. Ensure the suction line is properly sized and sealed to prevent air leaks (which will destroy the priming capability).
Maximum suction lift: 7.5 meters at sea level (reduces at higher altitudes or with hot liquids)
Suction pipe sizing: Should be at least the pump suction nozzle size; larger pipes increase priming time
Foot valve: Not required (self‑priming eliminates the need), but a strainer is recommended to prevent debris entry
| Industry | Application | Liquid |
|---|---|---|
| Refinery / bulk plant | Tank truck unloading | Gasoline, diesel, kerosene, light crude |
| Power plant | Hot condensate return from below‑grade pits | Condensate (up to 150°C) |
| Marine / shipboard | Bilge pumping, fuel oil transfer | Water, fuel oil |
| Chemical plant | Drum and tote pumping | Chemicals, solvents, acids (with appropriate materials) |
| Water treatment | Pumping from sumps or tanks under suction lift | Water, wastewater |
| Agriculture / irrigation | Fuel transfer from storage tanks | Diesel, kerosene |
| Oil & gas | Produced water transfer from low‑point pits | Produced water with oil |
| Emergency systems | Standby pumping from underground tanks | Water, fuel |
Design life: 20 years minimum
Continuous operation (if required): Minimum 3 years uninterrupted service
Bearing life: L10 ≥25,000 hours
Critical speed: ≥120% of maximum operating speed
Centerline mounting (OH2/BB5): Maintains alignment during thermal cycling
Hydrostatic test: 1.5x design pressure
Performance test: Water per API 610 Grade 1 or 2
Material certification: EN 10204 3.1 (full traceability)
NACE MR0175 / ISO 15156 available for sour hydrocarbon service
API 610 compliance (OH2 / BB5) – 11th/12th edition ISO 13709, 20‑year life
Self-priming capability – Automatic priming up to 7.5 m suction lift; no foot valves or manual filling required
Low-flow, high-head performance – Handles conditions where standard centrifugal pumps fail
316L stainless steel (S‑6/S‑8) as standard – Corrosion‑resistant for most industrial liquids
API 682 mechanical seals – Single (Plan 11) or dual (Plan 53B) as required
Low NPSH during normal operation – Suitable for low‑suction head once primed
Compact footprint – Self‑priming chamber integrated into casing, no external vacuum pump needed
Intermittent duty ready – Designed for frequent start‑stop cycles (typical of tank unloading and sump pumping)
Global support – Spare parts and field service available
| Component | Recommended Quantity |
|---|---|
| Mechanical seal cartridge (API 682 Plan 11 or 53B ready) | 1 set |
| Bearing set | 1 set |
| Wear ring set | 1 set |
| Gasket / O‑ring kit (full) | 1 set |
| Priming chamber cover gasket | 1 |
For selection of the correct Self‑Priming Peripheral Pump (OH2 or BB5) for your intermittent low‑flow, high‑head application – including suction lift calculation, material selection (316L SS, duplex, or NACE MR0175 for sour service), API 682 seal plan, and complete API 610 data sheet – please contact our engineering team.
Email: info@hyrig.com
Our engineers support tank truck unloading, condensate return, chemical transfer, and emergency pumping projects worldwide with reliable API 610 self‑priming peripheral pumps – automatic priming, high head at low flow.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.