A jet pump, also known as an eductor or ejector, is a simple hydraulic device that uses the kinetic energy of a high‑pressure fluid to entrain, pump or mix a secondary fluid, without any rotating parts or electrical connection. The effect relies on the Venturi principle: a high‑speed jet of motive fluid creates a pressure drop that draws in a second (suction) fluid, after which the combined stream passes through a diffuser where velocity is converted into increased pressure.
As a result, a jet pump can “pump” a fluid even when the suction source is below the pump, or when the pumped medium contains solids, abrasives or aggressive chemicals that would destroy any mechanical pump in a short time. Typical efficiencies range from 30–50% for liquids and less than 25% for viscous oils, but the absence of mechanical wear and the ability to operate in hazardous environments often makes the jet pump the most reliable choice.
A jet pump consists of three functional sections:
Converging nozzle (motive nozzle) – the pressurised motive fluid (liquid, gas or steam) accelerates and reduces pressure.
Suction chamber (mixing throat) – the low‑pressure region draws in the secondary fluid.
Diffuser – the mixed stream decelerates, converting velocity back into increased discharge pressure.
The process is summarised by the dimensional ratios used in jet pump sizing: the area ratio (nozzle exit/ throat cross‑section), the mass flow ratio (suction flow / motive flow) and the head ratio (pressure lift / motive pressure). These parameters follow the energy equations derived from the reversible Eulerian vortex theory, which an engineer uses to model performance and avoid cavitation inside the throat.
API 610 (ISO 13709) applies specifically to centrifugal pumps that have rotating impellers, shafts, bearings, mechanical seals and casings. Jet pumps contain no rotating elements, therefore they are not classified as OH, BB or VS under API 610. However, a modern jet pump fully aligns with API engineering logic in three critical ways:
Material selection – jet pump nozzles and throats can be manufactured from API 610 Table H materials (S‑8 316L, D‑1 2205 duplex, D‑2 2507 super duplex, C‑6 carbon steel) with NACE MR0175 compliance for sour service, matching the corrosion allowance demanded by API 610 pumps.
Pressure vessel design – the body of a jet pump can be built to ASME Section VIII, rated for the same design pressures and hydrostatic testing pressure as an API 610 barrel pump (often up to 100 bar or higher).
System integration – A jet pump is typically supplied as part of a complete pumping skid that also includes one or more API 610 centrifugal pumps providing the motive fluid. For example, in a refinery low‑flow high‑head application, an API 610 Roto‑Jet BB pump works together with a jet eductor to transfer caustic, amine or sour water without generating damaging hydraulic forces.
Hence the correct engineering statement is: Jet pump design and material quality can be specified to match the requirements of API 610 and ASME, while the jet pump itself is described as a complementary fluid‑handling component rather than a classified API 610 centrifugal pump.
| Classification | Motive Fluid | Typical Application |
|---|---|---|
| Liquid‑liquid eductor | Pressurised water / oil / amine | Pumping from atmospheric sumps, blending, agitation, tank mixing |
| Gas‑liquid ejector | Compressed air, nitrogen, hydrocarbon gas | Chemical injection, well foam‑lifting, gas assisting of liquids |
| Steam ejector | High‑pressure steam | Vacuum generation, degassing, distillation column evacuation |
| Downhole hydraulic jet pump | High‑pressure power fluid (crude oil or water) | Artificial lift for deep oil wells, well unloading, testing |
| Parameter | Typical Design Range | Remarks |
|---|---|---|
| Motive fluid pressure | 15 – 350 bar | Matches the API 610 pump discharge |
| Suction lift | Up to 8 m (liquid motive) | Higher for gas‑driven ejectors |
| Pressure recovery | 20 – 80% of motive pressure | Depends on nozzle/diffuser geometry |
| Suction flow / motive flow ratio | 0.2 – 5.0 | Liquid‑liquid eductors typically 0.5–2.0 |
| Max. suction NPSHr | 1 – 10 m of liquid (depending on velocity and area ratio) | Fluid‑specific; lower NPSHr for well‑matched nozzle |
| Materials | Carbon steel, 316L SS, Duplex 2205/2507, Inconel, Hastelloy | Conforming to API 610 Table H / NACE MR0175 |
| Nozzle bore diameter | 2 – 25 mm | Precision‑machined; often field‑replaceable |
| Working temperature | –40°C to +350°C | Depends on gaskets and body material |
Jet pumps are not governed by API 610, because they have no rotating parts. However, they are commonly designed and manufactured to:
ASME B16.5 / B16.34 – flange and pressure‑temperature ratings.
ISO 24490 – for cryogenic eductor applications (LNG, liquid nitrogen).
API 680 (venturi‑type equipment) in certain petrochemical services.
NACE MR0175 / ISO 15156 – for H₂S service when the motive or produced fluid is sour.
1. Downhole artificial lift & well unloading
Jet pumps are deployed via slickline to lift heavy oil (as low as 11°API) or to unload newly drilled wells without a rig. A recent field case in Iraq replaced costly coiled‑tubing nitrogen offloading with a hydraulically powered jet pump, achieving 2200 BPD at over 500% cost savings and eliminating seven days of rig time. In heavy oil production, jet pumps are used to lift waxy crude from exploratory wells where conventional technology would lead to frequent cavitation damage.
2. Chemical injection & additive dosing
Eductors draw corrosion inhibitors, methanol and scale inhibitors into production lines or water injection systems without the need for an electrical pump. The motive fluid is the existing pressurised pipeline stream, while the suction draws the chemical from a day tank at atmospheric pressure.
3. Tank bottom stripping & sump evacuation
A jet pump mounted on the side of a storage tank using recirculated product as the motive fluid can strip the last layer of water or sludge from the tank bottom. The device works in hazardous areas (no electricity) and directly handles viscous or abrasive residues.
4. Intermittent booster in refinery low‑flow units
Where an API 610 centrifugal pump would be inefficient or pulsating (e.g. for very low flow rates below 5 m³/h), a combination of a Roto‑Jet RO‑FT API 610 pump feeding a jet eductor provides stable low‑flow high‑head transfer for amine, caustic, wash water and reflux streams.
5. Vacuum generation & gas ejector systems
Steam jet ejectors are used in crude oil vacuum distillation, amine regenerator overhead systems (to remove acid gases) and FCC units. They create a deep vacuum without any moving mechanical parts, reducing maintenance in high‑temperature, fouling services.
6. Slurry & solids transport
Because there are no rotating clearances, a jet pump can handle light slurries, catalyst fines and sand‑laden water that would rapidly erode mechanical seals and impellers of conventional pumps.
| Service Fluid | Recommended Materials | API 610 Equivalent Class | Remarks |
|---|---|---|---|
| Sweet water, light oil | Carbon steel (A105) or cast steel | C‑6 | Cost‑effective for non‑corrosive |
| Sour water, MDEA, H₂S service | 316L stainless steel (nozzle and throat) | S‑8 (316L) | NACE MR0175 required |
| Seawater, chlorides | Duplex 2205 or Super Duplex 2507 | D‑1 / D‑2 | Pitting resistance (PREN >40) |
| Heavy corrosive acids | Hastelloy C‑276, Inconel 625 | – (exotic alloy) | For extreme chemical injection |
| Abrasive sand‑laden oil | 17‑4 PH (precipitation‑hardened) with QPQ or boron carbide clad | – | Hard face extends life |
When a jet pump is installed in an API 610 skid, the body flanges, bolting and gaskets should be specified to the same pressure class as the adjacent centrifugal pump (e.g. Class 600 or 900).
Although the jet pump does not have an impeller, cavitation can still damage the throat and the diffuser walls. Net Positive Suction Head (relative to the suction fluid) must be calculated at the centreline of the eductor. Throat cavitation occurs when the absolute pressure in the mixing zone falls below the vapour pressure of the suction liquid. It leads to pitting and efficiency loss. Key rules to prevent jet pump cavitation:
For liquid motive / liquid suction systems, ensure the available NPSH (suction fluid) exceeds the required NPSH determined by the jet pump manufacturer’s curves, typically 3–15 ft depending on area ratio.
For gas‑liquid eductors, the motive gas pressure and nozzle geometry must be chosen such that the mixture velocity in the throat does not exceed the critical velocity that induces vapour collapse.
Use the limiting flow equation (ML – limiting flow function) to model the point of incipient cavitation in the diffuser throat.
The jet pump’s mechanical simplicity – no moving parts, no seals, no motor – directly translates into extremely high mean time between failures (MTBF). Maintenance essentially consists of:
Inspecting the nozzle orifice for erosion (recommend every 500 hours of abrasive service).
Checking the throat for elliptical wear or pitting (cavitation damage).
Replacing the nozzle and possibly the diffuser when performance degrades, with typical replacement intervals of 8000–12000 hours in clean service.
Because maintenance is reduced to exchanging a few precision‑machined components, a jet pump often achieves 20‑year life with lower total life‑cycle cost than any rotating pump, especially in harsh or hazardous process environments.
| Feature | Jet Pump | Centrifugal Pump (API 610) |
|---|---|---|
| Moving parts | None (no shaft, seal, bearings) | Impeller, shaft, bearings, mechanical seal |
| Power source | Pressurised motive fluid | Electric motor / turbine (requires energy supply) |
| Hazardous area safety | Intrinsically safe (no electricity) | Requires explosion‑proof enclosure and certified motor |
| Abrasive / solids handling | Excellent (no close clearances) | Poor (rapid seal, impeller and wear ring erosion) |
| Efficiency | Low to moderate (30–50%) | High (70–85%) |
| Life‑cycle cost (hazardous / remote service) | Very low (no rotating parts to replace) | Higher (seal and bearing replacements) |
No moving parts – intrinsic reliability for continuous duty in remote oil fields and hazardous areas.
Handles abrasives and solids – where mechanical seals would fail within weeks.
Inherently safe – no electrical power required, suitable for Zone 0 and ATEX environments.
Flexible deployment – can be lowered through tubing (slickline) and retrieved without a rig.
Low capital and maintenance cost – the pump consists only of a machined nozzle, body and diffuser.
Compact installation – easily integrated onto an API 610 pump skid as an auxiliary eductor module.
For a jet pump engineered to the same reliability and material standards as API 610 equipment – including nozzle and throat sizing with JEMS or proprietary software, NACE MR0175 compliance, ASME pressure vessel rating, and integration with your centrifugal pump system – please contact our engineering team.
Email: info@hyrig.com
We supply jet pumps for artificial lift, chemical injection, low‑flow transfer and hazardous area applications, oil‑field proven and built to match your API 610 process standards.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.