The GSG 80-260 HP Lean Amine Pump is a high-pressure, multistage centrifugal pump specifically engineered for lean amine charge service in gas sweetening and refinery desulfurization units. The pump is fully compliant with API 610 11th/12th edition (ISO 13709) standards and features a BB3 (axially split, between-bearings, multistage) configuration – the industry-preferred design for high-head, high-pressure amine circulation.
The GSG 80-260 reliably delivers regenerated lean amine (MDEA, MEA, DEA) from the stripper bottom to the high-pressure absorber, handling temperatures up to 120°C and heads up to 260 meters. Its robust construction ensures 3-year uninterrupted operation and a 20-year design life, meeting the most stringent requirements of modern gas processing plants.
| Code Component | Meaning |
|---|---|
| GSG | Internal model series code for high-pressure multistage centrifugal pump (API 610 BB3 type) |
| 80 | Nominal discharge flange size DN80 (mm) |
| 260 | Rated total head: 260 meters (at nominal flow) |
| Parameter | Value |
|---|---|
| Pump type | HP Lean Amine Pump |
| API 610 configuration | BB3 (axial split, multistage, between bearings) |
| Flow range (nominal) | 50 – 80 m³/h (customizable within hydraulic envelope) |
| Rated head | Up to 260 meters |
| Number of stages | 3 – 6 stages (optimized for 260m head) |
| Speed | 2950 rpm (50 Hz) / 3550 rpm (60 Hz) |
| Temperature range | –40°C to +120°C (lean amine service) |
| Design pressure | Up to 6.4 MPa (64 bar) |
| NPSHr | < 4.0 m (with optimized first-stage impeller) |
| Efficiency | 68% – 74% (depending on duty point) |
The GSG 80-260 adopts the BB3 design – horizontal, axially split, single casing, centerline mounted. This configuration allows:
Rotor removal without disturbing suction or discharge piping
Inspection of all internal components through the upper casing half
Excellent access for maintenance
Reduces downtime during seal or bearing replacement
Opposed (back-to-back) impeller arrangement self-balances hydraulic axial thrust. No balancing disc or drum is required – eliminating a common failure point in amine service where fluid degradation products can foul balancing devices.
Double volute or diffuser-type stage casings balance radial thrust at each stage, minimizing shaft deflection and extending bearing life significantly beyond the API 610 minimum requirement of 25,000 hours.
| Component | Standard Material | Upgrade Option |
|---|---|---|
| Casing | Carbon steel (Class II) | 316L SS (S-8) |
| Impeller | 304 SS | 316L SS (S-8) / Duplex |
| Shaft | 4140 (AISI) hardened steel | 316 SS / 17-4 PH |
| Wear rings | 316 SS / hardened | Stellite / Alloy 20 |
| Gaskets | Spiral wound (graphite filled) | Flexible graphite |
For lean amine service, 316L stainless steel (S-8) is strongly recommended – carbon steel is prone to generalized corrosion and pitting, especially at temperatures above 80°C.
| Seal Type | API 682 Arrangement | Flush Plan | Application Suitability |
|---|---|---|---|
| Dual pressurized seal (cartridge) | Arrangement 3 (Type A) | Plan 53B | Recommended – zero amine emissions, barrier fluid at higher pressure than process |
| Tandem seal | Arrangement 2 | Plan 52 | Acceptable for medium pressure, non-hazardous |
| Single seal (not recommended) | Arrangement 1 | Plan 11 / 21 | Only for low-pressure, low-temperature, non-H₂S lean amine |
Plan 53B uses a bladder accumulator to pressurize barrier fluid. It is the preferred choice for major EPCs (e.g., BP, Shell, TotalEnergies) for onshore lean amine charge pumps because it:
Prevents amine vapor release to atmosphere
Does not require nitrogen supply (unlike Plan 53A)
Provides visual level indication and low pressure alarm
Eliminates risk of barrier fluid freezing in cold climates
Seal faces: Silicon carbide (SiC) / Silicon carbide
Secondary seals: FKM (Viton) or Aflas for high-temperature amine
Lean amine is the regenerated solvent leaving the stripper reboiler, typically at 110–120°C, with residual acid gas content (H₂S/CO₂) of 0.1–1.0 mol%. It has:
Density: 1,010 – 1,050 kg/m³ (depending on MDEA concentration)
Viscosity: 2 – 5 cP at operating temperature
pH: 9.5 – 11.0
Hot lean amine (>80°C) causes:
General thinning of carbon steel (0.1–0.5 mm/year)
Pitting and localized corrosion at high-velocity areas (impeller tips, wear rings)
Stress corrosion cracking with H₂S present (requires NACE MR0175 materials)
316L stainless steel (API 610 S-8) with 2-3% Mo is the proven material – used successfully in >90% of modern amine charge pumps.
Lean amine has a high freezing point (typically -10°C to -25°C depending on concentration). For plants in cold climates:
Steam tracing can create local hot spots accelerating corrosion
Electric tracing is strongly preferred for freeze protection without corrosion risk
The pump casing and seal chamber must be traced or heat-jacketed if ambient drops below freezing
When calculating available NPSH for lean amine:
Do NOT consider subcooling effects
Use bubble point pressure at pump suction temperature
NPSHa must exceed NPSHr by at least 1 meter (API 610 recommendation)
Inadequate NPSH margin is a common cause of cavitation and impeller damage in amine service
The GSG 80-260 offers a steep, stable head-capacity curve with continuous rise to shut-off – essential for parallel pump operation in amine units.
| Parameter | Typical Value |
|---|---|
| Best Efficiency Point (BEP) flow | 65 m³/h |
| Head at BEP | 260 m |
| Head at shut-off | 285 – 295 m |
| Power at BEP | 65 – 75 kW (depending on amine density) |
| Minimum continuous stable flow | 25 m³/h (without recirculation) |
Note: Actual performance may vary with amine concentration, temperature, and density. Hydraulic curves are available upon request.
Natural gas sweetening – HP lean amine charge to absorber in amine treating units (MDEA, MEA, DEA)
Refinery hydrodesulfurization (HDS) – Amine regeneration loop, lean amine injection to recycle gas scrubber
Claus tail gas treatment (TGTU) – Lean amine circulation
LNG feed gas pretreatment – CO₂ and H₂S removal upstream of liquefaction
CCUS (carbon capture) – Lean MEA/MDEA circulation in post-combustion capture plants
Full API 610 BB3 compliance – 11th/12th edition, designed for 20-year life
Optimized for lean amine – 316L SS (S-8) wetted parts standard, NACE MR0175 optional
Superior sealing – API 682 Plan 53B ready, proven zero-leakage operation
Self-balancing axial thrust – Opposed impeller design eliminates balance device fouling
Low NPSHr – First-stage impeller with large suction eye and optional inducer
Maintenance-friendly – Axial split casing allows full rotor access without removing piping
High efficiency – Diffuser-type stage design ensures >70% efficiency at BOP
Proven field history – Thousands of BB3 amine pumps in global gas plants and refineries
Baseplate: Heavy-duty steel or concrete, grouted, meeting API 610 deflection limits
Piping strain: Zero allowable at pump flanges (use pipe supports and expansion loops)
Suction strainer: 40-mesh temporary start-up strainer, removed after line cleaning
Minimum flow line: Required during low-flow conditions (bypass to amine surge tank)
Flushing: Before start-up, flush clean to remove debris
Alignment: Check thermal growth alignment after reaching operating temperature
| Component | Recommended Spare Quantity |
|---|---|
| Mechanical seal (complete cartridge) | 1 set per pump |
| Bearing set | 1 set |
| Wear ring set | 1 set |
| Gasket and O-ring kit | 1 set |
| Shaft (critical stock) | 1 per 5 pumps |
Service interval (typical):
Bearing inspection: 5,000 hours
Mechanical seal replacement: 8,000 – 12,000 hours (depending on service severity)
Major overhaul: 20,000 hours or 3 years (whichever comes first)
Hydrostatic test: Each casing tested at 1.5x design pressure
Performance test: Using water, per API 610 (Grade 1 or 2 as specified)
NPSH test: Full verification at rated speed (if specified)
Material certification: EN 10204 3.1 (full traceability)
Non-destructive examination (NDE): MPI, dye penetrant, or radiography per API 610
For a detailed pump selection, API 610 datasheets, hydraulic curve, or a complete GSG 80-260 HP lean amine pump quotation, please contact our engineering team.