The Lean Amine Charge Pump is a critical piece of rotating equipment in amine sweetening units, responsible for conveying regenerated lean amine from the stripper (regenerator) to the high-pressure absorber. As acid gases such as H₂S and CO₂ are removed from the sour gas stream, lean amine is regenerated and pressurised by these pumps to re-enter the absorption cycle. All pumps are engineered to meet API 610 11th/12th edition (ISO 13709) standards, ensuring 3-year uninterrupted operation and a 20-year service life.
| Pump Type | Construction | Best Application for Lean Amine |
|---|---|---|
| OH2 | Overhung, centerline-mounted, single-stage | Moderate flow (<600 m³/h) and moderate head requirements; compact footprint, easy seal maintenance |
| BB3 | Axially split, multistage, between bearings | High-head, high-pressure lean amine charge (head up to 1,600 m); refinery HP amine circulation; preferred by 60% of global gas plant designs |
| VS4 | Vertical suspended, sump/can type | Lean amine transfer from storage or sump; space-constrained installations; fire-code compliance (zero shaft penetration) |
BB3 configuration—such as the DVMX series—offers 4 to 14 stages in heavy-duty double volute casings, supporting flows to 600 m³/h, heads to 1,300 m, and temperatures from –40°C to +210°C with opposed impeller for axial thrust self-balancing.
Lean amine is the regenerated solvent stripped of H₂S and CO₂, returning from the stripper bottom to the absorber. Rich amine is the acid-gas-loaded solution leaving the absorber.
| Parameter | Lean Amine Charge Pump | Rich Amine Pump |
|---|---|---|
| Service temperature | 40–120°C | 40–60°C |
| Corrosivity (CO₂/H₂S) | 25–40% of rich amine (but hot) | High (fully saturated) |
| Operating pressure | Up to 100 barg (discharge) | Moderate suction, low discharge (3–6 barg after let-down) |
| Sealing Configuration | API Plan | Application |
|---|---|---|
| Dual pressurized seal (Arrangement 3) | Plan 53B (bladder accumulator–pressurised barrier fluid) | High-pressure lean amine; BP and TotalEnergies mandate this for onshore amine service |
| Tandem seal with buffer fluid | Plan 52 | Medium-pressure lean amine; common in SE Asian plants |
| Single seal | Plan 11/21 | Only for low-pressure, non-hazardous lean amine (discontinued by leading EPCs for HSE compliance) |
For high-pressure/hazardous service, Plan 53B provides barrier fluid pressurised by a bladder accumulator—higher pressure than Plan 53A, eliminates N₂ entrainment, and prevents emission of amine vapour.
| Component | Recommended Material | API 610 Class | Remarks |
|---|---|---|---|
| Casing, impeller, wear rings | 316L stainless steel | S-8 | Corrosion resistance; contains Mo (2–3%) for Cl⁻ pitting resistance |
| Shaft | 4140 / 316 SS (≤400°C) | C-6 / A-8 | Nitrided shaft preferred for wear resistance |
| NACE MR0175 | For H₂S-containing amine charge | S-8 or D-1 | Mandatory for lean amine with residual H₂S |
Lean amine at elevated temperature (≥80°C) becomes increasingly aggressive. Carbon steel has been proven inadequate—over 90% of plants that started with carbon steel have upgraded to 316SS after pitting failures.
Axial thrust balance (BB3): Back-to-back opposed impellers self-balance axial thrust, eliminating complex balance drums or discs that can foul in amine service.
Radial thrust balance: Double volute casing at each stage balances radial thrust, minimising shaft deflection and extending bearing life beyond API 610 minimum 25,000 hours.
Seal chamber: API 682 compliant, accommodating single, tandem or double cartridge seals without modification.
Inlet design: Large suction eye on first-stage impeller reduces NPSHr; when calculating NPSHa for lean amine, do not consider subcooling—the fluid must be considered at bubble point at the pump suction flange to avoid cavitation.
Flange arrangement (BB3): On lower casing half, allowing full rotor inspection without disturbing piping.
| Parameter | OH2 (Single‑Stage) | BB3 (Multi‑Stage) | VS4 (Sump) |
|---|---|---|---|
| Flow range | 30–600 m³/h | 50–1,600 m³/h | 5–300 m³/h |
| Head range | 30–250 m | 100–1,600 m | 10–180 m |
| Pressure rating | Up to 4.0 MPa | Up to 25 MPa | Up to 2.5 MPa |
| Temperature | –45°C to +260°C | –80°C to +200°C | –45°C to +120°C |
| Motor power | Up to 315 kW | Up to 5 MW | Up to 110 kW |
Actual performance curves are available upon request; derating is required for elevated amine viscosity and density variations.
Lean amine has a high freezing point. For plants operating at low ambient temperatures:
Steam tracing—commonly used—can create local hot spots that accelerate corrosion.
Electric tracing is strongly preferred for freeze protection without driving corrosion problems.
Absence of freeze protection has led to catastrophic pump casing fractures in multiple North American winter incidents.
Modern lean amine charge pumps are increasingly integrated with Power Recovery Turbines (PRT). The rich amine enters from the absorber at high pressure (50–100 barg) and flows through a PRT mechanically coupled to the lean amine charge pump driver, reducing motor power draw by up to 1,500 kW per unit.
Full API 610 compliance (8th/11th/12th edition)—OH2, BB3, VS4
316L SS (S-8) wetted parts—field-validated for 20-year amine service
API 682 dual seals with Plan 53B—zero process emissions; barrier fluid pressure independently monitored
BB3 opposed impellers—axial thrust self-balanced, no thrust-bearing overload
Double volute casing—radial loads cancelled, bearing life extended
Integration-ready—PRT coupling provisions and NACE MR0175 material options
Loss of flow detection—Proprietary low-flow bypass recirculation valve prevents dead-head runout in fluctuating absorber demand
Natural gas sweetening (amine treating for pipeline gas)
Refinery hydrodesulfurisation (HDS) and Claus tail-gas treatment
LNG feed gas pretreatment
Syngas purification (ammonia and methanol plants)
CO₂ capture (CCUS) units
For detailed pump selection, hydraulic analysis, API 610 data sheets, or a complete lean amine charge pump package—including PRT integration—please contact our engineering team.
Email: info@hyrig.com
*All performance data and engineering recommendations are based on API 610 11th/12th edition standards and align with current best practices for lean amine charge pumps in HP refinery and gas processing service.*
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.