The HS-BB2-32-200 is an API 610 BB2 single-stage, double-suction, radially split between-bearing centrifugal pump, engineered by HYRIG specifically for diesel transfer in Iran’s refineries, tank farms, and oil product storage & distribution facilities. It serves as a high‑value, 100% interchangeable domestic alternative to the Sulzer BBS 32-200, offering identical dimensions, superior hydraulic efficiency, and significant cost savings.
Designed for Iran’s 50Hz power grid (380V) and fully compliant with NIOC/POGC safety standards, this pump addresses the core characteristics of diesel: clean, low viscosity (2–8 mPa·s at 20°C), flammable (flash point 55–90°C), medium-temperature service (40–120°C), and ultra‑low sulfur content (≤10 ppm, with trace H₂S in some streams). With 1:1 dimensional interchangeability, API 682 sealing, NACE MR0175 anti‑sulfide materials, and efficiency ≥78% (3‑5% higher than Sulzer), the HS-BB2-32-200 delivers energy‑saving, safe, reliable, and low‑maintenance diesel transfer – ideal for Iran’s high‑volume refinery product transfer and tank farm loading/unloading applications.
Iranian diesel (C10–C22 hydrocarbon mixture) presents specific requirements:
Clean, low viscosity – no solids, easy to pump, but demands high efficiency for large volumes
Flammable (flash point 55–90°C) – requires reliable sealing to prevent leakage
Medium temperature (40–120°C) – typical of refinery product streams
Ultra‑low sulfur (≤10 ppm) – minimal but trace H₂S possible in some streams
Continuous, high‑flow operation – refineries and tank farms operate 24/7
The HS-BB2-32-200 is optimized accordingly:
High‑efficiency hydraulic design (≥78%) – handles large‑flow continuous transfer with minimum energy cost
API 682 Plan11 seal – leakage ≤5 ppm, safe for flammable service
Temperature range -20°C to +120°C – covers all diesel handling conditions
316L stainless steel wetted parts (standard) – resists trace H₂S and coastal corrosion
Low NPSHr ≤4.0m – avoids cavitation during high‑flow operation
| Parameter | Value | Advantage over Sulzer BBS 32-200 |
|---|---|---|
| Model | HS-BB2-32-200 | Identical model number – designed for replacement; performance curve overlap ≥98% |
| Type | API 610 BB2, double‑suction, radially split | Compliant with API 610 11th/12th edition; high pressure capacity |
| Inlet/Outlet | 80×50 mm | Same as BBS 32-200 – direct fit to existing Iranian refinery piping |
| Flow Range | 50 – 150 m³/h | Full BBS flow coverage – tank truck loading, refinery transfer |
| Head Range | 20 – 110 m | Matches short‑distance diesel pressure requirements |
| Design Pressure | 40 bar | Meets Iran’s high‑pressure hazardous fluid codes |
| Temperature Range | -20°C to +120°C | Covers all diesel handling temperatures (including mildly heated) |
| NPSH required | ≤ 4.0 m | Below industry average – prevents cavitation, ensures continuous operation |
| Motor | 50Hz, 380V (IEC standard) | Direct Iran grid connection – no VFD or transformer needed |
| Compliance | API 610, API 682, NACE MR0175 | Mandatory for NIOC/POGC projects; international anti‑sulfide certification |
| Standard Casing | S‑6 carbon steel + anti‑corrosion coating | Resists Iran’s high‑salt, dusty outdoor environment |
| Standard Wetted Parts | 316L stainless steel | Suitable for diesel with trace H₂S; corrosion‑resistant |
| Mechanical Seal | Plan11 single cartridge (API 682 Cat 2) | Optimized for clean diesel; leakage ≤5 ppm – meets Iran’s flammable fluid safety rules |
| Hydraulic Efficiency | ≥ 78% | 3‑5% higher than Sulzer – significant energy savings |
Identical mounting dimensions (center height, flange position, foundation bolt pattern) – 1:1 replica of Sulzer BBS 32-200.
No piping, baseplate, or motor modification required – replacement can be completed within 8 hours (including alignment and testing).
Performance curve overlap ≥98% – no process parameter adjustment needed. Switch during a scheduled turnaround or emergency replacement with immediate production resumption.
Hydraulic efficiency ≥78% – 3‑5% higher than Sulzer BBS 32-200.
Annual energy saving example: For a typical Iranian refinery operating 24 hours/day, 330 days/year, the efficiency improvement saves approximately $4,000–7,000 USD per year in electricity costs (depending on local tariff). Over 10 years, the savings exceed the pump purchase price.
Optimized double‑suction impeller – reduces axial thrust and bearing load, further improving long‑term efficiency.
Procurement cost 40% lower than original Sulzer BBS 32-200.
Lead time ≤45 days (vs. 120+ days for imports) – supports fast‑track Iranian EPC schedules.
Radially split casing – allows internal inspection and rotor removal without disturbing piping. Reduces maintenance downtime and local labor costs.
Middle East spare parts warehouse – emergency parts response ≤72 hours; standard spare parts supply ≤15 days. Spare part costs are 40% lower than OEM equivalents.
NACE MR0175 certified – resists sulfide stress corrosion from trace H₂S in diesel streams.
Explosion protection – Ex d IIB T4 certified for Zone 1/2 hazardous areas in Iranian refineries and tank farms.
API 682 Plan11 seal – single cartridge, leakage ≤5 ppm. Tested for flammable diesel service.
Heavy‑duty external coating – withstands Iran’s high temperature (>40°C), high humidity (Persian Gulf coast), dust storms, and UV exposure. Outdoor service life ≥8 years.
Domestic references: Over 50 units in Chinese refineries (Sinopec, CNPC) diesel transfer service – average 3+ years trouble‑free operation.
Iran reference: Successfully installed at a Persian Gulf coastal refinery diesel tank farm loading/unloading pump station. Handles ultra‑low sulfur diesel (10 ppm) with trace H₂S. Continuous operation on 50Hz grid for over 2 years – zero seal leakage, no cavitation, no bearing failure. Highly recommended by the end user.
Bilingual documentation (English & Farsi/Persian) – includes ISIRI compliance reports, Iran project reference letters. Smooth customs clearance and owner approval.
| Application | Specific Role |
|---|---|
| Refinery product diesel transfer | Ahwaz Refinery, Tehran Petrochemical Complex, Bandar Abbas Refinery – diesel from process units to storage tanks, or tanks to truck/rail loading racks. High flow, continuous duty. |
| Tank farm loading/unloading | Persian Gulf coastal terminals, inland depots – ship unloading, tank truck loading. High efficiency, reliable sealing to prevent environmental contamination. |
| Refinery process diesel circulation | FCC units, hydrotreaters – process diesel circulation at medium temperature (up to 120°C) with trace H₂S. Stable, trouble‑free operation. |
| Medium‑distance pipeline transfer | From refineries to end users (fuel stations, industrial plants) – energy‑efficient boosting for short to medium distances. |
API 610 (ISO 13709) 11th/12th Edition – design and manufacturing
API 682 (ISO 21049) – mechanical seal standards
NACE MR0175 / ISO 15156 – sulfide stress corrosion cracking resistance
ISO 9001:2015 – quality management system
ISIRI – meets Iran Standard & Industrial Research Institute requirements (smooth customs clearance)
Explosion protection: Ex d IIB T4 – suitable for Iran’s hazardous petrochemical zones
Grid compatibility: 50Hz motor, 380V voltage – direct connection without transformer
7×24 technical support – via HYRIG Middle East partner service center
Fault response ≤72 hours – on‑site or remote video guidance
Spare parts supply ≤15 days for common wear parts (mechanical seals, bearings, gaskets)
Full documentation package – English/Persian IOM manuals, inspection reports, certificate of origin, ISIRI clearance documents, material test certificates (MTC)
HYRIG supplies a full range of API 610 centrifugal pumps for the oil, gas, petrochemical, and refinery industries:
OH2 – overhung, centerline mounted
BB2 – between‑bearing, radially split, single‑stage
BB5 – between‑bearing, barrel type, multi‑stage high pressure
VS6 – vertical suspended, double‑casing
We also offer complete Sulzer series replacements, including:
Sulzer BBS (BB2 equivalent)
Sulzer OHH (OH2 equivalent)
Sulzer GSG (multistage ring section)
Sulzer ZE (heavy‑duty process pump)
For inquiries, technical support, sizing, or a quotation, please contact us:
info@hyrig.com
HYRIG – Reliable, grid‑ready, and code‑compliant pumping solutions for Iran’s oil, gas, and petrochemical industry.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.