TEDA KHT5500 hydraulic power tong mandatory safety rules. Operator: read manual, pass training, wear PPE (coverall, steel-toe boots, helmet, goggles, gloves). Operation side only – no standing at jaw opening. Safety door must be closed before operation – door interlock cuts power if opened. No overpressure (rated 14MPa / 2000 PSI). No gear shifting while motor running. High torque (>20400 N·m / 15000 ft·lb): verify intermediate gears fully meshed. Installation: suspension pulley ≥5 ton, wire rope ≥1/2″, tail rope ≥5/8″ horizontal. Level tong before use. Maintenance: depressurize before disassembly, check jaw wear, inspect ropes. Emergency: stop if slipping, torque drop, leaks, noise. Contact info@hyrig.com.

Conatct For Details
DetailReview(0)Additional

Section IV: Special Safety Specifications (Core Mandatory Requirements)


1. Operator Qualification & Safety Standards

Qualification Requirements:

  • Must read and fully understand the operation & maintenance manual

  • Master the hydraulic directional valve and shift lever logic

  • Pass special training and assessment before operating

Personal Protective Equipment (PPE):

  • Work coverall

  • Impact-resistant steel-toe safety boots

  • Hard hat

  • Impact-resistant safety goggles

  • Oil-resistant protective gloves

  • Prohibited: Loose clothing or jewelry

Operating Position:

  • Strictly operate from the designated operation side of the equipment

  • Prohibited: Standing or staying at the jaw opening area or hydraulic hose connections


2. Operational Safety Controls

Safety Door Interlock Rule:

  • Safety door must be closed before make-up/break-out – otherwise hydraulic system locks and equipment cannot start

  • Never open the safety door during operation – opening automatically cuts hydraulic power to prevent pinching injuries

Area Safety Management:

  • No tools or debris within the equipment working radius

  • No unauthorized personnel in the area

  • Ensure tail rope is securely fixed – no one steps over or approaches it

Prohibited Actions:

  • No overpressure or over-torque – rated system pressure 14 MPa (2000 PSI). Exceeding can cause structural damage or pipe failure.

  • No gear shifting while hydraulic motor is running – must stop before shifting.

  • No hands or tools near jaw gripping area or gear meshing zone – even when equipment is stopped, confirm pressure is relieved before approaching.

High Torque Operation Protection:

  • When operating torque exceeds 15,000 ft·lb (20,400 N·m) , verify that both intermediate gears are fully meshed with the large opening gear to prevent gear disengagement.


3. Installation & Commissioning Safety

Suspension & Fixing:

  • Use pulley with rated load ≥5 tons

  • Wire rope diameter ≥1/2″

  • After suspension, repeatedly check anchor point strength – no looseness

  • Tail rope diameter ≥5/8″ , fixed horizontally to rig floor or derrick, perpendicular to tong centerline

Leveling Requirement:

  • Complete both front/rear and crosswise leveling after installation

  • Prohibited to operate without leveling – jaw slipping may cause pipe drop

Hose Connection:

  • Pressure hose (NPT 1″) and return hose (NPT 1 1/4″) – pressure test after connection to confirm no leaks

  • Set hydraulic power unit relief valve to 14 MPa (2000 PSI), then lock pressure adjustment handle


4. Maintenance & Repair Safety

Depressurization Procedure Before Disassembly:

  • Before removing jaws, tooth seats, or molds:

    • Turn off hydraulic power source

    • Release system pressure

    • Confirm torque gauge reads zero

Wear Parts Inspection:

  • Before each operation, check jaw wear condition

  • Check safety door gap (adjust via eccentric shaft to minimum without affecting door operation)

  • If gap is excessive, stop immediately and adjust – prevents equipment damage or safety failure

Rope Safety:

  • Regularly inspect lifting rope and tail rope for wear, corrosion, broken strands, or deformation

  • Replace immediately if any defect found – do not use damaged ropes

Storage Safety:

  • When idle, keep away from rig floor

  • Apply grease on exposed jaw surfaces for rust prevention

  • Store in clean, dry environment

  • For long-distance transport, seal oil ports to prevent debris ingress


5. Emergency Safety Response

Equipment Anomalies:

  • If jaw slipping, sudden torque drop, or hose leak occurs during operation:

    • Immediately stop operation

    • Close hydraulic power unit

    • Investigate fault (refer to troubleshooting section)

    • Prohibited to force operation

Personnel Protection:

  • For hydraulic oil leaks: wear chemical-resistant gloves for cleanup – avoid skin contact

  • For unusual noise or abnormal vibration: stop immediately, check gear meshing, bearings, etc.

Emergency Stop:

  • In unexpected situations:

    • Directly shut off main switch of hydraulic power unit, or

    • Open safety door to trigger interlock shutdown

  • Ensures personnel and equipment safety


Safety Statement

All safety specifications for this equipment are based on oilfield operation safety standards. Operators must strictly follow them. Violation of these rules may result in equipment damage, serious injury, or death. TEDA assumes no liability for losses caused by improper or non-compliant operation.


Contact Us

For safety training, compliance questions, or to request the full operation & maintenance manual, please contact us:

info@hyrig.com

We provide comprehensive safety support and genuine parts for all TEDA power tongs, including the KHT5500.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit