Correct installation of the Lower IBOP 114706-500 on a VARCO TDS-8SA top drive ensures reliable secondary well control.
Order from top drive down:
Top drive spindle
Upper IBOP 110103-500
Lower IBOP 114706-500 (this product)
Saver sub (optional)
Drill pipe
Inspect the IBOP – Check for shipping damage, clean all surfaces.
Verify threads – Confirm top and bottom connections match adjacent components.
Check seal condition – Ensure NBR seals are not cracked or hardened.
Prepare thread compound – Use API 7-1 approved thread lubricant.
| Step | Action |
|---|---|
| 1 | Apply thread compound to both the Lower IBOP top threads and mating connection (upper IBOP bottom). |
| 2 | Hand-thread the Lower IBOP onto the upper IBOP until finger tight. |
| 3 | Use a torque wrench to tighten to 13,500 – 15,000 N·m (10,000 – 11,000 ft·lbs). |
| 4 | Attach the T-handle and verify smooth operation. |
| 5 | Connect the bottom string (saver sub or drill pipe) to the lower IBOP bottom thread (use same compound). |
Per API 16D, test the lower IBOP both independently and as part of the assembly:
Close lower IBOP, open upper IBOP. Apply 500 psi from below. Hold 5 minutes. No visible leakage.
Close lower IBOP, open upper IBOP. Apply 5,000 psi from below. Hold 5 minutes. No pressure drop.
Both IBOPs closed – test lower IBOP seal while upper IBOP is open.
Both IBOPs open – perform shell test on lower IBOP (7,500 psi).
| Interval | Action |
|---|---|
| Daily / each tour | Cycle the valve fully open and closed. Check for smooth operation. |
| Weekly | Visual inspection for damage or corrosion. |
| Per API 16D (14 days) | Pressure test (low and high). Record results. |
| After 300 cycles or 6 months | Replace seals (repair kit). Inspect ball and seats. |
| After a well control event | Disassemble, inspect, replace seals regardless of cycle count. |
The 114706-500 uses a standard NBR seal kit. Replacement procedure is similar to upper IBOP.
Repair kit part number: Contact info@hyrig.com for kit details.
| Problem | Possible Cause | Solution |
|---|---|---|
| Hard to turn | Mud residue inside | Flush with clean fluid, lubricate |
| Hard to turn | Differential pressure too high | Equalize pressure across valve |
| Leaks when closed | Worn seat or ball | Replace seals, inspect ball |
| Thread galling | Insufficient thread compound | Clean threads, reapply compound |
| Cannot close fully | Debris in ball cavity | Remove IBOP, disassemble and clean |
Always equalize pressure across the lower IBOP before operating it.
Use proper lifting equipment – IBOP weight approx. 50 kg (110 lbs).
Never use the lower IBOP as a choke – only fully open or fully closed.
For repair kits, special tools, or field service assistance:
Email: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.