MEG Pump | API 610 OH2 Centrifugal Pump | China OH2 Pump Manufacturer

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 OH2 single‑stage, overhung pump for MEG (monoethylene glycol) service. Handles glycol at temperatures up to 150°C, corrosion resistant stainless steel construction. Suitable for gas dehydration, hydrate suppression, and heat transfer loops. China OH2 pump manufacturer.

Conatct For Details
DetailReview(0)Additional

A MEG pump circulates monoethylene glycol (MEG) in gas processing, petrochemical, and industrial applications. Common services include natural gas dehydration (glycol absorption), hydrate inhibition (injection into pipelines), and heat transfer loops. MEG is moderately corrosive, has low viscosity, and can operate at temperatures from ambient to 150°C. Our API 610 OH2 centrifugal pump is specifically engineered for reliable, long‑life MEG circulation duty. This design fully complies with API 610 11th/12th edition (ISO 13709) .

Structure match check: API 610 OH2 is defined as a horizontal, single‑stage, overhung pump with foot‑mounted casing and back pull‑out design. This matches MEG requirements because:

  • OH2 provides easy maintenance – back pull‑out for seal, impeller, bearing inspection without disturbing piping – important for continuous gas plant operation.

  • Corrosion resistant materials (316SS, duplex) are standard for glycol contact.

  • High temperature capability (up to 150°C) is accommodated with proper seal plans and optional bearing cooling.

  • Low NPSH – MEG reboilers or flash drums may have limited NPSHa. Inducer option available.

Why API 610 OH2 for MEG duty?

  • Corrosion resistance – MEG degrades over time to acidic byproducts (glycolic, formic acid). Wetted parts in 316SS minimum; duplex or Alloy 20 for higher temperature or more corrosive service.

  • High temperature capability – Lean MEG leaving the reboiler can be 120-150°C. Centerline support optional for higher temperatures; bearing housing cooling recommended above 120°C.

  • Low NPSH capability – Rich MEG from flash drum or absorber often has low NPSHa. Optional inducer reduces NPSHr below 1 m, preventing cavitation and erosion.

  • Good sealing – API 682 Plan 11 (internal recirculation) for clean MEG; Plan 23 (cooled recirculation) for hot MEG; Plan 52/53A double seals if zero emissions required (glycol is not highly toxic but may be regulated).

  • High efficiency – MEG pumps often run continuously. Hydraulic optimization reduces energy cost.

  • Wide flow range – 5 to 2000 m³/h, head up to 250 m, covering gas plant circulation and pipeline injection.

Key design features for MEG service

  • Materials – Casing: 316SS (CF8M, CF3M) or duplex. Impeller: 316SS, 17-4PH, or duplex. Shaft: 316SS or duplex. Wear rings: 17-4PH or Stellite. Gaskets: PTFE or spiral wound with PTFE.

  • Temperature handling – For MEG above 120°C, specify centerline support (not foot‑mounted). Bearing housing cooling fan or water jacket. Mechanical seal with Plan 23 (cooled recirculation).

  • Inducer – Recommended if NPSHa is less than 3 m, especially for rich MEG from flash drum.

  • Impeller – Closed, radially balanced, trimmed to duty point. For larger flows, double‑suction option available to reduce NPSHr and balance thrust.

  • Sealing – Cartridge mechanical seals. Standard Plan 11 (internal recirculation). For hot MEG (>120°C): Plan 23. For dirty MEG (with particulates): Plan 31 (cyclone separator) or Plan 32 (external clean flush). For zero emissions: Plan 52/53A double seals.

  • Bearings – Anti‑friction, oil bath or oil mist. For continuous service, optional vibration and temperature probes.

  • Vent and drain – Full ports for complete draining – important to prevent glycol freezing in cold climates during shutdown.

Typical performance range

ParameterValue
Flow rate5 – 2000 m³/h
HeadUp to 250 m
Temperature-20°C to +150°C
Pressure ratingUp to 25 bar
NPSHr (with inducer)As low as 0.5 m
Speeds1450 / 2900 / 3600 rpm
ViscosityLow (MEG ~20 cSt at 20°C, lower when hot)

Typical applications

  • Lean MEG circulation – From reboiler to absorber (gas dehydration).

  • Rich MEG transfer – From absorber/flash drum to reboiler or to regeneration.

  • MEG injection pumps – For hydrate suppression in gas pipelines (high pressure, low flow).

  • Heat transfer medium circulation – MEG as coolant/heating fluid.

  • Offshore gas platform glycol loops – Corrosion resistant materials required.

Why choose our API 610 OH2 MEG pump?

  • Full API 610 compliance – Performance test, NPSH test (inducer), mechanical run test included.

  • Corrosion resistant – 316SS standard; duplex or Alloy 20 for severe service.

  • High temperature capability – Centerline support, cooled bearings, Plan 23 seals for hot MEG.

  • Low NPSH – Inducer prevents cavitation, ensures stable operation from flash drums.

  • Short lead time – Standard 316SS pumps ex‑stock; custom inducer / high temp options 8-10 weeks.

  • Global spare parts support – Impellers, seals, wear rings, shafts, casings shipped worldwide.

Quality assurance

  • ISO 9001:2015 certified.

  • API 610 mechanical run test (4 hours minimum) with vibration and bearing temperature monitoring.

  • NPSH test verification (if inducer ordered).

  • Hydrostatic test of casing.

  • Material traceability EN 10204 3.1 / 3.2.

  • PMI (positive material identification) for alloy components.

  • NDE – MT, PT, UT as required.

How to specify your MEG pump

Please provide: flow (m³/h), head (m), operating temperature (°C), NPSHa (m), MEG concentration (%, or lean/rich), presence of solids (corrosion products), required material (316SS / duplex / Alloy 20), and any emission regulations. We will recommend inducer (yes/no), impeller size, seal plan (11/23/31/32), bearing cooling (yes/no), and driver details.

Contact us

For a quotation or technical discussion on MEG pumps (API 610 OH2) :

info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit