HYRIG can supply the non-magnetic drill collar range and its spare parts. The non-magnetic drill collar is a low-permeability BHA component used to isolate MWD/LWD magnetic interference and maintain survey accuracy in directional drilling. It is manufactured from low-carbon stainless steel and meets API Spec 7-1 and SY/T5144 requirements.
Conatct For Details
DetailReview(0)Additional

Key Facts

  • Outer diameter range: 79.4 mm (3-1/8") to 279.4 mm (11")
  • Inner diameter range: 31.8 mm to 76.2 mm
  • Connection range: NC23 to NC77, plus 6-5/8 REG and 7-5/8 REG
  • Magnetic permeability: μr < 1.010; average below 1.010
  • Magnetic field gradient: ΔB ≤ 0.05 μT
  • Minimum yield strength: 689–827 MPa (depending on OD range)
  • Hardness: 285–341 HB
  • Standard: API Spec 7-1, SY/T5144

Key Specifications — Non-Magnetic Drill Collar Dimensions & Mechanical Properties

Dimensions (Selected sizes, full range from 79.4 mm to 279.4 mm OD)

ConnectionOD mmID mmLength mmShoulder Diameter D_F mmBending Strength Ratio
NC23-3179.431.8914076.22.57:1
NC26-3588.938.1914084.52.42:1
NC31-41104.850.89140 / 9450104.42.43:1
NC38-50127.057.29140 / 9450121.02.38:1
NC46-62158.871.49140 / 9450150.02.63:1
NC50-70177.871.49140 / 9450164.72.73:1
NC56-80203.271.49140 / 9450190.13.02:1
NC61-90228.671.49140 / 9450212.73.17:1
NC70-100254.076.29140 / 9450237.32.81:1
7-5/8 REG241.376.29140 / 9450223.82.81:1

Mechanical Properties

OD Range mmMin Yield Strength MPaMin Tensile Strength MPaMin Elongation %Min Impact Energy J
70–98.48278961681
101.6–174.67588271881
177.8–279.46897582081

Data source: Technical data table.

Dimensions

The dimensions listed above are finished machining dimensions. When confirming fit, ensure the outer diameter clears the hole size and the inner diameter accepts the MWD/LWD tool. The magnetic permeability is controlled through material chemistry and heat treatment. For sizes above 241.3 mm, the OD tolerance is +6.4 mm unless otherwise agreed.

Structure / Working Principle

The non-magnetic drill collar is positioned directly above the bit or within the BHA to isolate magnetic survey instruments from the steel drill string. The low-carbon stainless steel body provides low magnetic permeability, while the thick wall supplies weight on bit and BHA stiffness. In directional drilling, standard steel collars distort azimuth readings; a non-magnetic collar keeps the magnetic reference stable, reducing correction runs.

Cross-Reference & Replacement

Replacing an existing non-magnetic drill collar? Check these points before matching:

  1. Connection type: NC23 to NC77, or REG. Confirm pin/box combination against your BHA.
  2. OD and ID: OD must clear the hole; ID must accept the MWD/LWD tool.
  3. Magnetic certificate: Request μr and ΔB values, not just "non-magnetic" wording.
  4. Thread treatment: Cold rolled, copperized, or phosphated. Match existing string practice.

For standard alloy steel collars, explore the Drill Collar page. For reduced wall contact in deviated wells, see the Spiral Drill Collar page.

Applications

  • Directional and horizontal drilling where MWD/LWD survey accuracy is required.
  • Geothermal and geological exploration wells requiring non-magnetic BHA components.
  • Extended-reach and complex wellpaths where magnetic interference must be minimized.
  • BHA weight and stiffness applications requiring a thick-wall collar without magnetic distortion.

Selection Support

Not sure which OD/ID/connection combination matches your BHA? Send the hole size, MWD/LWD tool OD, adjacent connection type, and required length, and our engineers will match the collar size and thread.

Frequently Asked Questions

Q: What is the magnetic permeability of this non-magnetic drill collar?
A: μr is < 1.010, with an average below 1.010; magnetic field gradient ΔB is ≤ 0.05 μT.

Q: What is the difference between this non-magnetic drill collar and a standard drill collar?
A: The non-magnetic collar uses low-carbon stainless steel for magnetic isolation; a standard collar uses AISI 4145H alloy steel for weight and stiffness.

Q: Can the threads be cold rolled or double-shouldered?
A: Yes. Threads can be cold rolled, copperized, or phosphated; double-shoulder and special threads are available.

Q: How do I confirm the right size for my BHA?
A: Match connection type, OD clearance to hole size, ID clearance to MWD/LWD tool OD, and required length.

Q: Are material and NDT certificates available?
A: Yes. Material traceability and NDT records can be provided; request them at the inquiry stage.

Please follow standard industrial safety procedures during installation and maintenance.

Contact

For non-magnetic drill collar selection and spare parts, contact HYRIG: info@hyrig.com

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit