Dimensions (Selected sizes, full range from 79.4 mm to 279.4 mm OD)
| Connection | OD mm | ID mm | Length mm | Shoulder Diameter D_F mm | Bending Strength Ratio |
|---|---|---|---|---|---|
| NC23-31 | 79.4 | 31.8 | 9140 | 76.2 | 2.57:1 |
| NC26-35 | 88.9 | 38.1 | 9140 | 84.5 | 2.42:1 |
| NC31-41 | 104.8 | 50.8 | 9140 / 9450 | 104.4 | 2.43:1 |
| NC38-50 | 127.0 | 57.2 | 9140 / 9450 | 121.0 | 2.38:1 |
| NC46-62 | 158.8 | 71.4 | 9140 / 9450 | 150.0 | 2.63:1 |
| NC50-70 | 177.8 | 71.4 | 9140 / 9450 | 164.7 | 2.73:1 |
| NC56-80 | 203.2 | 71.4 | 9140 / 9450 | 190.1 | 3.02:1 |
| NC61-90 | 228.6 | 71.4 | 9140 / 9450 | 212.7 | 3.17:1 |
| NC70-100 | 254.0 | 76.2 | 9140 / 9450 | 237.3 | 2.81:1 |
| 7-5/8 REG | 241.3 | 76.2 | 9140 / 9450 | 223.8 | 2.81:1 |
Mechanical Properties
| OD Range mm | Min Yield Strength MPa | Min Tensile Strength MPa | Min Elongation % | Min Impact Energy J |
|---|---|---|---|---|
| 70–98.4 | 827 | 896 | 16 | 81 |
| 101.6–174.6 | 758 | 827 | 18 | 81 |
| 177.8–279.4 | 689 | 758 | 20 | 81 |
Data source: Technical data table.
The dimensions listed above are finished machining dimensions. When confirming fit, ensure the outer diameter clears the hole size and the inner diameter accepts the MWD/LWD tool. The magnetic permeability is controlled through material chemistry and heat treatment. For sizes above 241.3 mm, the OD tolerance is +6.4 mm unless otherwise agreed.
The non-magnetic drill collar is positioned directly above the bit or within the BHA to isolate magnetic survey instruments from the steel drill string. The low-carbon stainless steel body provides low magnetic permeability, while the thick wall supplies weight on bit and BHA stiffness. In directional drilling, standard steel collars distort azimuth readings; a non-magnetic collar keeps the magnetic reference stable, reducing correction runs.
Replacing an existing non-magnetic drill collar? Check these points before matching:
For standard alloy steel collars, explore the Drill Collar page. For reduced wall contact in deviated wells, see the Spiral Drill Collar page.
Not sure which OD/ID/connection combination matches your BHA? Send the hole size, MWD/LWD tool OD, adjacent connection type, and required length, and our engineers will match the collar size and thread.
Q: What is the magnetic permeability of this non-magnetic drill collar?
A: μr is < 1.010, with an average below 1.010; magnetic field gradient ΔB is ≤ 0.05 μT.
Q: What is the difference between this non-magnetic drill collar and a standard drill collar?
A: The non-magnetic collar uses low-carbon stainless steel for magnetic isolation; a standard collar uses AISI 4145H alloy steel for weight and stiffness.
Q: Can the threads be cold rolled or double-shouldered?
A: Yes. Threads can be cold rolled, copperized, or phosphated; double-shoulder and special threads are available.
Q: How do I confirm the right size for my BHA?
A: Match connection type, OD clearance to hole size, ID clearance to MWD/LWD tool OD, and required length.
Q: Are material and NDT certificates available?
A: Yes. Material traceability and NDT records can be provided; request them at the inquiry stage.
Please follow standard industrial safety procedures during installation and maintenance.