HYRIG can supply PARKER D41VW and D81VW pilot-operated directional valves. Understanding the model code is essential for selecting the correct spool type, spool position, and electrical/pilot option.
| Position | Code | Meaning | Options |
|---|---|---|---|
| 1 | D41VW / D81VW | Series & Size | D41VW = NG16; D81VW = NG25 |
| 2 | 001 / 002 / 020 / 026 / 030 etc. | Spool type | Determines flow paths in each position |
| 3 | B / C / H / D | Spool position | Solenoid configuration and spring/detent behaviour |
| 4 | 1 / 2 / 3 / 4 | Pilot supply / drain | Internal/External pilot and drain combinations |
| 5 | N / - | Seal material | N = NBR (standard); omit = NBR standard |
| 6 | J / K / U / G | Voltage | J = 24V DC; K = 12V DC; U = 98V DC; G = 205V DC |
| 7 | W / A / Y etc. | Electrical connection | W = connector EN 175301-803; A/Y = other connector types |
D41VW and D81VW require a minimum pilot pressure (typically 5.1 bar, or 6.9 bar for spool 002/007/008/009/014). Pilot supply and drain can be configured as internal or external, specified by code positions in the full model number.
Need help decoding your existing nameplate or selecting a replacement? Contact HYRIG with your full model code or a photo of the nameplate, and our engineers will confirm the correct configuration. For a ready reference, view PARKER D81VW030B Directional Valve.
Browse the complete series pages for available spool and voltage combinations: PARKER D41VW Directional Valve Series and PARKER D81VW Directional Valve Series.
Disclaimer: PARKER is a registered trademark of Parker Hannifin Corporation. HYRIG is an independent supplier of hydraulic components and is not affiliated with Parker Hannifin Corporation.
For help with PARKER D41VW/D81VW model codes, contact HYRIG: info@hyrig.com