A pressure booster system (also called an automatic water pressure pump set or domestic booster set) is a complete, ready‑to‑install unit that automatically increases and stabilises low or fluctuating water pressure for homes, apartments, small commercial buildings, and irrigation systems. Unlike a standalone pump that requires manual switching, this integrated system includes a self‑priming centrifugal pump, a small pre‑charged pressure tank, a pressure switch, and a pressure gauge – all mounted on a compact baseplate and pre‑wired.
The system senses when a tap is opened, starts the pump automatically, and stops it when the tap is closed. The pressure tank prevents rapid cycling (short‑cycling) and provides a small reserve of pressurised water for immediate use. The result is consistent water pressure, reduced wear on the pump, and no need for user intervention.
This system is ideal for:
Homes with low mains water pressure
Water supply from rainwater tanks or storage cisterns
Shallow wells (up to 8 m suction lift)
Small apartments, offices, or shops needing pressure boosting
Garden irrigation and greenhouse watering
The system consists of four core components:
Self‑priming centrifugal pump – Draws water from the source (tank, well, or mains) and pressurises it.
Pressure switch – Senses discharge pressure. Factory set to cut in at 1.5 bar (22 psi) and cut out at 3 bar (43 psi) – adjustable within a range of 1–5 bar.
Small diaphragm pressure tank (2–8 litres) – Cushions pressure spikes, absorbs water hammer, and prevents the pump from starting/stopping too frequently when small amounts of water are used.
Pressure gauge – Allows visual confirmation of system performance.
Operating cycle:
With all taps closed, the pump maintains the cut‑out pressure (e.g., 3 bar) and the tank holds pressurised water.
When a tap is opened, pressure drops to the cut‑in setting (e.g., 1.5 bar); the pressure switch starts the pump.
The pump runs, supplying water while the desired flow is needed.
When the tap closes, pressure builds back to cut‑out; the pump stops.
The small tank provides instant water for a few seconds, preventing the pump from starting for every small demand (e.g., filling a glass). This reduces energy consumption and prolongs motor life.
| Parameter | Range |
|---|---|
| Maximum flow | 3 – 8 m³/h (50 – 135 L/min) |
| Maximum pressure (head) | 4 – 6 bar (40 – 60 m) – factory set 3 bar cut‑out |
| Suction lift | Up to 8 m (vertical lift from water surface) |
| Motor power | 0.5 – 1.5 HP (0.37 – 1.1 kW) |
| Voltage / frequency | 220‑240V / 50Hz or 110‑120V / 60Hz (single‑phase) |
| Inlet / outlet size | 1″ × 1″ or 1.25″ × 1″ (25mm or 32mm) |
| Pressure tank volume | 2 – 8 litres (pre‑charged diaphragm type) |
| Pressure switch range | 1 – 5 bar (factory set 1.5‑3.0 bar) |
| Liquid temperature | 0 – 40°C |
| Enclosure protection | IP44 – IP54 (motor) , IPX2 (control box) |
| Self‑priming time | ≤60 seconds (at 5 m lift) |
| Noise level | ≤65 dB(A) at 1 metre |
| Component | Standard Material | Upgrade Option |
|---|---|---|
| Pump casing | Cast iron with epoxy coating | Stainless steel 304 |
| Impeller | Brass / engineered plastic | Stainless steel 304 |
| Diffuser / ejector | Brass / engineered plastic | Stainless steel |
| Pressure tank | Steel with epoxy coating, butyl diaphragm | Stainless steel (for drinking water) |
| Shaft | Stainless steel (AISI 304) | AISI 316 |
| Mechanical seal | Carbon / ceramic / NBR | Silicon carbide / Viton |
| Fasteners | Zinc‑plated steel | Stainless steel |
For potable water, all wetted parts are compliant with local drinking water regulations (WRAS, NSF/ANSI 61 available on request).
| Feature | Benefit |
|---|---|
| Automatic start/stop | No manual switching; water on demand |
| Dry‑run protection (built‑in pressure switch) | Pump stops if suction water is lost (pressure falls below 1 bar) |
| Thermal overload protection | Motor automatically shuts off if overheated; auto‑reset type |
| Built‑in check valve | Prevents backflow when pump stops; keeps system pressurised |
| Large filter strainer | Protects pump from debris (foot valve or suction strainer) |
| Easy priming port | Transparent plug for quick fill and visual check |
| Corrosion‑resistant coating | Epoxy‑painted casting for outdoor or damp locations |
| Low noise operation | Rubber feet and optimised hydraulics reduce vibration |
| Pressure gauge | Shows system pressure at a glance |
| Application | Description |
|---|---|
| Household water pressure boosting | Increase low mains pressure to operate showers, washing machines, and multiple taps simultaneously |
| Rainwater tank supply | Pump rainwater from below‑grade or above‑ground tank to garden, toilet, or laundry |
| Shallow well supply | Draw from wells up to 8 m deep for domestic use in rural areas |
| Small apartment / building | Boost pressure for 2–3 storey buildings with insufficient mains |
| Garden irrigation | Run sprinklers, drip systems, or hose reels effectively |
| Car wash / workshop | Provide pressurised water for cleaning equipment |
| Rooftop tank filling | Move water from ground tank to overhead tank |
Site selection – Place the system on a solid, level, dry surface, protected from rain and direct sun. Ensure adequate ventilation around the motor.
Suction piping – Use rigid pipe (PVC or metal) of at least the pump inlet diameter. Keep the suction pipe short, with minimal elbows. Slope slightly upward to the pump. For well/tank suction, install a foot valve with strainer at the water source.
Discharge piping – Connect to the house or garden distribution system. Install an isolation valve and check valve (if not built‑in).
Electrical connection – Connect to a dedicated circuit with RCD/GFCI protection. Use a weatherproof socket if outdoors. The pump is supplied with a power cord (1–2 m) – extension cables must be of adequate gauge.
Priming – Remove priming plug, fill the pump casing and suction piping completely with water, then replace the plug. Never run the pump dry – even a few seconds will damage the mechanical seal.
Start‑up – Open a tap, plug in the pump. It will prime within 60 seconds and deliver water. If no water after 2 minutes, stop, check suction line for air leaks, and re‑prime.
The pressure switch is factory set to cut in at 1.5 bar and cut out at 3.0 bar – suitable for most homes. To adjust:
Increase cut‑in AND cut‑out together – Turn the large nut clockwise.
Decrease cut‑in AND cut‑out together – Turn the large nut anticlockwise.
Widen differential (increase cut‑out only) – Turn the small nut clockwise (increase cut‑out).
Narrow differential (decrease cut‑out only) – Turn the small nut anticlockwise.
Do not set cut‑out above the pump’s maximum pressure rating (stamped on the nameplate). For systems with more than 3–4 fixtures, consider adding a larger external pressure tank.
A pressure booster system with a pressure switch runs only when water is demanded – unlike a continuously running pump. However, the pump operates at full speed whenever it is on. For applications with highly variable flow (e.g., large homes or commercial buildings), a variable frequency drive (VFD) system is more efficient. For most single‑family homes and small buildings, the simple on/off pressure switch system is cost‑effective and reliable.
| Task | Frequency | Instructions |
|---|---|---|
| Check pressure tank air charge | Every 6 months | With pump off and pressure zero, use a tyre gauge on tank valve. Pre‑charge should be 0.2 bar below cut‑in pressure (e.g., 1.3 bar for 1.5 bar cut‑in). Pump air if needed. |
| Clean suction strainer / foot valve | 6‑12 months | Remove debris from mesh or strainer. |
| Inspect for leaks (shaft seal, pipe joints) | Monthly | Look for drips; replace seal if leaking. |
| Winterisation (freezing areas) | Before freeze | Drain pump, tank, and piping completely; store indoors or apply heat trace. |
| Check pressure switch contacts | Annually | Clean or replace if corroded / pitted. |
If the pump cycles rapidly (on/off every few seconds), the pressure tank is likely waterlogged (lost air charge). Re‑pressurise the tank as above; if it fails to hold pressure, the diaphragm is damaged and the tank must be replaced.
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump does not start | No power, pressure switch stuck, thermal trip | Check outlet, breaker, plug; press reset button on motor; tap pressure switch |
| Pump runs but no water | Loss of prime, air leak on suction, foot valve stuck | Re‑prime; check suction joints with soapy water; clean foot valve |
| Pump cycles on/off rapidly | Waterlogged pressure tank, system leak, faulty switch | Re‑pressurise tank; repair leaks; replace switch |
| Low pressure (pump runs continuously) | Clogged impeller or strainer, worn pump, low water supply | Clean impeller; check suction pipe; verify well/tank level |
| Motor hums but does not run | Stuck impeller, bad start capacitor (single‑phase) | Turn off power, clear debris from impeller; replace capacitor |
| Noisy operation | Cavitation (restricted suction), loose base, worn bearings | Check suction pipe size; tighten mounting; replace pump if bearings worn |
Plug‑and‑play – Fully assembled, pre‑wired, includes tank and switch – ready to connect to water and power.
Automatic convenience – No manual operation; system starts and stops with water demand.
Stable pressure – Pressure tank and switch provide consistent supply without severe fluctuations.
Self‑priming – Draws water from 8 m below; no foot valve needed (though recommended).
Corrosion‑resistant – Epoxy‑coated cast iron or full stainless steel options.
Compact design – Fits under a sink, in a utility room, or beside a rainwater tank.
Safety built in – Thermal protection, dry‑run shutdown via low‑pressure cut‑off, IP44 motor.
Energy efficient – Only runs when water is used; no idle power consumption.
Low maintenance – Simple, proven technology with widely available spare parts.
2‑year warranty – Backed by responsive customer support.
| Component | Recommended Quantity |
|---|---|
| Mechanical seal kit | 1 set |
| Pressure switch (same range) | 1 |
| Pressure tank (2–8 L) | 1 (for eventual replacement) |
| Foot valve with strainer (1″ or 1.25″) | 1 |
| Start capacitor (for single‑phase motor) | 1 |