A solar pumping system uses electrical energy generated by photovoltaic (PV) panels to power a water pump, without connection to the electricity grid or a diesel generator. It is an autonomous, clean, and low‑operating‑cost solution for water extraction in remote areas where grid power is unavailable, unreliable, or expensive to install.
The system typically consists of:
Solar PV array – Panels mounted on a ground or roof structure, sized to match the pump’s power requirement.
Pump – Submersible (borehole) or surface (centrifugal, helical, or diaphragm) depending on water source depth and type.
Controller / VFD (Variable Frequency Drive) – Converts DC from panels to AC for AC pumps (or directly drives DC pumps), optimises power extraction (MPPT – Maximum Power Point Tracking), and provides protection (dry run, overvoltage, undervoltage).
Optional sensors and accessories – Water level sensors, flow meters, remote monitoring (GSM/IoT), and storage tanks.
Solar pumping systems are widely used for:
Agricultural irrigation (drip, sprinkler, flood)
Livestock watering (cattle, sheep, horses)
Rural and village domestic water supply
Remote mining and construction dewatering
Pond aeration and fountain circulation
Wildlife reserves and remote cabins
| Configuration | Pump Type | Best Application | Advantages |
|---|---|---|---|
| DC direct drive | DC submersible or surface pump | Small to medium flow (≤10 m³/h), low to medium head (≤100 m) | Simple, cost‑effective, no inverter loss, lower upfront cost |
| AC with VFD | AC submersible or surface pump (standard 3‑phase) | Larger flows (10‑500 m³/h), higher heads (up to 400 m), long pipe runs | Uses standard AC pumps (easier replacement), flexible, higher efficiency at partial loads |
| Hybrid (Solar + Grid / Generator) | AC pump with dual power input | Critical water supply requiring 24/7 operation | Seamless switching; works with solar, grid, or diesel backup |
| Parameter | Small DC System | Medium AC System | Large AC / High Flow System |
|---|---|---|---|
| Flow range | 0.5 – 10 m³/h | 5 – 100 m³/h | 50 – 500 m³/h |
| Head range | 5 – 100 m | 10 – 200 m | 20 – 400 m |
| Solar array power | 0.3 – 5 kWp | 5 – 30 kWp | 30 – 150 kWp (multiple arrays) |
| Pump power | 0.2 – 4 kW | 4 – 22 kW | 22 – 110 kW |
| Voltage (DC side) | 24V – 220V DC | 300V – 800V DC (string input) | 300V – 1000V DC |
| Voltage (AC pump) | N/A | 3‑phase 230V/400V/690V | 3‑phase 400V/690V |
| Pump type | Helical rotor or centrifugal submersible | Submersible multistage or surface centrifugal | Submersible multistage (borehole) or end‑suction |
| Maximum submersion (submersible) | 50 m | 200 m | 350 m |
| Controller type | MPPT DC drive | VFD with MPPT + AC output | Multiple VFDs or central inverter |
| Pipe connection | 1″ – 2″ | 2″ – 6″ | 6″ – 12″ |
1. Solar PV Array
Panels: Monocrystalline or polycrystalline (mono recommended for higher efficiency in limited space)
Mounting: Ground (fixed tilt) or single‑axis tracking (for larger systems)
Protection: Fuses, surge arrestors, DC isolators
2. Pump Unit
| Source Type | Recommended Pump | Notes |
|---|---|---|
| Borehole (deep well) | Submersible multistage centrifugal | AISI 304/316 stainless steel, floating impellers, sand‑tolerant |
| Open well (suction lift ≤8m) | Self‑priming surface centrifugal or jet pump | Cast iron or stainless steel, high suction lift capability |
| River / pond / reservoir (flooded suction) | Horizontal end‑suction centrifugal or submersible | High flow, low head |
| Shallow well (depth ≤20m) | Helical rotor pump | Excellent low‑speed efficiency, handles slightly dirty water |
3. Controller – The “Brain” of the System
MPPT (Maximum Power Point Tracking) – Continuously adjusts pump speed to draw maximum available power from the solar array as sunlight changes.
VFD (for AC pumps) – Converts DC to AC and controls pump speed, providing soft start and variable flow.
Protection features:
Dry‑run protection (stops pump if water level falls below intake)
Overvoltage / undervoltage shutdown
Overcurrent / overload protection
Lightning protection (surge arrestors recommended)
Optional features:
Float switch / level sensor input (for tank full/empty)
Remote monitoring (2G/4G, Wi-Fi, or RS485/Modbus)
Data logging (flow, pressure, power, runtime)
4. Piping & Accessories
Rising main (for borehole): galvanised steel or HDPE pipe with appropriate pressure rating
Discharge pipe: HDPE, PVC, or steel
Check valve (non‑return) at pump outlet
Gate valve or butterfly valve for isolation
Pressure gauge (for surface systems)
Water level sensors (for borehole and tank)
Water tank (optional – concrete, steel, or plastic) for water storage
For borehole submersible pumps in solar systems (continuous start/stop as sunlight varies), material selection is critical:
| Component | Standard (DC / small AC) | Premium (Large AC / aggressive water) |
|---|---|---|
| Pump casing | AISI 304 stainless steel | AISI 316 or duplex |
| Impellers | Thermoplastic (Noryl) or AISI 304 | AISI 316 / duplex |
| Diffusers | Thermoplastic or stainless steel | Stainless steel |
| Shaft | AISI 420 / 431 stainless steel | AISI 316 / duplex |
| Motor housing | AISI 304 stainless steel | AISI 316 |
| Mechanical seals | Silicon carbide vs. silicon carbide | Silicon carbide / tungsten carbide |
| Fasteners | Stainless steel | Duplex |
Floating impeller design (standard on most quality submersibles) is essential for solar operation because the pump starts and stops many times per day as clouds pass. Each impeller lifts independently, providing automatic wear compensation and preventing sand lock.
To size a solar pumping system, the following data are required:
Water source – Type (borehole, well, river); static water level; dynamic water level (drawdown); recovery rate.
Daily water requirement (m³/day) – For irrigation, livestock, or domestic use.
Total dynamic head (TDH) – Static lift + friction losses in pipe + delivery head.
Solar irradiance at site – Peak sun hours (PSH) per day (typical: 4‑6 hours in most sunny regions).
Desired pumping hours – Typically 6‑8 hours per day (matching sunlight).
The pump is selected so that at rated solar input, the flow rate × daily pumping hours = daily water requirement.
Simplified formula:Pump power (kW) ≈ (Flow (m³/h) × TDH (m) × 0.0027) / (pump efficiency × VFD efficiency)
For example: 10 m³/h at 50 m TDH with 70% pump efficiency and 95% VFD efficiency:10 × 50 × 0.0027 / (0.7 × 0.95) = 1.35 / 0.665 ≈ 2.0 kW pump power. Solar array: 2.0 kW × 1.2 to 1.5 = 2.4‑3.0 kWp.
| Feature | Benefit |
|---|---|
| No fuel cost | Zero operating fuel expense; only maintenance |
| No grid connection | Ideal for remote fields, rangelands, and off‑grid villages |
| Low maintenance | Fewer moving parts than diesel generators; no oil changes, fuel filters |
| Quiet operation | No engine noise; suitable for residential and wildlife areas |
| Long life | Solar panels last 25+ years; pumps last 5‑10 years (replaceable) |
| Scalable | Add panels and pumps as water demand grows |
| Environmentally friendly | Zero carbon emissions, no fuel spill risk |
| Government incentives | Eligible for renewable energy subsidies and tax credits in many countries |
| Sector | Typical Use | System Type |
|---|---|---|
| Agriculture | Drip irrigation for vegetables, orchards; sprinkler irrigation for pastures; flood irrigation for rice | Submersible (borehole) or surface centrifugal, 2‑30 kW |
| Livestock | Watering cattle, sheep, horses; remote trough filling | Small DC or AC submersible (1‑5 kW) with tank & float switch |
| Rural domestic | Village water supply from borehole to elevated tank; household connections | Submersible multistage (3‑15 kW) with pressure switch |
| Mining | Remote mine dewatering; dust suppression | Large AC submersible (30‑150 kW) with remote monitoring |
| Wildlife & conservation | Waterhole filling; pumping from borehole to artificial ponds | DC or small AC, with level sensors to prevent dry running |
Morning: As sun rises, the controller starts the pump at low speed, increasing as PV power increases.
Cloudy periods: The controller reduces pump speed to match available power – pumping continues (at lower flow) rather than stopping completely.
Noon peak: Pump runs at full rated speed, delivering maximum flow.
Evening: As sun sets, controller smoothly reduces speed and stops when power is insufficient.
Dry‑run protection: If water level drops below the pump intake (dry borehole), the controller stops the pump, protecting the motor and seals. When water level recovers (e.g., after rain), the pump restarts automatically.
Tank full protection: A float switch or hydrostatic pressure sensor signals the controller to stop the pump when the storage tank is full, preventing overflow.
Site survey – Solar access (no shading), borehole location, tank location.
Array mounting – Ground structure tilted to local latitude; ensure stable foundation.
Pump installation – Submersible: lower into borehole; surface: mount on concrete pad, connect suction and discharge piping.
Cabling – UV‑resistant DC cable from array to controller; armoured cable from controller to submersible pump.
Controller wiring – Connect PV input, pump output, sensors, and optional remote monitoring.
System check – Measure insulation resistance, check polarity, verify sensor functions.
Start‑up – Run pump under full sun; measure flow and pressure; adjust VFD parameters if needed.
PV panels: IEC 61215 certified (crystalline silicon) , IEC 61730 for safety.
Controller: CE, RoHS; VFD certified to IEC 61800; surge protection built‑in (Class II).
Pump (submersible): ISO 9906 performance test; hydrostatic test at 1.5x max pressure.
System validation: On‑site commissioning report with flow, head, power, and solar irradiance data.
| Component | Task | Frequency |
|---|---|---|
| Solar panels | Clean dust / bird droppings; inspect for damage | Monthly (more often in dusty areas) |
| Controller | Check display for errors; verify fan (if present) | Quarterly |
| Pump (submersible) | Monitor flow and current; check insulation resistance | Annually or when performance drops |
| Pipes & fittings | Inspect for leaks, corrosion, or UV damage | Semi‑annually |
| Sensors (float, level) | Test operation; clean contacts | Annually |
| Problem | Likely Cause | Solution |
|---|---|---|
| Pump does not start | Low solar radiation (night, heavy clouds), controller fault, dry‑run protection active | Wait for sunlight; check controller display; check water level |
| Pump runs but no water | Air lock, blocked suction screen (surface pump) , borehole dry | Vent air; clean screen; check water level |
| Low flow | Partially shaded array, voltage drop in cable, worn impeller | Clear shading; check cable size; replace impellers |
| Pump stops and restarts frequently | Cloud passing (normal) , dry‑run threshold too high | Normal; adjust settings if false alarms |
| Overvoltage alarm (controller) | Array voltage too high for controller rating | Check array configuration; reduce number of panels in series |
Complete solution – Panels, pump, controller, accessories – one source, one warranty.
MPPT + VFD – Maximum water output from available solar energy; soft start extends pump life.
Standard AC pump option – Uses widely available borehole pumps; easy to replace.
DC pump option – Simple, very efficient for small systems.
Dry‑run & tank‑full controls – Standard; protects pump and prevents waste.
Remote monitoring – Optional GSM / IoT for real‑time flow, pressure, and solar data.
Global service – Spare parts and technical support for pumps, controllers, and panels.
CE / TUV / IEC certified – Compliant with international standards.
Competitive pricing – Factory direct with bulk panel pricing.
| Component | Recommended Quantity (for 5 years) |
|---|---|
| Mechanical seal kit (for submersible pump) | 1 set |
| Pump impeller set (floating) | 1 set |
| Controller spare I/O board (optional) | 1 |
| Surge arrestor (DC side) | 1 |
| Float switch (spare) | 1 |
For detailed selection of the correct solar pumping system – including daily water requirement, borehole depth and drawdown, solar irradiance at site, pump type (submersible DC, submersible AC, or surface), pipe sizing, and controller options – please contact our engineering team.
Email: info@hyrig.com
Our engineers support agricultural irrigation, livestock watering, rural water supply, and remote mining projects worldwide with reliable solar pumping systems – clean, cost‑effective, and off‑grid ready.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.