The 110103-500 Upper IBOP is manufactured to NOV Varco specifications for the TDS-4SA top drive system. As a primary drill string safety barrier, this manual ball valve allows the driller to quickly shut off fluid flow above the top drive, preventing backflow during connections, tripping, or kicks.
Part Number: 110103-500
Type: Manual ball valve
Working Pressure: 5,000 psi (34.5 MPa)
Test Pressure: 7,500 psi (51.7 MPa)
Bore Diameter: 3-1/4" (82.6 mm)
Temperature Range: -20°C to 121°C (-4°F to 250°F)
Body Material: 4130 alloy steel forging
Seals: NBR (nitrile rubber)
Top Connection: 4-1/2" IF female (fits top drive spindle)
Bottom Connection: 3-1/2" IF male
Operation: T-handle, clockwise close / counter-clockwise open
API Standards: API Spec 7-1, API 16D
Direct fit: NOV Varco TDS-4SA
Also compatible (same part number): TDS-8SA, TDS-10SA, TDS-11SA
Not for H₂S service: For sour gas applications, order 110103-502 (NACE MR0175 compliant)
OEM specification – exact match for Varco top drives
Proven reliability – thousands in field service worldwide
Easy maintenance – standard repair kits available
Cross-model commonality – reduces spare parts inventory
Land and offshore drilling with TDS-4SA top drive
Medium-depth wells (≤ 3,500m)
Workover and completion operations
Non-sour environments
Apply API 7-1 thread compound before installation
Torque to 13,500–15,000 N·m (10,000–11,000 ft·lbs)
Pressure test before each run (low and high pressure per API 16D)
Cycle the valve every shift to ensure smooth operation
Recommended service interval: after 300 cycles or 6 months
Upper IBOP (standard): 110103-500
Optional T-handle: 110103-500-HDL
Test sub: 110103-500-TEST
Sour service version: 110103-502