110103-500 | TDS-4SA Upper Inner Blowout Preventer (IBOP)

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
The 110103-500 is an upper inner blowout preventer (IBOP) designed for NOV Varco TDS-4SA top drive systems. Rated at 5,000 psi working pressure with a 3-1/4" full bore, this manual ball valve provides reliable drill string isolation during connections, tripping, and well control events. Built from 4130 alloy steel with NBR seals, it meets API 7-1 and API 16D standards. Also compatible with TDS-8SA/10SA/11SA.

Conatct For Details
DetailReview(0)Additional

Varco Top Drive IBOP for Reliable Well Control

The 110103-500 Upper IBOP is manufactured to NOV Varco specifications for the TDS-4SA top drive system. As a primary drill string safety barrier, this manual ball valve allows the driller to quickly shut off fluid flow above the top drive, preventing backflow during connections, tripping, or kicks.

Key Specifications

  • Part Number: 110103-500

  • Type: Manual ball valve

  • Working Pressure: 5,000 psi (34.5 MPa)

  • Test Pressure: 7,500 psi (51.7 MPa)

  • Bore Diameter: 3-1/4" (82.6 mm)

  • Temperature Range: -20°C to 121°C (-4°F to 250°F)

  • Body Material: 4130 alloy steel forging

  • Seals: NBR (nitrile rubber)

  • Top Connection: 4-1/2" IF female (fits top drive spindle)

  • Bottom Connection: 3-1/2" IF male

  • Operation: T-handle, clockwise close / counter-clockwise open

  • API Standards: API Spec 7-1, API 16D

Compatibility & Interchangeability

  • Direct fit: NOV Varco TDS-4SA

  • Also compatible (same part number): TDS-8SA, TDS-10SA, TDS-11SA

  • Not for H₂S service: For sour gas applications, order 110103-502 (NACE MR0175 compliant)

Why Choose 110103-500?

  • OEM specification – exact match for Varco top drives

  • Proven reliability – thousands in field service worldwide

  • Easy maintenance – standard repair kits available

  • Cross-model commonality – reduces spare parts inventory

Applications

  • Land and offshore drilling with TDS-4SA top drive

  • Medium-depth wells (≤ 3,500m)

  • Workover and completion operations

  • Non-sour environments

Installation & Maintenance

  • Apply API 7-1 thread compound before installation

  • Torque to 13,500–15,000 N·m (10,000–11,000 ft·lbs)

  • Pressure test before each run (low and high pressure per API 16D)

  • Cycle the valve every shift to ensure smooth operation

  • Recommended service interval: after 300 cycles or 6 months

Ordering Information

  • Upper IBOP (standard): 110103-500

  • Optional T-handle: 110103-500-HDL

  • Test sub: 110103-500-TEST

  • Sour service version: 110103-502

Need a Quote or Technical Support?

Contact our team for 110103-500 Upper IBOP, repair kits, or field installation guidance.

Email: info@hyrig.com

*We also supply Lower IBOP 114706-500/502 and top drive components for TDS-4SA, -8SA, -10SA, and -11SA.*


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit