This product family includes upper and lower inner blowout preventers (IBOP) manufactured to NOV Varco specifications for TDS-4SA, TDS-8SA, TDS-10SA, and TDS-11SA top drive systems. These manual ball valves provide primary (upper) and secondary (lower) drill string isolation during connections, tripping, and well control events.
All standard models are rated at 5,000 psi working pressure with a 3-1/4” full bore, constructed from 4130 alloy steel with NBR seals. For sour gas environments containing hydrogen sulfide (H₂S), sour service versions are available with HNBR seals and NACE MR0175 / ISO 15156 compliant materials.
Manual ball valve design, T-handle operation (clockwise close)
Working pressure: 5,000 psi (34.5 MPa); test pressure: 7,500 psi (51.7 MPa)
Temperature range: -20°C to 121°C (-4°F to 250°F)
API Spec 7-1 and API 16D compliant
Cross-compatible across TDS-4SA, TDS-8SA, TDS-10SA, TDS-11SA
| Position | Part Number | Service | Top Drive Fit | Seals | Material |
|---|---|---|---|---|---|
| Upper IBOP | 110103-500 | Standard | TDS-4SA/8SA/10SA/11SA | NBR | 4130 steel |
| Upper IBOP | 110103-502 | Sour service | TDS-11SA (also fits others) | HNBR | NACE MR0175 |
| Lower IBOP | 114706-500 | Standard | TDS-4SA/8SA/10SA/11SA | NBR | 4130 steel |
| Lower IBOP | 114706-502 | Sour service | TDS-11SA (also fits others) | HNBR | NACE MR0175 |
Direct fit: TDS-4SA, TDS-8SA, TDS-10SA, TDS-11SA
Top connection: 4-1/2” IF female
Bottom connection: 3-1/2” IF male
Application: Non-sour wells, primary barrier
Direct fit: TDS-11SA (compatible with other TDS models)
Certification: NACE MR0175 / ISO 15156
Application: Wells with H₂S, acidic gas environments
Direct fit: TDS-4SA, TDS-8SA, TDS-10SA, TDS-11SA
Role: Secondary barrier below top drive
Application: Non-sour drilling operations
Direct fit: TDS-11SA
Certification: NACE MR0175
Application: Sour gas wells, secondary isolation
All four part numbers (standard versions) are fully interchangeable across the TDS-4SA, TDS-8SA, TDS-10SA, and TDS-11SA top drives. This commonality simplifies spare parts inventory for fleets with multiple TDS models.
The sour service versions (110103-502 and 114706-502) are primarily intended for TDS-11SA but will physically fit other TDS models; however, for full NACE compliance, verify the top drive’s own material compatibility.
Apply API 7-1 thread compound before installation
Tightening torque: 13,500 – 15,000 N·m (10,000 – 11,000 ft·lbs)
Pressure test after installation per API 16D (low and high pressure)
Cycle the valve every shift to ensure smooth operation
Recommended seal replacement after 300 cycles or 6 months
For sour service, use NACE-approved thread lubricant and follow H₂S handling procedures
Land and offshore drilling with Varco TDS series top drives
Medium to ultra-deep wells
Workover and completion operations
Sour gas fields (with -502 versions)
We supply the complete range of upper and lower IBOP for TDS series top drives. Each unit comes with factory test report and API 16D documentation.
Contact for quotes, stock availability, or technical data sheets:
Email: info@hyrig.com
Also available: repair kits, T-handles, test subs, and full top drive spare parts.