Urea Solution Transfer Pump | API 610 Centrifugal Process Pump China Manufacturer

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
API 610 urea solution transfer pump for fertilizer and chemical plants. Engineered to handle urea solution and ammonium carbamate at elevated temperatures. Features corrosion-resistant materials, optional steam jacket for crystallization prevention, and API 682 mechanical seal compatibility. Designed for high reliability in continuous service. Manufactured in China with full API 610 11th Edition compliance. Customizable for temperature, capacity, and head requirements.

Conatct For Details
DetailReview(0)Additional

Overview & Definition

The Urea Solution Transfer Pump is an API 610 Type OH2 horizontal, single‑stage, overhung, centerline‑mounted centrifugal pump specifically engineered for handling urea solution (CO(NH₂)₂ aqueous solution) and related corrosive process fluids in fertilizer plants, urea production units, and chemical processing facilities. The pump is fully compliant with API 610 11th Edition and ISO 13709 standards, ensuring heavy‑duty reliability for continuous, critical service in the urea and fertilizer industry.

What is a Urea Solution Transfer Pump?

In urea manufacturing and downstream processing facilities, aqueous urea solution must be transferred between various process stages, including:

  • From the synthesis section to evaporation and concentration units

  • Between storage tanks and distribution headers

  • From storage to granulation, prilling, or bagging systems

  • In urea‑based selective catalytic reduction (SCR) systems for NOx reduction

  • In urea ammonium nitrate (UAN) solution blending and transfer

Urea solution is typically operated at elevated temperatures (60–120°C, depending on concentration and process stage) to prevent crystallization, as urea solution tends to solidify or form crystals when temperature drops below its saturation point.

Why API 610 for Urea Solution Service?

API 610 is the global standard for centrifugal pumps used in petroleum, petrochemical, and natural gas industries, emphasizing reliability, safety, and long service life in demanding applications. The standard covers design, materials, manufacturing, testing, and inspection requirements.

For urea solution transfer, API 610 compliance ensures:

  • Corrosion resistance — through appropriate material selection from API 610 Table H‑1, which specifies wetted material classes suitable for corrosive urea and ammonium carbamate service

  • Thermal stability — centerline mounting accommodates thermal expansion at elevated temperatures

  • Leak prevention — API 682 compliant seal chambers supporting double mechanical seals for zero‑leakage containment of corrosive and hazardous urea solutions

  • Maintenance efficiency — back pull‑out design allows internal component removal without disturbing piping

  • Long service life — heavy‑duty construction ensures 3–5 years continuous operation between overhauls

As a specialized China API 610 pump manufacturer, we produce fully API 610 11th Edition compliant urea solution transfer pumps that satisfy the rigorous demands of the fertilizer industry while offering competitive cost and lead time advantages.

Media Compatibility

This pump series is specifically engineered for handling urea‑based solutions and related corrosive process fluids:

Primary Media:

  • Urea solution (aqueous) — CO(NH₂)₂ dissolved in water; concentrations typically 20–80%

  • Melt urea — molten urea at elevated temperatures (120–180°C)

  • Ammonium carbamate solution — corrosive intermediate in urea synthesis

  • Urea ammonium nitrate (UAN) solution — liquid fertilizer blend

Non‑suitable applications: Carbon steel and standard austenitic stainless steels (304, 316) have insufficient resistance to ammonium carbamate corrosion. For carbamate service, super duplex (25% Cr) or higher alloys are mandatory.

Fluid Characteristics and Engineering Challenges:



CorrosivityUrea solutions are moderately corrosive at elevated temperatures. Decomposition products (biuret, ammonia, ammonium carbamate) increase corrosion rates. Ammonium carbamate — the intermediate formed during urea synthesis — is highly corrosive and causes rapid degradation of carbon steel and austenitic stainless steels.
Crystallization tendencyUrea solution tends to crystallize when temperature drops below its saturation point (typically around 60–70°C for concentrated solutions). Crystallization within the pump casing, seal chamber, or piping can cause severe damage — wear ring galling, seal failure, impeller blockage, and shaft seizure. Pump designs commonly incorporate steam jackets or heating elements to maintain temperature.
Temperature range60–120°C typical for aqueous urea solution; up to 180°C for melt urea. Low temperature is not generally an issue, but proper heat tracing and temperature monitoring are critical.
Abrasive potentialUrea may contain small amounts of solid impurities (biuret, dust, corrosion products). Though primarily clean, solids can accelerate wear of wear rings, bushings, and seal faces.
Toxicity and handlingUrea solutions are not acutely toxic, but repetitive skin contact may cause dermatitis. Ammonium carbamate is highly corrosive and toxic — zero‑leakage sealing is mandatory for carbamate service.

Material Selection Considerations for Urea Solution Transfer Pumps:

Material selection must consider both urea solution and the corrosion potential of decomposition products (ammonium carbamate). The table below summarizes standard material choices for urea solution pumps:

MaterialUrea Solution Corrosion ResistanceAmmonium Carbamate ResistanceSuitabilityCost Level
Carbon SteelPoor — rapid corrosion at elevated temperaturesNot suitableNot recommendedLow
304 Stainless SteelFair — limited pitting resistanceNot suitable (corrodes rapidly)Limited — for low‑temperature, low‑concentration urea onlyModerate
316/316L Stainless SteelGood — acceptable for urea solution serviceNot recommendedAcceptable for urea solution (not carbamate)Moderate
Duplex 2205Excellent — superior pitting and stress corrosion resistanceFair — limited for high‑temperature carbamateGood for urea solution and moderate carbamate exposureModerate‑High
Super Duplex 2507ExcellentGood — higher resistance than 2205Recommended for urea service with carbamate riskHigh
25% Cr Super DuplexExcellentExcellentPreferred for ammonium carbamate service (e.g., Apollo custom design)Very High
Higher Alloys (Hastelloy, Inconel)ExcellentExcellentSpecialized for extreme conditionsHighest

Recommendation for urea solution transfer pump: 316L stainless steel is the standard, cost‑effective choice for clean urea solution service without significant ammonium carbamate exposure. For urea service involving carbamate recirculation or higher corrosion risk conditions, super duplex (≥25% Cr) is mandatory.

O‑ring and gasket selection: Use PTFE, FFKM (Kalrez/Chemraz), or EPDM (urea‑compatible). Avoid natural rubber, silicone, or Buna‑N in contact with urea or carbamate service.

Selection Guidelines for Urea Solution Transfer Pumps

Selecting the correct API 610 urea solution transfer pump requires systematic evaluation of process parameters, fluid properties, and installation conditions.

Step 1: Define Operating Conditions

Accurate operating data is the foundation of proper pump selection. Key parameters needed:

ParameterRequired Information
Flow rate (Q)Rated flow, normal flow, minimum flow
Total head (H)Discharge pressure (or head) at rated flow
Fluid temperatureOperating range (minimum, normal, maximum)
Fluid compositionUrea concentration, additives, potential decomposition products
Corrosion potentialPresence of ammonium carbamate, chlorides, or other aggressive species
NPSH available (NPSHa)Suction side conditions at pump inlet
ViscosityUrea solution viscosity varies with concentration and temperature
Specific gravityDensity relative to water at operating temperature
Solids contentParticulate concentration (if present)
Operating cycleContinuous or intermittent; expected hours per year

Step 2: Determine Pump Type

For urea solution transfer service, pump types are selected based on flow rate, head, and installation requirements:

Flow Range (m³/h)Head Range (m)Recommended Pump Type
1 – 300Up to 150API 610 OH2 — Horizontal, single‑stage, overhung (most common for urea solution transfer)
10 – 500Up to 250API 610 OH2 or OH1 — Depending on baseplate and mounting requirements
0.5 – 60Up to 400Integrally geared high‑speed pump (for low‑flow, high‑head urea circulation)
100 – 2,60020 – 300API 610 OH2 larger frame sizes
Multistage requirements>250 mAPI 610 BB3 or BB5 (rare for standard urea transfer; may be specified for urea melt pumping)

Step 3: Select Pump Size and Speed

Once pump type is selected, the specific pump size (impeller diameter, casing size) and operating speed are determined to meet the required flow and head while maximizing efficiency. The rated operating point should generally be selected within 70–120% of the Best Efficiency Point (BEP) to ensure reliable operation and extended component life.

Step 4: Select Materials of Construction

Material selection is the most critical aspect of urea solution pump specification. The following matrix provides guidance:

ComponentStandard MaterialOptional Upgrade
Casing316L Stainless SteelDuplex 2205 / Super Duplex 2507 / 25% Cr for carbamate
Impeller316L Stainless Steel (closed)Duplex 2205 / Super Duplex
Shaft316L or 17‑4PH Stainless SteelDuplex 2205
Wear Rings316L with hard facingTungsten carbide / Stellite coating
Mechanical Seal FacesSilicon carbide vs. carbonTungsten carbide vs. silicon carbide
O‑rings & GasketsPTFE or EPDMFFKM (high‑temperature service)
Casing BoltingA193 B8M (316 SS)Duplex / Monel

Step 5: Determine Temperature Management Requirements

Urea solution crystallization below approximately 70°C is the most common operational problem with urea pumps. Temperature management requirements include:

  • Steam jackets — Recommended for concentrated urea solution and melt urea service. Steam jackets are integral to the pump casing (front and back covers), allowing low‑pressure steam (typically ≤0.6 MPa, up to 170°C) circulation to maintain fluid temperature above the crystallization point.

  • Heat tracing — For external piping associated with the pump, electrical or steam heat tracing should be considered to prevent crystallization in dead legs and low‑flow areas.

  • Bearing housing cooling — For high‑temperature service (>120°C), water‑cooled bearing housings are recommended to keep bearing temperatures within safe operating limits (≤75°C).

Step 6: Select Seal System

Seal selection for urea solution service is driven by fluid corrosivity and crystallization tendency:

Service TypeRecommended Seal ConfigurationAPI 682 Flush Plan
Clean urea solution (≤80°C)Single mechanical sealPlan 11 (internal recirculation + orifice) or Plan 02 (dead‑ended)
Urea solution with crystallization riskTandem mechanical sealPlan 52 (unpressurized buffer fluid) — quench prevents crystal accumulation
Corrosive urea / carbamate serviceDouble mechanical sealPlan 53B (pressurized barrier fluid reservoir) — zero leakage
High‑temperature urea meltDouble mechanical seal with coolingPlan 53B with cooler, or Plan 54 (external barrier fluid circulation)

Step 7: Specify Auxiliary Features

Based on the specific service conditions, additional features may be required:

Auxiliary FeatureRequired When
Steam jacket on casingConcentrated urea solution or melt urea service (temperature required above crystallization point)
Bearing housing coolingOperating temperature >100°C
Minimum flow recirculationSystem may operate below pump minimum continuous stable flow
Heating elements in seal chamberCold startup conditions or risk of seal face crystallization
Flushing connections in casingService where periodic cleaning for crystallized deposits may be required
NACE complianceSulfide‑containing environments (not typical for urea service)

Step 8: Additional Considerations for Urea Solution Pumps

Beyond standard hydraulic selection, urea solution pumps require special attention to:

Crystallization Prevention Design:

  • Avoid dead legs within the pump casing. Design the internal flow passage to ensure continuous flow across all wetted surfaces.

  • Provide steam jackets on the front and back casing covers, and wherever deposition is likely.

  • Maintain the entire wetted path at a temperature above the urea saturation point — typically 5–10°C margin.

  • Use flush plans that continuously purge the seal chamber when the pump is idle to prevent crystal buildup.

Corrosion Margin:

  • Urea solution is inherently corrosive at elevated temperatures. Adding 2–3 mm corrosion allowance is typical practice for 316L wetted parts if extended service life (10+ years) is required without material replacement.

  • Avoid sharp corners and crevices in flow passages where pitting corrosion can initiate.

Abrasion Handling:

  • For urea containing trace solids (e.g., biuret or corrosion products), tungsten carbide seal faces reduce wear rates.

  • Hard‑faced (Stellite) wear rings resist galling.

Seal Flush Considerations:

  • For Plan 11 (internal recirculation), use an orifice sized for the specific service to control flow. Flush fluid recirculated from discharge must remain above crystallization temperature — verify orifice sizing does not result in excessive temperature drop across the seal chamber.

  • For carbamate service, Plan 53B with clean barrier fluid is mandatory; carbamate must never contact the atmosphere.

Third‑Party Standards: Pump testing and inspection should follow API 610 requirements, including hydraulic performance testing (Q‑H, efficiency, NPSH3), mechanical run testing, vibration and bearing temperature monitoring, and hydrostatic testing of the casing at 1.5× design pressure. For urea service, additional material verification (PMI testing) and hardness checks may be requested by end users.

Pump Design Features for Urea Solution Service

API 610 urea solution transfer pumps incorporate design features specifically addressing the unique challenges of this service:

Back Pull‑Out Design: The rotating assembly (impeller, shaft, mechanical seal, bearing housing) can be removed without disturbing the pump casing or piping connections. This feature significantly reduces maintenance downtime — critical for continuous urea plant operations.

Centerline Mounting: The casing is supported at the horizontal centerline, allowing symmetrical thermal expansion. For urea solution at 60–120°C, this prevents misalignment that would otherwise shorten seal and bearing life.

Steam Jacket (Optional): For melt urea or concentrated solution service, the casing is furnished with an integral steam jacket. Low‑pressure steam (≤0.6 MPa, up to 170°C) circulates through the jacket, maintaining the wetted surfaces above the urea crystallization temperature. Steam jackets are typically provided on both the front and back covers for complete coverage.

Renewable Wear Rings: Casing and impeller wear rings are replaceable without replacing the casing or impeller. For urea service, wear rings are hard‑faced to resist galling if crystallization occurs.

API 682 Seal Chamber: The seal chamber is dimensioned to accept all API 682 3rd or 4th Edition cartridge mechanical seals without modification. This allows easy specification of double seals for carbamate service or heated seal chambers for urea melt applications.

Rigid Shaft Design: Large diameter shaft minimizes deflection and ensures stable rotor dynamics, extending mechanical seal life.

Open or Enclosed Impeller: Although standard API 610 pumps normally use enclosed impellers, open impeller configurations are occasionally specified for urea service to tolerate small solids from crystallization or decomposition products while minimizing clogging risk.

Industry Applications

API 610 urea solution transfer pumps are essential equipment across multiple fertilizer and chemical process applications:

Urea Production Plants:

  • Transfer of urea solution from synthesis section to evaporation section

  • Circulation between evaporation stages

  • Feed to prilling tower or granulation unit

  • Recycle of off‑spec urea solution

Urea Formulation and Blending:

  • Urea ammonium nitrate (UAN) solution mixing and transfer

  • Urea‑based suspension fertilizer circulation

  • Dilution and blending of concentrated urea solution

Urea Storage and Distribution:

  • Loading pumps for railcars and tank trucks

  • Unloading pumps from bulk storage

  • Circulation between storage tanks

  • Transfer to day tanks and process headers

Selective Catalytic Reduction (SCR) Systems:

  • Urea solution feed pumps for NOx reduction in power plants, cement plants, and marine applications

  • Recirculation pumps for urea‑based SCR systems

  • Transfer between urea storage and injection skids

Coal Chemical and Petrochemical:

  • Urea solution transfer in coal‑to‑urea complexes

  • Ammonia‑urea handling in integrated fertilizer facilities

General Chemical Processing:

  • Transfer of urea‑containing process streams

  • Corrosive fluid transfer requiring API 610 reliability

Why Choose a China API 610 Urea Solution Pump Manufacturer?

As a specialized China API 610 pump manufacturer with extensive experience in urea and fertilizer applications, we deliver:

  • Full API 610 11th Edition (ISO 13709) compliance — designed, manufactured, and tested to the same rigorous standards as leading global brands

  • Corrosion‑resistant material selection — 316L stainless steel, duplex, super duplex, and specialized alloys available

  • Crystallization prevention design — steam jackets, proper flush plans, and temperature management features integrated into the design

  • Competitive capital cost — typically 25–35% lower than major Western brands for equivalent API 610 configurations

  • Shorter lead times — 16–24 weeks ARO for standard material configurations

  • Complete engineering documentation — hydraulic performance curves, NPSH curves, sectional drawings, GA drawings, API 610 data sheets, material certifications, and installation/maintenance manuals

  • Factory performance testing — witnessed and non‑witnessed options, including hydraulic performance testing, mechanical run testing, vibration monitoring, and bearing temperature monitoring

  • API 682 seal support systems — complete seal flush panels, reservoirs, and coolers supplied and tested as integrated packages

  • Global shipping and export packaging — wooden crates, VCI, desiccant, and full export documentation

  • Spare parts availability — critical spares stocked; complete spare parts kits available for scheduled overhauls

  • Installation and commissioning support — on‑site supervision, training, and after‑sales service available

Summary for Urea Solution Transfer Pump

ParameterSpecification
Pump TypeAPI 610 Type OH2 — horizontal, single‑stage, overhung, centerline‑mounted
MediumUrea solution (aqueous CO(NH₂)₂), melt urea, UAN, ammonium carbamate
Temperature Range-20°C to +180°C (typical urea solution: 60–120°C)
Flow Range1 – 2,600 m³/h (selected to process requirements)
Head RangeUp to 250 m per stage (higher available with multistage configurations)
Flange RatingASME Class 150 / 300 / 600
Materials (Standard)316L Stainless Steel — suitable for clean urea solution service
Materials (Upgrade)Duplex 2205 / Super Duplex 2507 — for enhanced corrosion resistance and carbamate service
Mechanical SealsAPI 682 compliant single/tandem/double cartridge seals; Plan 11, 52, or 53B
Auxiliary FeaturesSteam jacket (optional), bearing housing cooling, minimum flow recirculation
CertificationAPI 610 11th Edition (ISO 13709)
MaintenanceBack pull‑out design — internal components removable without disturbing piping

For more information or a custom engineering proposal for your urea solution transfer pump application, please contact us at:

info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code