The Ammonia Refrigeration Circulation Pump is an API 610 Type OH6 vertical, integrally geared, high speed centrifugal pump specifically engineered for circulating liquid ammonia (R717 refrigerant) in industrial refrigeration systems. The pump handles liquid ammonia at low temperatures with moderate to high discharge pressures, delivering reliable refrigerant circulation from low pressure receiver to evaporator coils in ammonia-based refrigeration systems.
The OH6 configuration is a compact, high speed, integrally geared single-stage overhung pump. It incorporates a built-in speed-increasing gearbox seamlessly integrated with the pump assembly. The impeller is directly attached to the output shaft of the gearbox, enabling high rotational speeds that deliver multistage pump performance from a single-stage design. Unlike conventional multistage pumps, the OH6 achieves high head and moderate flow through high rotational speed rather than multiple impeller stages, significantly reducing the pump's physical footprint and weight — only 25% the size of competing horizontal pumps for equivalent hydraulic performance.
In industrial refrigeration systems, ammonia (R717) is the most widely used natural refrigerant, serving applications such as food processing and cold storage, ice rinks and freezing tunnels, petrochemical and chemical process cooling, cold chain logistics warehouses, and large HVAC systems. The ammonia circulation pump must operate reliably at low temperatures (often below -30°C) while preventing refrigerant leakage, avoiding cavitation under low NPSH conditions, and providing continuous, maintenance‑free service.
As a specialized China OH6 pump manufacturer, we produce fully API 610 11th Edition (ISO 13709) compliant integrally geared high speed pumps for ammonia refrigeration circulation, hydrocarbon processing, and other demanding low flow, high head services.
The Ammonia Refrigeration Circulation Pump is specifically engineered for handling liquid ammonia (anhydrous NH₃, R717 refrigerant) and other low temperature refrigerants:
Primary Media:
Liquid ammonia (R717) — natural refrigerant used in industrial cooling systems
Anhydrous ammonia — pure NH₃ without water content
Ammonia with trace lubricating oil — oil carryover from refrigeration compressors
Fluid Characteristics and Engineering Challenges:
Operating Temperature: -30°C specified (OH6 design range: -130°C to +340°C)
Operating Pressure: 3.0 MPa / 30 bar (suction or system pressure)
Non-lubricating fluid: Liquid ammonia has very low lubricity, requiring appropriate bearing material selection and seal design
Low viscosity and low specific gravity: Density approximately 0.63–0.68 g/cm³ at -30°C — requires careful hydraulic design to maintain efficiency
High vapor pressure at low temperatures: Liquid ammonia boils at -33°C at atmospheric pressure; pump must maintain adequate NPSH available above vapour pressure to prevent cavitation. At -30°C, the saturation pressure is approximately 1.17 MPa absolute; the specified 3.0 MPa system pressure provides significant NPSH margin.
Toxicity and flammability: Ammonia is toxic and forms flammable mixtures in air; zero‑leakage sealing is mandatory
Corrosion properties: Liquid ammonia does not corrode carbon steel when dry, but becomes corrosive in the presence of moisture. Ammonia causes stress corrosion cracking in certain materials.
Temperature sensitivity: Ammonia experiences significant density and viscosity changes with temperature, requiring pump performance verification across the operating range.
Centrifugal refrigerant pumps handling ammonia must be:
Leak‑proof — with double seals for hazardous refrigerants like NH₃
Cavitation-resistant — low NPSHr design essential
Corrosion-resistant — stainless steel construction recommended for ammonia
Material Selection for Liquid Ammonia at -30°C, 3.0MPa:
| Component | Recommended Material | Alternative |
|---|---|---|
| Pump Casing | 316L Stainless Steel | Duplex 2205 SS |
| Impeller | 316L Stainless Steel (enclosed) | Duplex 2205 SS |
| Shaft | 17-4PH Stainless Steel | Duplex 2205 SS |
| Gearbox Housing | Ductile iron / Carbon steel | — |
| Fasteners | A193 B8M (316 SS) | Duplex |
| O-Rings / Seals | FFKM (Kalrez/Chemraz) or PTFE | EPDM (limited life; not recommended) |
| Mechanical Seal Faces | Silicon carbide vs. carbon | Tungsten carbide vs. carbon |
Material rationale: 316L stainless steel provides excellent low temperature toughness, corrosion resistance to anhydrous ammonia, and maintains strength at -30°C without experiencing ductile‑to‑brittle transition issues encountered by carbon steel in low temperature service. For applications with higher chlorides or sour service conditions, upgrade to Duplex 2205.
Not recommended: Brass, copper, bronze, or galvanized materials — ammonia attacks copper alloys causing rapid failure.
Extended Applications (Same Pump Platform):
Beyond liquid ammonia refrigeration circulation, the API 610 OH6 integrally geared pump platform serves a broad range of low flow, high head, medium to high temperature industrial services:
Refrigerant circulation — R22, R134a, R404A, R507, propane (R290), CO₂ (R744)
Hydrocarbon processing — light hydrocarbon feed, booster, bottoms, reflux pumps in refineries and NGL facilities
Chemical and petrochemical — acid feed and recirculation, polypropylene feed, styrene, acetic acid, amines, methanol
Power generation — fuel oil feed, boiler fuel injection, NOx recirculation, condensate circulation
Gas processing — amine recirculation, glycol dehydration pumps, sour water pumps
General industrial — wash water, seal flush, descaling, injection
The API 610 OH6 integrally geared high speed pump covers a targeted operating envelope optimized for low flow, high head applications:
General OH6 Parameter Range:
| Parameter | Value / Range |
|---|---|
| Pump Type | API 610 Type OH6 – vertical, integrally geared, single-stage overhung |
| Flow Rate (Q) | 0.5 ~ 250 m³/h |
| Total Head (H) | 300 ~ 3,050 m |
| Operating Temperature | -30°C (design range: -130°C to +340°C) |
| Design Pressure (Suction) | 3.0 MPa / 30 bar (standard rating up to 7.0–10.0 MPa) |
| Speed (pump shaft) | 4,900 ~ 22,700 rpm (gear ratio selected for application) |
| Motor Speed | 2,980 / 3,600 rpm (50/60 Hz, standard induction motor) |
| Casing Construction | Vertical inline, single-stage, partial-flow diffuser type |
| Impeller Type | Enclosed, open straight blade; Barske impeller low NPSH technology |
| Flange Rating | ANSI Class 600 RF (standard); Class 900 RF (optional) |
| Materials | 316L SS, duplex SS, carbon steel (gearbox housing) |
| Maximum Motor Power | Up to 900 kW |
Specific Duty (Liquid Ammonia / -30°C / 3.0MPa):
The specified duty falls well within the OH6 operating envelope. The low temperature (-30°C) is comfortably supported; the 3.0 MPa suction pressure is moderate relative to the pump's maximum suction pressure capability.
Typical Size Reference for Ammonia Refrigeration:
Small systems (cold storage, process cooling) — flow: 5–20 m³/h, head: 300–800 m, motor: 15–50 kW
Medium systems (food processing, ice rinks) — flow: 20–50 m³/h, head: 400–1,200 m, motor: 50–150 kW
Large industrial systems (petrochemical, district cooling) — flow: 50–150 m³/h, head: 600–1,500 m, motor: 150–400 kW
API 610 OH6 Manufacturers — Representative Parameter Ranges:
| Manufacturer | Model | Flow (m³/h) | Head (m) | Pressure | Temp (°C) | Power (kW) |
|---|---|---|---|---|---|---|
| Sundyne | LMV 311 | Up to 73 | Up to 1,348 | 7.1 MPa | -130 to +340 | 150 |
| Sundyne | LMV 313 | Up to 236 | Up to 546 | 3.6 MPa | -130 to +340 | 150 |
| Sundyne | LMV 322 | Up to 52 | Up to 915 | 3.2 MPa | -130 to +340 | 37 |
| Sundyne | LMV 331 | Up to 91 | Up to 1,400 | 7.1 MPa | -130 to +340 | 250 |
| Sundyne | LMV 341 | Up to 91 | Up to 1,921 | 7.1 MPa | -130 to +340 | 315 |
| Zhejiang Tiande | OH-6 | Up to 210 | Up to 3,050 | N/A | N/A | 900 |
| Anhui Huasheng | GSB Series | 0.5–90 | 20–1,800 | 15/25 MPa | Up to 260 | Up to N/A |
| RCP (Beloni) | RCP-V1 | Up to 150 | Up to 1,920 | 6.8 MPa | -130 to +340 | 132 |
| RCP (Beloni) | RCP-V4 | Up to 250 | Up to 2,180 | 6.8 MPa | -130 to +340 | 355 |
The API 610 OH6 ammonia refrigeration circulation pump incorporates a comprehensive suite of design features specifically optimized for low temperature refrigerant handling, low NPSH conditions, and high‑head, low‑flow requirements:
| Feature | Description |
|---|---|
| Integrally Geared Construction | A built‑in speed‑increasing gearbox is seamlessly integrated with the pump assembly. The gearbox is driven by a standard speed electric motor (2,980/3,600 rpm) and increases rotational speed to the impeller shaft (up to 22,700 rpm). This eliminates the need for complex, high‑speed motor drivers and simplifies the overall drive train. The integral design makes the pump extremely compact and saves valuable plant floor space — only 25% the size of competing horizontal multistage pumps. |
| Single‑Stage, High‑Speed Impeller | Despite achieving heads comparable to 8–15 stage multistage pumps, the OH6 pump uses a single impeller. The high rotational speed generates high peripheral velocity, producing high head in a single stage. The impeller is directly attached to the output shaft of the gearbox with no intermediate coupling, ensuring precise alignment and eliminating coupling‑related failure modes. Available impeller types include: • Barske impeller — proprietary low NPSH design with integral inducer vanes; reduces NPSH required by up to 70% compared to conventional impellers, critical for ammonia refrigeration where suction conditions may be marginal • Open straight blade centrifugal impeller — optimized for high efficiency and stable performance across the operating range All impellers are dynamically balanced to ISO 1940 Grade G2.5 or higher. |
| Partial‑Flow Diffuser Design | The pump employs a partial‑flow / part‑flow diffuser type casing rather than conventional volute casing. The diffuser converts velocity energy to pressure with very high efficiency, even at the low flow rates typical of ammonia refrigeration circulation. The diffuser design also significantly reduces radial hydraulic loads, minimizing shaft deflection and extending bearing and seal life. |
| Vertical Inline Configuration | The pump is vertically mounted with inlet and outlet flanges in‑line (on the same centerline). This allows the pump to be installed directly into the piping system like a valve, eliminating the need for heavy foundation blocks and saving floor space — critical for retrofits and skid‑mounted refrigeration packages. The pump body has strong structural rigidity and high load‑bearing capacity for external piping forces. |
| Compact, Space‑Saving Footprint | The OH6 pump occupies only 25% of the floor space required by an equivalent horizontal multistage pump. For refrigeration plants where equipment room space is at a premium, this compact footprint offers significant advantages for new installations and retrofits. |
| Low NPSH Performance | The high rotational speed and Barske impeller design (with integral inducer) provide exceptionally low NPSH required (NPSHr). This is critical for ammonia refrigeration systems where the available NPSH may be limited, particularly: • Low submergence in receiver tanks • Warm ammonia return from evaporators at near‑saturation conditions • Systems with limited elevation head between receiver and pump |
| API 682 Seal Chamber | Seal chamber fully complies with API 682 4th Edition (3rd Edition also supported). For liquid ammonia refrigeration service (toxic, hazardous refrigerant), the following seal arrangements are recommended: • Double mechanical seal with Plan 53B (pressurized barrier fluid reservoir with bladder accumulator) — preferred for zero ammonia leakage; barrier fluid (typically compatible oil or water‑glycol mixture) is pressurized 1–3 bar above pump suction pressure, ensuring ammonia cannot escape to atmosphere • Tandem seal with Plan 52 (unpressurized buffer fluid reservoir) — suitable for less critical applications where continuous leakage monitoring is acceptable • Seal faces: Silicon carbide vs. carbon (standard) / tungsten carbide vs. silicon carbide (abrasive service) • Secondary seals: FFKM (Kalrez/Chemraz) or PTFE — EPDM not suitable for anhydrous ammonia |
| Integral Gearbox | The speed‑increasing gearbox is fully integrated into the pump assembly, eliminating the need for a separate gearbox and coupling between motor and gearbox. The gearbox housing also serves as the pump's mounting structure. Forced oil lubrication or splash lubrication systems available based on power rating and speed. Features include: • Precision ground helical gears for quiet, smooth operation • Generous safety margins for continuous duty • Oil sight glass and temperature monitoring provisions • Optional oil cooler for high‑power applications |
| Close‑Coupled Motor | The electric motor is mounted directly on the pump/gearbox assembly, eliminating flexible couplings and the alignment requirements associated with separated drive configurations. For larger sizes, a spacer coupling between motor and gearbox can be provided. |
| Bearing System | • Gearbox bearings: Heavy‑duty anti‑friction bearings (angular contact and cylindrical roller) designed for high speed continuous operation; forced oil or splash lubrication • Pump shaft bearings: Process‑lubricated or separate bearing arrangement depending on design • Bearing temperature monitoring provisions as standard • Bearing housing cooling: fan or finned cooling for moderate applications; water cooling for high power or high ambient conditions |
| Casing Construction | The pump casing is designed as a vertical inline partial‑flow diffuser type with symmetrical inlet/outlet flanges on a horizontal line. Casing materials are selected for low temperature toughness (316L SS for ammonia service). Renewable casing wear rings are provided to restore efficiency after extended operation. |
| Maintenance Features | • Modular cartridge design allows complete rotating assembly removal without disturbing piping • Gearbox and pump section accessible for inspection without full disassembly • Seal replacement possible without removing motor or gearbox on most models • Designed for 5+ years of continuous operation between scheduled overhauls |
The OH6 ammonia circulation pump is installed at the outlet of the low pressure receiver or surge drum, pumping liquid ammonia at saturation temperature (typically -30°C to -10°C depending on system design) to evaporators located throughout the facility. System integration considerations include:
Piping system: The pump must be installed with proper pipe supports to avoid imposing excessive nozzle loads. The vertical inline configuration accepts significantly higher nozzle loads than equivalent horizontal pumps, accommodating thermal expansion of stainless steel piping systems.
Suction conditions: Adequate NPSH available is critical. The receiver liquid level height above pump suction and the saturation pressure at operating temperature determine available NPSH. The OH6 pump's low NPSHr ensures reliable operation even under marginal suction conditions.
Two‑pump arrangements: Redundant pump configurations (duty/standby or parallel operation) are typical in industrial refrigeration to maintain system uptime. The OH6 pump's vertical footprint preserves floor space even in redundant configurations.
Oil handling: Small amounts of compressor lubricating oil may return to the system with ammonia. The OH6 pump can handle up to minor oil volumes without adverse effects, with appropriate seal selection for oil‑wetted conditions.
| System | Description and Application to Ammonia Refrigeration Service |
|---|---|
| Seal Flush Plan | • Plan 53B (pressurized barrier fluid reservoir with bladder accumulator) — recommended for double seals in toxic ammonia service; barrier fluid pressurized ensures zero leakage to atmosphere • Plan 52 (unpressurized buffer fluid reservoir) — suitable for tandem seal arrangements with leak monitoring • Plan 11 (internal recirculation + orifice) — not recommended for ammonia due to seal reliability concerns • Cooled flush plans (Plan 21/23) — used for high temperature applications; for -30°C ammonia, simple barrier fluid systems without cooling are typically sufficient |
| Lubrication | • Splash lubrication — standard for smaller pumps • Forced oil lubrication — required for high speed or high power models; includes oil reservoir with level sight glass, temperature sensor, optional cooler and filter • Oil type: ISO VG 32–46 synthetic or mineral oil suitable for low temperature operation |
| Bearing Temperature Monitoring | RTD probes (PT100) in gearbox bearing housings, with local indication and 4‑20 mA output for DCS alarm/shutdown. |
| Vibration Monitoring | Accelerometers on gearbox housing for velocity monitoring per API 670. |
| Pressure & Temperature Sensors | Suction and discharge pressure gauges (chemical seal diaphragms recommended to prevent ammonia from reaching instrument) with isolation valves; temperature transmitters on pump suction and discharge. |
| Minimum Flow Protection | Automatic recirculation valve (ARC) or control valve ensures pump never operates below minimum continuous stable flow, preventing overheating and cavitation. For ammonia refrigeration, min flow recirculation is typically returned to the low pressure receiver. |
| Level Monitoring | Low liquid level interlock on receiver to protect pump; ensures sufficient submergence and prevents pump from running dry due to low refrigerant charge. |
| Leak Detection | Gas detector in pump enclosure (when applicable); Seal support system (Plan 53B) includes pressure/temperature monitoring and low barrier fluid level alarm indicating potential seal leakage. |
| Baseplate | For standalone installations, heavy duty steel baseplate, epoxy grouted. For skid‑mounted installations, pump mounts directly to refrigeration package base frame. |
Industrial ammonia refrigeration systems present unique challenges that the OH6 integrally geared pump is ideally suited to address:
Low flow, high head requirements — Ammonia circulation pumps typically require moderate flow (10–100 m³/h) at high head (300–1,500 m) to overcome evaporator pressure drops, piping and valve losses, and static lift. The OH6 pump's high speed design generates multistage head levels in a single stage, eliminating the need for large, costly multistage pumps.
Low NPSH available — Ammonia systems often have limited NPSH available (low submergence, near‑saturation temperatures). The OH6 pump's Barske inducer/impeller technology delivers exceptionally low NPSH required, preventing cavitation-related damage and performance loss.
Toxic refrigerant zero‑leakage requirement — Double mechanical seals with Plan 53B pressurized barrier fluid are required for zero ammonia leakage. The OH6 pump's API 682 seal chamber accommodates all standard API seal configurations, enabling the highest levels of leakage containment.
Space‑saving vertical installation — Refrigeration plants are typically crowded with compressors, vessels, and piping. The OH6 pump's compact vertical inline footprint (25% the size of horizontal equivalents) allows installation in tight spaces, including skid‑mounted refrigeration modules.
Reliability and long service life — Designed and manufactured to API 610 11th Edition, these pumps provide 3‑5 years continuous operation between overhauls. The integral gearbox is designed for the same service life as the pump, with no external coupling to align or maintain. Fewer wetted parts than multistage pumps reduce failure points.
Wide temperature range capability — The OH6 pump's design temperature range (-130°C to +340°C) covers ammonia refrigeration applications from low temperature freezing (‑50°C) to high pressure ammonia feed (ambient‑temperature liquid).
Low vibration, smooth operation — The fully integrated gearbox and impeller assembly, combined with precision‑balanced rotating components, provides exceptionally smooth operation with low vibration levels, extending bearing, seal, and gear life.
The API 610 OH6 integrally geared pump serves critical applications across multiple industrial sectors:
Industrial Refrigeration:
Food processing & cold storage — ammonia circulation in freezing tunnels, chill rooms, and blast freezers
Ice rinks & arenas — recirculated ammonia for ice sheet refrigeration
Cold chain logistics warehouses — evaporator feed at distribution and storage facilities
Protein & meat processing plants — ammonia systems for slaughter, chilling, freezing operations
Dairy & beverage processing — product cooling and cold storage
Petrochemical & Chemical Processing:
Chemical reactors — ammonia circulation for reactor temperature control
Ammonia synthesis loop — refrigeration for synthesis gas cooling
Urea plant refrigeration — evaporator feed for process cooling
Gas processing — propane and mixed refrigerant circulation in NGL/LPG facilities
Hydrocarbon Processing:
Refinery alkylation units — refrigerant circulation for HF alkylation or sulfuric acid alkylation cooling
NGL fractionation — propane and ethane refrigerant circulation
LNG plants — mixed refrigerant circulation (with materials upgrades)
Power Generation:
Gas turbine inlet cooling — ammonia refrigeration for turbine efficiency enhancement
District cooling plants — central ammonia chiller circulation
Renewable Energy:
Green ammonia — refrigeration circulation in clean energy demonstration facilities
Battery energy storage thermal management — liquid cooling using ammonia loops
General Industry:
Pharmaceutical & chemical manufacturing — process and reactor cooling
Printing & converting — chill roll circulation
Chemicals storage — tank farm refrigeration
As a specialized China OH6 pump manufacturer with over three decades of high speed pump design and manufacturing experience, we deliver:
Full API 610 11th Edition (ISO 13709) compliance — designed, manufactured, and tested to the same rigorous standards as leading global brands
Proven integrally geared high speed technology — used in ammonia refrigeration, hydrocarbon, petrochemical, power, and general industrial applications worldwide
Competitive capital cost — typically 25–40% lower than major Western brands for equivalent API 610 OH6 configurations
Shorter lead times — 20–28 weeks ARO for standard material configurations (316L stainless steel); expedited delivery available for emergency requirements
Complete engineering documentation — including hydraulic performance curves (Q‑H, efficiency, NPSH3r), dimensional drawings (sectional, GA), API 610 data sheets, material certifications, noise data, and installation/maintenance manuals
Factory performance testing — witnessed and non‑witnessed options, including hydraulic performance testing, mechanical run testing, vibration monitoring, and bearing temperature monitoring on certified test loops
Low temperature qualification — component material verification for -30°C operation, including impact testing for low temperature toughness of wetted parts
Custom engineering — hydraulic design tailored to your exact ammonia refrigeration duty, material selection optimized for your specific operating conditions, and auxiliary system design to meet plant requirements
Global shipping and export packaging — wooden crates, VCI, desiccant, and full export documentation
Spare parts availability — critical spares (mechanical seals, bearings, gaskets, wear rings) stocked for standard sizes; complete spare parts kits available for scheduled overhauls
Technical support — pre‑sale application engineering (pump selection and sizing), on‑site installation and commissioning supervision, after‑sales warranty and parts support, training for operations/maintenance personnel
| Parameter | Specification |
|---|---|
| Pump Type | API 610 Type OH6 – vertical, integrally geared, single-stage overhung |
| Medium | Liquid ammonia (R717 refrigerant), anhydrous NH₃ |
| Specified Operating Condition | -30°C / 3.0 MPa (30 bar) system pressure |
| Design Temperature Range | -130°C to +340°C |
| Maximum Suction Pressure Capability | Up to 7.1 MPa (71 bar) and higher |
| Typical Flow Range (Ammonia refrigeration) | 5 – 150 m³/h (system‑dependent) |
| Typical Head Range | 300 – 1,500 m (staged by gear ratio selection) |
| Casing Construction | Vertical inline, partial-flow diffuser type |
| Impeller Type | Enclosed, high speed, Barske low NPSH inducer/impeller |
| Materials (Recommended) | 316L SS (casing, impeller, wetted parts); carbon steel (gearbox housing) |
| Seals | API 682 compliant, double seal with Plan 53B for ammonia zero‑leakage |
| Lubrication | Splash or forced oil (gearbox) |
| Maintenance | Cartridge design, 5+ years continuous operation between overhauls |
| Space footprint | Approximately 25% of equivalent horizontal multistage pump |
| Certification | API 610 11th Edition / ISO 13709 / ATEX (optional) |
For more information or a custom engineering proposal for your ammonia refrigeration circulation pump (-30°C liquid ammonia, 3.0MPa) application, please contact us at: