Hyrig’s Vacuum Bottoms Pump BB2 is a heavy duty centrifugal pump manufactured in full compliance with API 610 (ISO 13709), BB2 type. This horizontally mounted, radially split, two-bearing supported pump is specifically engineered for the challenging service of transferring vacuum residue (also known as vacuum tower bottoms, short residue, or reduced crude) from the vacuum distillation unit to downstream processes such as delayed coking, visbreaking, residue hydrotreating, or storage.
Why the BB2 configuration for vacuum bottoms?
Vacuum residue service presents multiple challenges:
High temperature: typically 350–420°C, up to 450°C for deep cut vacuum units
Low available NPSH (NPSHa) due to deep vacuum operation
High viscosity (often 500–5000 cSt at pumping temperature)
Potential presence of coke fines or catalyst particles
The BB2 configuration addresses these challenges through:
Two bearing supports – rigid rotor dynamics for high temperature stability
Centerline mounting – allows thermal expansion without shaft misalignment
Radially split casing – maintains casing integrity under thermal cycling
Optional double suction impeller – reduces NPSH requirement for larger flow rates (typically above 1000 m³/h)
Single suction with inducer – alternative for smaller flows where NPSH is critical
Typical Operating Parameters
| Parameter | Range |
|---|---|
| Flow rate | 50 – 2,500 m³/h (220 – 11,000 USgpm) |
| Head | 50 – 250 m (164 – 820 ft) |
| Temperature | 300°C – 450°C (572°F – 842°F) |
| Inlet pressure (at pump flange) | ≤10 bar (≤145 psi) – typically near atmospheric |
| Design pressure (casing) | 20 – 60 bar (dependent on customer specification) |
| Speed | 980 / 1480 / 2980 rpm (50/60 Hz) – slower speeds preferred for high viscosity |
Key Applications for Vacuum Bottoms Pump BB2
Delayed coker charge – pumping vacuum residue to coker heater
Visbreaker feed – residue transfer to visbreaker unit
Vacuum residue cooling loop – circulation through heat exchangers
Asphalt/bitumen production – feed to oxidizer or blending
Residue hydrotreating feed – to residue upgrading unit
Vacuum bottoms shipping – pipeline or tanker loading
Design Features for Reliable Vacuum Bottoms Service
High Temperature Materials
Casing and impeller: Carbon steel (ASTM A216 WCB) for up to 425°C; Chrome-moly (A217 WC6/WC9) for >400°C or higher pressure
Bearing housing cooling: Air cooled for moderate temperatures; water cooled (integral jacket) for pumped fluid >200°C
Sealing System (API 682)
Standard: Single cartridge seal with API Plan 62 (quench) and Plan 32 (external flush) to dilute coke fines
High reliability option: Tandem seal (Plan 52) or double seal (Plan 53) with external barrier fluid
Low NPSH Design
Inducer on single suction impeller – lowers NPSHr by 30–50%
Double suction impeller (for larger flows) – halves NPSHr compared to single suction
Wear Resistance
Hard faced wear rings (stellite or ceramic coating)
Optional abrasion resistant coatings for coke fines (tungsten carbide)
Comparison with Other Pump Types for Vacuum Bottoms
| Pump Type | Suitability | Notes |
|---|---|---|
| OH2 (overhung) | Limited | Nozzle loads and thermal growth problematic for large pumps |
| BB2 | Best fit | Ideal for 50–2500 m³/h, 50–250 m head, high temperature |
| BB3 (multistage) | Overkill | Unnecessary high pressure capability adds cost |
| Vertical canned | Not recommended | High temperature and solids cause seal/bearing issues |
Why Refineries Choose Hyrig Vacuum Bottoms Pump BB2
Proven reliability in high temperature, low NPSH vacuum residue service
API 610 compliance ensures minimum 20,000 hours bearing life and 3 years mean time between maintenance
Flexible material selection for sour residue (H₂S present) – upgrade to duplex stainless or Alloy 625 cladding
Global support and short lead times for API pumps
Need a Vacuum Bottoms Pump BB2 for your Vacuum Unit or Coker?
Contact Hyrig for a technical datasheet, custom engineering quote, or application review.
Email: info@hyrig.com