Hyrig Vacuum Bottoms Pump BB2 – API 610 Centrifugal Pump for Vacuum Residue Transfer

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Hyrig API 610 BB2 vacuum bottoms pump is designed for high temperature vacuum residue (vacuum tower bottoms) transfer. Handles up to 450°C, high viscosity, low NPSH. Single or double suction options. API 682 seals, heavy duty bearings, centerline mounting. Reliable continuous operation. Contact info@hyrig.com.

Conatct For Details
DetailReview(0)Additional

Hyrig’s Vacuum Bottoms Pump BB2 is a heavy duty centrifugal pump manufactured in full compliance with API 610 (ISO 13709), BB2 type. This horizontally mounted, radially split, two-bearing supported pump is specifically engineered for the challenging service of transferring vacuum residue (also known as vacuum tower bottoms, short residue, or reduced crude) from the vacuum distillation unit to downstream processes such as delayed coking, visbreaking, residue hydrotreating, or storage.

Why the BB2 configuration for vacuum bottoms?
Vacuum residue service presents multiple challenges:

  • High temperature: typically 350–420°C, up to 450°C for deep cut vacuum units

  • Low available NPSH (NPSHa) due to deep vacuum operation

  • High viscosity (often 500–5000 cSt at pumping temperature)

  • Potential presence of coke fines or catalyst particles

The BB2 configuration addresses these challenges through:

  • Two bearing supports – rigid rotor dynamics for high temperature stability

  • Centerline mounting – allows thermal expansion without shaft misalignment

  • Radially split casing – maintains casing integrity under thermal cycling

  • Optional double suction impeller – reduces NPSH requirement for larger flow rates (typically above 1000 m³/h)

  • Single suction with inducer – alternative for smaller flows where NPSH is critical

Typical Operating Parameters

ParameterRange
Flow rate50 – 2,500 m³/h (220 – 11,000 USgpm)
Head50 – 250 m (164 – 820 ft)
Temperature300°C – 450°C (572°F – 842°F)
Inlet pressure (at pump flange)≤10 bar (≤145 psi) – typically near atmospheric
Design pressure (casing)20 – 60 bar (dependent on customer specification)
Speed980 / 1480 / 2980 rpm (50/60 Hz) – slower speeds preferred for high viscosity

Key Applications for Vacuum Bottoms Pump BB2

  • Delayed coker charge – pumping vacuum residue to coker heater

  • Visbreaker feed – residue transfer to visbreaker unit

  • Vacuum residue cooling loop – circulation through heat exchangers

  • Asphalt/bitumen production – feed to oxidizer or blending

  • Residue hydrotreating feed – to residue upgrading unit

  • Vacuum bottoms shipping – pipeline or tanker loading

Design Features for Reliable Vacuum Bottoms Service

High Temperature Materials

  • Casing and impeller: Carbon steel (ASTM A216 WCB) for up to 425°C; Chrome-moly (A217 WC6/WC9) for >400°C or higher pressure

  • Bearing housing cooling: Air cooled for moderate temperatures; water cooled (integral jacket) for pumped fluid >200°C

Sealing System (API 682)

  • Standard: Single cartridge seal with API Plan 62 (quench) and Plan 32 (external flush) to dilute coke fines

  • High reliability option: Tandem seal (Plan 52) or double seal (Plan 53) with external barrier fluid

Low NPSH Design

  • Inducer on single suction impeller – lowers NPSHr by 30–50%

  • Double suction impeller (for larger flows) – halves NPSHr compared to single suction

Wear Resistance

  • Hard faced wear rings (stellite or ceramic coating)

  • Optional abrasion resistant coatings for coke fines (tungsten carbide)

Comparison with Other Pump Types for Vacuum Bottoms

Pump TypeSuitabilityNotes
OH2 (overhung)LimitedNozzle loads and thermal growth problematic for large pumps
BB2Best fitIdeal for 50–2500 m³/h, 50–250 m head, high temperature
BB3 (multistage)OverkillUnnecessary high pressure capability adds cost
Vertical cannedNot recommendedHigh temperature and solids cause seal/bearing issues

Why Refineries Choose Hyrig Vacuum Bottoms Pump BB2

  • Proven reliability in high temperature, low NPSH vacuum residue service

  • API 610 compliance ensures minimum 20,000 hours bearing life and 3 years mean time between maintenance

  • Flexible material selection for sour residue (H₂S present) – upgrade to duplex stainless or Alloy 625 cladding

  • Global support and short lead times for API pumps

Need a Vacuum Bottoms Pump BB2 for your Vacuum Unit or Coker?
Contact Hyrig for a technical datasheet, custom engineering quote, or application review.

Email: info@hyrig.com


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit