HYRIG VS6 API 610 vertical barrel pump replaces Sulzer SJD/SJV/JVCR/VPA, Flowserve WUC/WDC/WUCH/WUC-LN, and ITT Goulds VIC/3900/VICLN/VICR. Identical fit & performance. Cryogenic to 52 MPa. info@hyrig.com

Conatct For Details
DetailReview(0)Additional

Overview

HYRIG strictly follows API 610 11th/12th edition VS6 standards to design and manufacture vertical barrel pumps. With high reliability, low-temperature/high-pressure adaptability, full operating condition coverage, and superior cost performance, HYRIG VS6 provides a complete drop-in solution for replacing Sulzer, Flowserve, and ITT Goulds VS6 pump series. Perfectly suited for ethylene, propylene, C4, LPG, condensate, and other critical petrochemical services.


HYRIG VS6 – Positioning & Key Advantages

1. Standard & Construction Alignment

  • Full API 610 VS6 compliance – vertical multistage, double-case barrel pump, radially split, centerline support, low NPSH design.

  • Interchangeable dimensions – direct replacement for Sulzer SJD/SJV, Flowserve WUC/WDC, ITT Goulds VIC/3900 series. No foundation, piping, or motor modifications required.

  • Material consistency – covers carbon steel, LTCS, 304/316L, duplex, nickel alloys, meeting NACE, low-temperature, high-pressure, and corrosive service requirements.

  • Sealing & lubrication – API 682 mechanical seals or dry gas seals as standard, suitable for high-temperature, low-temperature, flammable, and easily vaporized media.

2. Performance Parameters – Full Coverage (Meeting or Exceeding OEMs)

ParameterHYRIG VS6SulzerFlowserveITT Goulds
Flow (m³/h)3 – 3,0005 – 1,2003 – 1,5004 – 1,300
Head (m)50 – 2,20080 – 1,80050 – 2,20060 – 2,000
Design Pressure (MPa)Up to 52.045.052.042.0
Temperature (°C)-200 to +480-196 to +450-200 to +480-100 to +425
Nozzle Size (inch)1.5″ – 16″2″ – 14″1.5″ – 16″2″ – 12″
Stages2 – 182 – 142 – 182 – 16

3. Core Technical Advantages (Replacement Competitiveness)

  • Cryogenic Series (-200°C) – HYRIG VS6-LN directly replaces Sulzer JVCR, Flowserve WUC-LN, ITT Goulds VICLN. Ideal for ethylene, propylene, and LNG deep-cold conditions.

  • High-Pressure Heavy-Duty Series (52 MPa) – HYRIG VS6-HP matches Sulzer VPA, Flowserve WUCH/WDC, ITT Goulds 3900. Suitable for high-pressure propylene, propane, and C4 feed.

  • Low NPSH First-Stage Impeller – Designed for flare condensate, off-spec LPG, C4, and other easily vaporized media. Superior cavitation resistance vs. OEMs.

  • Long-life design – 20-year design life, ≥3 years continuous trouble-free operation, >30% reduction in maintenance costs.

  • Cost performance – Price at 60–70% of international brands, 50% shorter lead time, localized spare parts supply.


Full VS6 Replacement List (23 Critical Petrochemical Pump Services)

Low-Temperature Light Hydrocarbons (Ethylene / Propylene / Propane)

ApplicationOEM Models ReplacedHYRIG VS6 ModelKey Parameters
Ethylene transfer / standby pumpSulzer JVCR/SJD-LN, Flowserve WUC-LN, ITT Goulds VICLNVS6-LN (-104°C)Q=20–400 m³/h, H=300–1200 m, T=-104°C
High-pressure propylene pump to PP unitSulzer SJD-API/VPA, Flowserve WUCH/WDC, ITT Goulds VICR/3900VS6-HPQ=10–300 m³/h, H=500–1800 m, P=4.0–6.0 MPa
Low-pressure propylene / off-spec propylene / loadingSulzer SJD, Flowserve WUC, ITT Goulds VICVS6-STDStandard range
Large-flow ship loading–VS6-LFQ=200–1200 m³/h
Propane to ethylene / propane transferSulzer SJD-API/SJD, Flowserve WUCH/WUC, ITT Goulds VICR/VICVS6-HP / VS6-STD–

C4 & Alkylation Services

ApplicationHYRIG Model
C4 cracking / raffinate C4 / C4 to alkylationVS6-STD / VS6-HP
Butene-1 pumpVS6-STD (low leakage)
Isobutane loading / isobutane to alkylationVS6-STD / VS6-HP

LPG & Utility Services

ApplicationHYRIG Model
Liquid hydrocarbon to ethylene / ship loadingVS6-HP / VS6-LF
Gas fractionation feed / off-spec LPGVS6-STD
Flare condensate pumpVS6-STD (low NPSH, intermittent duty)

Power / Condensate Services

ApplicationHYRIG Model
Condensate pumpVS6-STD (low NPSH, condensate duty)

HYRIG VS6 – Replacement Value Summary

  • 1:1 interchangeability – dimensions, performance, materials, and seals fully match international brands. Plug-and-play.

  • Full operating condition coverage – from cryogenic ethylene to high-pressure propylene, C4 alkylation to condensate – one-stop replacement for 23 petrochemical pump services.

  • Cost & time savings – 30–40% lower procurement cost, 50% shorter lead time, 30%+ reduction in spare parts and maintenance costs.

  • Reliability guarantee – API 610 compliant, 20-year design life, 3-year continuous operation, localized technical support.


Selection & Replacement Recommendations

  • New projects – Specify HYRIG VS6 directly. Same performance, significantly lower investment.

  • Retrofit / spare part replacement – HYRIG VS6 directly replaces existing Sulzer, Flowserve, or ITT Goulds VS6 pumps. Zero modification, zero risk.

  • Customization – For ultra-low temperature, ultra-high pressure, severe corrosion, NACE, and other special conditions, HYRIG offers customized hydraulic and material solutions.


Contact HYRIG

For model compatibility confirmation, technical drawings, or quotation – please provide your OEM pump model, serial number, or datasheet.

Email: info@hyrig.com

© HYRIG – High-performance pumping solutions for critical industries.

Direct Drop-in Replacements for Sulzer, Flowserve & Goulds API 610 Pumps (OH2, BB2, BB5, VS6)

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code
    Submit