Product Overview
The HYRIG VS6 LNG In-Tank Submerged Pump is a heavy-duty, multistage, vertical barrel (can type) centrifugal pump, fully compliant with API 610 (ISO 13709) standards. Specifically engineered for submerged installation inside LNG storage tanks – including full containment tanks, membrane tanks, and peak shaving vessels – this pump is immersed directly into the liquid natural gas (LNG) at –162°C. The VS6 vertical barrel configuration is ideal for this service because:
The entire pump (motor excluded) is submerged, eliminating suction NPSH problems – the static head of liquid above the pump provides all required net positive suction head.
The vertical design fits through standard tank roof openings (manways or dedicated pump column).
Multistage hydraulics provide sufficient head for long-distance pipelines, ship loading, and high pressure vaporizers without requiring an additional booster pump.
LNG pumps inside storage tanks must operate reliably for years without maintenance, with strict fugitive emission control and full cryogenic integrity. The HYRIG VS6 delivers high efficiency, long life, and safe containment for the world’s most demanding LNG terminals (export, import, and peak shaving).
Key Technical Parameters
Pump Type: API 610 VS6 Vertical Barrel, Multistage (2 to 10 stages), Submerged (wet stator motor is external – pump shaft extends down from top drive; pump barrel sits inside tank)
Flow Range: 100 – 4000 m³/h (typical LNG pump: 500–3000 m³/h for large terminals)
Head Range: 100 – 800 m (higher with more stages for high pressure send-out)
Working Temperature: –162°C (LNG boiling point at atmospheric pressure)
Design Pressure: Up to 25 bar (higher for deep tank or high discharge pressure)
Structure: Vertical barrel (can) fully submerged in LNG; suction inlet at bottom with strainer; pump barrel hangs from a top plate mounted on tank roof; shaft driven by electric motor at top (above tank roof).
Seal Standard: API 682 mechanical seal – tandem dry gas seal (Plan 72+75) with heated nitrogen barrier to prevent moisture ingress and ice formation; the seal is located at the top of the pump column, above the tank roof, in a dry, ambient environment.
Materials: Austenitic stainless steel (304L, 316L) for all wetted parts – fully Charpy impact tested at –196°C; fasteners and shaft from 316L or 17-4 PH; low magnetic permeability optional.
Application: LNG in-tank pumps for export terminals, import terminals, peak shaving plants, LNG bunkering vessels, and baseload liquefaction plants.
Key Features
API 610 VS6 Compliance – Built to the rigorous international standard for vertical, high reliability, continuous cryogenic pumps.
Zero NPSH Concern – Submerged design: the pump sits at the bottom of the LNG tank, with many meters of static liquid head above the suction; no cavitation risk even for saturated LNG.
High Flow & High Head Capability – Multistage design enables a single in-tank pump to send LNG directly to ship loading arms or vaporizers at pressures up to 80–100 bar (when followed by a booster pump). For lower head requirements, the multistage pump can be built with fewer stages.
Cryogenic Integrity – All wetted components 100% impact tested at –196°C; austenitic stainless steel retains excellent toughness; thermal contraction accommodated by vertical column design with expansion joints or slip joints.
Submerged Operation Safety – With no rotating parts exposed outside the pump column, and with the pump cooled directly by the LNG, there is no risk of leakage from dynamic seals at the pump casing. Only the top seal (above tank roof) is dynamic.
Leak‑Free Top Seal – API 682 tandem dry gas seal (Plan 72 + Plan 75) uses heated nitrogen buffer to prevent atmospheric moisture from freezing or entering the pump column, and ensures zero LNG emissions.
Heavy Duty Bearing System – Lower guide bearings (PTFE or carbon-graphite) lubricated by LNG; top bearings (above roof) are oil mist or grease lubricated, isolated from cold zone.
Modular Column Design – The pump column can be designed with removable sections for easy installation through tank manways; the entire pump cartridge can be withdrawn vertically for maintenance without tank degassing.
Low Magnetic Permeability (Optional) – For applications where magnetic particles could affect downstream processes (e.g., with magnetic bearings or sensitive instrumentation).
Full Cryogenic Performance Testing – Each pump is hydrostatically tested and can be optionally tested with liquid nitrogen at customer witness prior to shipment.
Typical Applications
In-tank LNG pump for export terminals (sending LNG from storage to ship loading lines)
In-tank pump for import terminals (transfer from cargo tanks to storage or send-out systems)
Peak shaving LNG storage (filling vaporizers during high demand periods)
LNG bunkering vessels and bunkering stations (pump inside vessel tank or shore tank to fuel LNG ships)
Baseload LNG liquefaction plant (pump from rundown tanks to loading or transport lines)
Liquid methane / liquid ethane storage services where VS6 submerged configuration is required
Why HYRIG?
HYRIG combines specialized LNG cryogenic engineering with API 610 VS6 reliability. Each VS6 LNG In-Tank Submerged Pump is designed with full impact tested stainless steel, submerged zero-NPSH hydraulics, API 682 top-mounted dry gas seal for zero emissions, easy pull‑out column design, and proven multistage performance at –162°C. Our VS6 pumps are operating in LNG terminals and peak shaving plants worldwide, delivering safe, reliable, and efficient in‑tank LNG transfer for decades.
Contact Us
For technical quotation, multistage hydraulic selection, cryogenic material certification, or custom engineered solutions for your LNG in‑tank pumping system, please email us at: info@hyrig.com
Our engineering team will respond within 24 hours with a pump selection optimized for your tank geometry, flow, head, and LNG send‑out requirements.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.