This page presents verified field cases of our API 610 VS6 vertical inline single‑stage process pumps operating reliably in straight‑through pipeline installations. Each case demonstrates the pump's space‑saving inline design, easy maintenance (back pull‑out), and stable performance in refinery boosting, petrochemical closed circulation, power plant auxiliary water, and chemical corrosive transfer applications.
Case 1 – Refinery Pipeline Inline Boosting (Middle East)
Background: A refinery needed to boost pressure of a diesel stream in an existing straight pipeline. Adding a horizontal pump would require extensive piping modifications (elbows, baseplate, foundation) and occupy valuable space in a congested pump area.
VS6 Pump Solution:
Flow: 250 m³/h
Head: 85 m
Temperature: 65°C
Material: Carbon steel casing, 316L impeller
Mounting: Foot mounted
Installation: Directly into existing pipeline flanges
Results:
No layout change – pump installed between existing pipe flanges like a spool piece
Stable pressure boosting – discharge pressure maintained within ±2% over wide flow range
Minimal footprint – no baseplate, no foundation, no additional piping
Easy maintenance – back pull-out allowed seal replacement without breaking pipe joints
Available references: Pipeline layout drawing (before/after), site photo, pressure log.
Case 2 – Petrochemical Closed Circulation System (Southeast Asia)
Background: A petrochemical plant required a high temperature (280°C) circulating pump for a heat transfer fluid loop. The system was located in a tight mezzanine with limited floor space. Horizontal pumps could not fit without major structural changes.
VS6 Pump Solution:
Flow: 180 m³/h
Head: 65 m
Temperature: 280°C
Material: 316L stainless steel
Mounting: Centerline mounted (for high temperature thermal stability)
Seal: API 682 Plan 23 jacketed seal
Results:
Low vibration – centerline mount eliminated thermal misalignment, vibration <1.8 mm/s
Long-term leak-free operation – no seal leakage after 2 years of continuous service
Space‑saving – vertical inline design fit within existing mezzanine without structural changes
Easy maintenance – back pull-out from top without draining the loop
Available references: Mezzanine layout drawing, site photo, vibration log.
Case 3 – Power Plant Auxiliary Water Pipeline (Asia)
Background: A power plant needed multiple inline water pressurization pumps for auxiliary service water. The pump room had limited space, and maintenance access was constrained.
VS6 Pump Solution:
Six VS6 pump sets (varying sizes)
Flow range: 80–350 m³/h
Head: 40–70 m
Temperature: 40°C
Material: Cast iron casing, bronze impeller
Results:
Compact layout – pumps installed directly in water pipelines, eliminating separate pump baseplates
Easy daily maintenance – all pumps accessible; back pull-out without disconnecting piping
Reliable operation – 18 months without any pump failure
Lower installation cost – no foundations, minimal piping changes
Available references: Pump room layout drawing, site photo, maintenance log.
Case 4 – Chemical Plant Corrosive Pipeline Transfer (China)
Background: A chemical plant needed to transfer a slightly corrosive solvent (dilute acid, 70°C) between two process areas. The existing pipeline was straight, and workshop space was very limited. Horizontal pumps would require costly piping reconfiguration.
VS6 Pump Solution:
Flow: 95 m³/h
Head: 55 m
Temperature: 70°C
Material: 316L stainless steel (casing, impeller, shaft)
Seal: API 682 Plan 53B dual mechanical seal
Results:
Inline installation saved workshop space – pump installed directly into existing straight pipeline, no elbows or baseplate
Handled corrosive medium – 316L material showed no corrosion after 2 years
Leak-free – dual seal with barrier fluid contained the acid safely
Simple maintenance – annual seal check without draining or cutting pipe
Available references: Workshop layout drawing, site photo, material certificate (EN 10204 3.1).
What You Can Request From Us for Each Case
Pipeline layout drawing (2D CAD, before/after installation)
Site photos and pump installation images
Project parameter sheet (flow, head, temperature, material, mounting)
Operating data (pressure, vibration, seal life)
Why Real Project Cases Matter
Field references prove that our VS6 pumps deliver:
No layout change, stable boosting in refinery pipelines (inline flange advantage)
Low vibration, leak-free high temp performance in petrochemical closed loops (centerline mount)
Compact layout, easy maintenance in power plant auxiliary water systems
Space‑saving, corrosive‑resistant transfer in chemical plants (316L, inline design)
Get the Complete VS6 Pump Case Study Package
We can match your inline pipeline conditions to similar successful installations. Request the VS6 pump project case PDF or ask for references in your specific industry.
Email: info@hyrig.com
Please specify your industry (refinery / petrochemical / power / chemical) and we will send relevant case studies, pipeline layout drawings, and technical data within 24 hours. We also welcome inquiries for custom VS6 vertical inline pump selection and factory direct pricing.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.