VS6 Pump Project Cases – API 610 Vertical Inline Pump for Refinery, Petrochemical, Power & Chemical Pipeline Service

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
Four VS6 pump successful cases. Case 1: Refinery pipeline inline boosting – API 610 VS6 vertical inline pump installed directly on process pipeline, no layout change, stable pressure boosting. Case 2: Petrochemical closed circulation system – centerline mounted VS6 for high temperature medium, low vibration, long-term leak-free operation. Case 3: Power plant auxiliary water pipeline – multiple VS6 pump sets for inline water pressurization, compact layout, easy daily maintenance. Case 4: Chemical plant corrosive pipeline transfer – 316L material VS6 pump handles corrosive medium, inline installation saves workshop space. Vertical inline flange design – installs directly in pipeline, saves floor space. Back pull-out for maintenance without pipe removal. Centerline mount option for high temp. We provide pipeline layout drawing, site photos, and project reference parameters.

Conatct For Details
DetailReview(0)Additional

This page presents verified field cases of our API 610 VS6 vertical inline single‑stage process pumps operating reliably in straight‑through pipeline installations. Each case demonstrates the pump's space‑saving inline design, easy maintenance (back pull‑out), and stable performance in refinery boosting, petrochemical closed circulation, power plant auxiliary water, and chemical corrosive transfer applications.


Case 1 – Refinery Pipeline Inline Boosting (Middle East)

Background: A refinery needed to boost pressure of a diesel stream in an existing straight pipeline. Adding a horizontal pump would require extensive piping modifications (elbows, baseplate, foundation) and occupy valuable space in a congested pump area.

VS6 Pump Solution:

  • Flow: 250 m³/h

  • Head: 85 m

  • Temperature: 65°C

  • Material: Carbon steel casing, 316L impeller

  • Mounting: Foot mounted

  • Installation: Directly into existing pipeline flanges

Results:

  • No layout change – pump installed between existing pipe flanges like a spool piece

  • Stable pressure boosting – discharge pressure maintained within ±2% over wide flow range

  • Minimal footprint – no baseplate, no foundation, no additional piping

  • Easy maintenance – back pull-out allowed seal replacement without breaking pipe joints

Available references: Pipeline layout drawing (before/after), site photo, pressure log.


Case 2 – Petrochemical Closed Circulation System (Southeast Asia)

Background: A petrochemical plant required a high temperature (280°C) circulating pump for a heat transfer fluid loop. The system was located in a tight mezzanine with limited floor space. Horizontal pumps could not fit without major structural changes.

VS6 Pump Solution:

  • Flow: 180 m³/h

  • Head: 65 m

  • Temperature: 280°C

  • Material: 316L stainless steel

  • Mounting: Centerline mounted (for high temperature thermal stability)

  • Seal: API 682 Plan 23 jacketed seal

Results:

  • Low vibration – centerline mount eliminated thermal misalignment, vibration <1.8 mm/s

  • Long-term leak-free operation – no seal leakage after 2 years of continuous service

  • Space‑saving – vertical inline design fit within existing mezzanine without structural changes

  • Easy maintenance – back pull-out from top without draining the loop

Available references: Mezzanine layout drawing, site photo, vibration log.


Case 3 – Power Plant Auxiliary Water Pipeline (Asia)

Background: A power plant needed multiple inline water pressurization pumps for auxiliary service water. The pump room had limited space, and maintenance access was constrained.

VS6 Pump Solution:

  • Six VS6 pump sets (varying sizes)

  • Flow range: 80–350 m³/h

  • Head: 40–70 m

  • Temperature: 40°C

  • Material: Cast iron casing, bronze impeller

Results:

  • Compact layout – pumps installed directly in water pipelines, eliminating separate pump baseplates

  • Easy daily maintenance – all pumps accessible; back pull-out without disconnecting piping

  • Reliable operation – 18 months without any pump failure

  • Lower installation cost – no foundations, minimal piping changes

Available references: Pump room layout drawing, site photo, maintenance log.


Case 4 – Chemical Plant Corrosive Pipeline Transfer (China)

Background: A chemical plant needed to transfer a slightly corrosive solvent (dilute acid, 70°C) between two process areas. The existing pipeline was straight, and workshop space was very limited. Horizontal pumps would require costly piping reconfiguration.

VS6 Pump Solution:

  • Flow: 95 m³/h

  • Head: 55 m

  • Temperature: 70°C

  • Material: 316L stainless steel (casing, impeller, shaft)

  • Seal: API 682 Plan 53B dual mechanical seal

Results:

  • Inline installation saved workshop space – pump installed directly into existing straight pipeline, no elbows or baseplate

  • Handled corrosive medium – 316L material showed no corrosion after 2 years

  • Leak-free – dual seal with barrier fluid contained the acid safely

  • Simple maintenance – annual seal check without draining or cutting pipe

Available references: Workshop layout drawing, site photo, material certificate (EN 10204 3.1).


What You Can Request From Us for Each Case

  • Pipeline layout drawing (2D CAD, before/after installation)

  • Site photos and pump installation images

  • Project parameter sheet (flow, head, temperature, material, mounting)

  • Operating data (pressure, vibration, seal life)

Why Real Project Cases Matter

Field references prove that our VS6 pumps deliver:

  • No layout change, stable boosting in refinery pipelines (inline flange advantage)

  • Low vibration, leak-free high temp performance in petrochemical closed loops (centerline mount)

  • Compact layout, easy maintenance in power plant auxiliary water systems

  • Space‑saving, corrosive‑resistant transfer in chemical plants (316L, inline design)

Get the Complete VS6 Pump Case Study Package

We can match your inline pipeline conditions to similar successful installations. Request the VS6 pump project case PDF or ask for references in your specific industry.

Email: info@hyrig.com

Please specify your industry (refinery / petrochemical / power / chemical) and we will send relevant case studies, pipeline layout drawings, and technical data within 24 hours. We also welcome inquiries for custom VS6 vertical inline pump selection and factory direct pricing.


Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code