The YG40-250 is an ISO 2858 vertical single-stage single-suction inline explosion-proof pipeline pump, engineered by HYRIG specifically for kerosene transfer in Iran’s oil depots, refinery process units, and aviation fuel refueling systems. It serves as a benchmark domestic alternative to the Sulzer BBS 40-250, offering 1:1 dimensional interchangeability, compact vertical construction, and dual safety protection (explosion-proof + anti-static).
Designed for Iran’s 50Hz power grid (380V/400V) and fully compliant with NIOC safety standards, this pump addresses the critical challenges of kerosene: flammability (flash point 28–45°C, explosion limit 0.7–5.0%), high volatility, electrostatic ignition risk, low viscosity (1.0–2.0 mPa·s at 20°C), wide temperature range (-20°C to +120°C), and outdoor high‑salt, dusty environments. With Ex d IIB T4 Gb flameproof construction, anti‑static brass impeller, vertical space‑saving design (1/3 footprint of horizontal pumps), low NPSHr ≤4.5m, API 682‑compliant mechanical seal (leakage ≤5 ppm), and IP54 protection, the YG40-250 delivers safe, reliable, energy‑efficient, and low‑installation‑cost kerosene transfer – ideal for Iran’s southern oil depots, Persian Gulf coastal refineries, and Zone 1 hazardous areas.
Iranian kerosene (including aviation fuel and industrial kerosene) presents unique challenges:
| Characteristic | Typical Condition | Risk / Requirement |
|---|---|---|
| Flammability | Flash point 28–45°C, explosion limit 0.7–5.0% | Zone 1 hazardous area – requires explosion‑proof equipment |
| Electrostatic ignition | Low conductivity fluid | Anti‑static materials (brass impeller) to prevent spark |
| Viscosity | 1.0–2.0 mPa·s at 20°C | Low, easy to pump – efficiency matters |
| Temperature range | -20°C (winter in north) to 120°C (refinery process) | Wide thermal capability required |
| Outdoor environment | High salt (Persian Gulf coast), dust, UV | Corrosion protection (IP54 + anti‑salt coating) |
| Installation space | Oil depots – limited footprint, dense piping | Vertical inline design saves space |
| Continuous operation | 8,000+ hours/year | High reliability, low maintenance |
The YG40-250 is optimized accordingly:
Ex d IIB T4 Gb flameproof enclosure – contains internal explosions, prevents ignition of external kerosene vapor. Flameproof joints width ≥12.5mm, gap ≤0.15mm per GB/T 3836.2-2021.
Anti‑static brass impeller – eliminates electrostatic discharge risk. Brass is naturally non‑sparking, unlike aluminum alloys.
Vertical inline structure – mounts directly into pipeline, occupies only 1/3 footprint of horizontal pumps. Ideal for space‑constrained depots.
Wide temperature range -20°C to +120°C – covers northern Iran winter kerosene and refinery high‑temperature process kerosene.
Low NPSHr ≤4.5m – prevents cavitation from volatile kerosene.
API 682 seal chamber – leakage ≤5 ppm, preventing vapor escape and explosion hazard.
IP54 + anti‑salt coating – resists coastal corrosion and dust ingress.
| Parameter | Value | Advantage over Sulzer BBS 40-250 |
|---|---|---|
| Model | YG40-250 | ISO 2858 design; performance curve overlap ≥98% – seamless replacement |
| Type | Vertical single‑stage single‑suction inline pipeline pump | Vertical structure – 1/3 footprint of horizontal; mounts directly into piping |
| Inlet/Outlet | DN40 (40 mm) | Same as BBS 40-250 – direct fit to existing piping |
| Flow Range | 20 – 80 m³/h (rated 40 m³/h) | Covers full BBS operating window – batch transfer & process circulation |
| Head Range | 200 – 250 m | Matches high‑pressure kerosene pipeline requirements |
| Design Pressure | 1.6 MPa (test 2.5 MPa) | 1.5× safety margin – hydrostatic tested |
| Temperature Range | -20°C to +120°C | Covers winter ambient to high‑temperature process kerosene |
| NPSH required | ≤ 4.5 m | Below industry average – prevents cavitation from volatile kerosene |
| Motor | 50Hz, 380V/400V (IEC) | Direct Iran grid connection – no VFD needed |
| Compliance | ISO 2858, JB/T53058-93, GB 3836 | Meets Iran ISIRI mandatory & Zone 1 hazardous area requirements |
| Impeller Material | High‑quality brass | Anti‑static, non‑sparking – eliminates electrostatic ignition risk |
| Casing Material | Cast iron (optional cast steel upgrade) | Durable, anti‑salt coating for coastal environment |
| Explosion Proof Rating | Ex d IIB T4 Gb | Flameproof per GB/T 3836.2-2021; joint width ≥12.5mm, gap ≤0.15mm |
| Enclosure Protection | IP54 | Dust‑protected, splash‑proof – suitable for outdoor Iran conditions |
| Mechanical Seal | API 682 Cat 2 cartridge (optional) | Leakage ≤5 ppm – prevents kerosene vapor escape |
| Hydraulic Efficiency | ≥ 74% | Optimized hydraulic model – energy‑saving for 24/7 operation |
| Vibration | ≤ 2.8 mm/s | Precision balanced impeller – low noise, long bearing life |
Ex d IIB T4 Gb flameproof enclosure:
Designed and certified per GB/T 3836.2-2021.
Flameproof joints: width ≥12.5mm, gap ≤0.15mm, surface roughness Ra≤6.3μm – prevents flame propagation.
Explosion‑proof cable glands and blanking plugs included – no downgrade risk.
Suitable for Zone 1 hazardous areas (typical for Iranian oil depots, refineries, and aviation fuel hydrant systems).
Anti‑static brass impeller:
Brass is naturally non‑sparking and electrically conductive, safely dissipating static charge.
Eliminates risk of electrostatic discharge ignition – critical for low‑conductivity fluids like kerosene.
Complies with anti‑static fan blade design standards for explosion‑proof motors.
Leakage control:
Optional API 682 Cat 2 cartridge mechanical seal with nitrogen buffer – leakage ≤5 ppm.
Prevents kerosene vapor accumulation, reducing explosion risk.
Footprint reduction: Vertical inline structure occupies only 1/3 of the floor space of a horizontal pump (e.g., BBS 40-250).
Direct pipeline mounting: No separate baseplate or foundation required – pump bolts directly into existing pipe flanges.
Lower civil works cost: Reduced building footprint and simpler installation – saves capital expenditure for Iranian oil depot projects.
Ideal for: Dense piping layouts, skid‑mounted systems, retrofit projects where space is limited.
Identical mounting dimensions to Sulzer BBS 40-250 – center height, flange positions (DN40), bolt pattern.
Flange compatibility – ISO, BS, or ANSI options available.
Performance curve overlap ≥98% – no process parameter adjustment.
Installation time: ≤8 hours (including alignment, seal connection, motor coupling).
Hydraulic efficiency ≥74% – achieved through advanced hydraulic modeling.
Energy saving: For a typical Iranian refinery or depot operating 24/7, 330 days/year, electricity at $0.30/kWh, the efficient design saves approximately $2,000–4,000 USD per year compared to lower‑efficiency pumps.
Procurement cost 30–40% lower than original Sulzer BBS 40-250.
Lead time ≤50 days (vs. 120+ days for imports).
IP54 protection – dust‑proof and splash‑proof. Suitable for outdoor operation in Iran’s dusty, high‑salt (Persian Gulf) environments.
Anti‑salt external coating – extends service life to ≥8 years in coastal conditions.
Standardized components – high parts commonality; maintenance without special tools.
Middle East spare parts warehouse (Dubai & Tehran) – emergency response ≤72 hours; normal spare parts (seals, bearings, impellers) supply ≤15 days. Spare part costs 40% lower than OEM.
Proven reliability – over 60,000 trouble‑free operating hours accumulated in flammable liquid service.
Manufacturer strength: YG series passed China Ministry of Machinery Industry pipeline pump product inspection in 1993. Designed to ISO 2858. Widely used for gasoline, diesel, kerosene, and aviation fuel.
Iran reference – Southern Iran oil depot aviation fuel transfer:
Service: Aviation kerosene (Jet A-1 equivalent)
Environment: Outdoor, high salt, high dust
Continuous operation: Over 2 years
Performance: No leakage, no safety incidents, zero static discharge events.
Certification: Passed ISIRI inspection and NIOC safety acceptance.
Bilingual documentation (English & Farsi/Persian) – includes Ex d IIB T4 certificate, ISO 9001, ISIRI CoC, material test reports. Smooth customs clearance.
| Application | Specific Role |
|---|---|
| Oil depot bulk transfer | Southern Iran oil depots, port terminals – kerosene receiving, storage transfer, truck loading. Vertical design saves space; explosion‑proof + anti‑static ensures safety. |
| Aviation fuel refueling | Airport hydrant systems, refueler truck loading – aviation kerosene (Jet A-1). Precise flow control, low leakage, NIOC approved for aviation fuel service. |
| Refinery process kerosene | Persian Gulf coastal refineries – kerosene treating units, product circulation. Wide temperature range (-20 to 120°C) handles both ambient and high‑temperature process streams. |
| Remote filling stations | Central Iranian chemical parks, remote fuel stations – kerosene dispensing. Easy maintenance, robust outdoor protection. |
ISO 2858 – international standard for end‑suction centrifugal pumps
JB/T53058-93 – Chinese pipeline pump industry standard
GB/T 3836.2-2021 – explosion‑proof enclosure (Ex d)
Ex d IIB T4 Gb – flameproof certification (Zone 1, gas group IIB, temperature class T4)
ISO 9001:2015 – quality management system
ISIRI Certificate of Conformity (CoC) – meets Iran import mandatory certification
Grid compatibility: 50Hz motor, 380V/400V voltage options, IP54 protection
7×24 technical support – via HYRIG Middle East partner service center (Dubai & Tehran)
Fault response ≤72 hours – on‑site or remote video guidance
Spare parts supply ≤15 days for mechanical seals, bearings, impellers, gaskets
Full documentation package – English/Persian IOM manuals, inspection reports, certificate of origin, ISIRI CoC, Ex certificate, material test certificates (MTC)
Standard configuration: Cast iron casing, brass impeller, Ex d IIB T4 motor (380V/50Hz), IP54, mechanical seal, base flange kit.
Upgrade options:
Cast steel casing – for higher pressure or corrosive environments
API 682 Cat 2 cartridge mechanical seal with nitrogen buffer – for lowest leakage (≤3 ppm)
316L stainless steel wetted parts – for coastal high‑chloride environments
Explosion‑proof Ex d IIB T4 – standard, already included
Recommended for: Kerosene, diesel, light fuel oils, aviation fuel. Not for gasoline (higher vapor pressure requires different NPSH analysis).
HYRIG supplies a full range of API 610 and ISO 2858 pumps for Iran’s oil, gas, petrochemical, and refinery industries:
OH2 – overhung, centerline mounted
BB1 / BB2 / BB3 – between‑bearing, radially split, single‑stage & multi‑stage
BB5 – between‑bearing, barrel type, multi‑stage high pressure
VS6 – vertical suspended, double‑casing
Vertical inline (YG series) – ISO 2858, space‑saving, explosion‑proof
We also offer complete Sulzer series replacements, including:
Sulzer BBS (BB2 equivalent)
Sulzer BBS 40-250 (horizontal / vertical alternative)
Sulzer OHH (OH2 equivalent)
Sulzer GSG (multistage ring section)
Sulzer ZE (heavy‑duty process pump)
For YG40-250 kerosene pump inquiries, technical support, sizing, or a quotation:
info@hyrig.com
HYRIG – Reliable, grid‑ready, and code‑compliant pumping solutions for Iran’s oil, gas, and petrochemical industry.
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.