YUKEN MPW-03-2-40 Pilot Check Valve | NG10, Hydraulic Lock

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
The YUKEN MPW-03-2-40 is a pilot-operated check valve (hydraulic lock) for both A and B lines. NG10 interface, cracking pressure 0.2 MPa. Maximum operating pressure 25 MPa, maximum flow 70 L/min.
Conatct For Details
DetailReview(0)Additional

YUKEN MPW-03-2-40 Pilot Check Valve (Hydraulic Lock)

Overview:

HYRIG can supply the YUKEN MPW-03-2-40 and related hydraulic components. The MPW-03-2-40 is a dual-line pilot-operated check valve used for load-holding in both A and B circuits.

Structure / Working Principle

The MPW-03-2-40 blocks flow in both A and B lines until pilot pressure is applied to release the check valves. The 0.2 MPa cracking pressure is the standard low-pressure option (0.2/0.4 MPa available).

Cross-Reference & Replacement

Confirm the dual A&B (MPW) configuration and 2 (0.2 MPa) cracking pressure when replacing. Single-line versions (MPA for A-line, MPB for B-line) are available for circuits that do not require dual locking.

Compatible Host Models

Used in YUKEN modular valve stacks. For related components, view YUKEN Check & Pilot Check Valves.

Selection Support

Need to confirm whether dual (MPW) or single (MPA/MPB) locking is required? Contact HYRIG with your circuit details.

Applications

Used for load-holding in both A and B lines, common in clamping, mold-locking, and lifting circuits.

Disclaimer: YUKEN is a registered trademark of YUKEN KOGYO CO., LTD. HYRIG is an independent supplier of hydraulic components and is not affiliated with YUKEN KOGYO CO., LTD.

Specifications:

  • **Mounting Standard**: ISO 4401-05 (CETOP 5)
  • **Mounting Bolt Pattern**: 4 × M6
  • **Approx. Weight**: 2.0 kg
  • Model Code: MPW-03-2-40
  • Valve Type: Pilot-operated check valve (hydraulic lock, sandwich plate)
  • Size: 03 (NG10 / CETOP 5)
  • Controlled Lines: A & B (dual)
  • Cracking Pressure: 0.2 MPa (code 2)
  • Maximum Operating Pressure: 25 MPa
  • Maximum Flow: 70 L/min
  • Design Number: 40

Contact Us:

For YUKEN MPW-03-2-40 selection, contact HYRIG: info@hyrig.com

Comment