| Model | Nominal Size | Max Inlet Pressure | Max Flow | Reduction Port |
|---|---|---|---|---|
| ZDR6D | DN6 | 31.5 MPa | 30 L/min | A / P |
| ZDR10D Valve | DN10 | 31.5 MPa | 50 L/min | A / B / P |
Data source: Technical data table.
Text-based mounting parameters for the ZDR6D valve:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-03 (CETOP 3) |
| Bolt Pattern | 4 x M5 threaded holes (40.5 x 40.5 mm) |
| Port Connections | A, B, P, T (Requires O-ring 9.25 x 1.78 mm) |
| Weight | Approx. 1.2 kg |
The valve is normally open. The pressure at the secondary side acts against the spring. When the pressure exceeds the set value, the spool moves to throttle the flow, maintaining constant reduced pressure. An internal relief function protects the secondary side from overpressure. The YM version includes an integral check valve for free reverse flow.
`ZDR6D` + `A/P` + `30` + `Y` + `Pressure Range (25/75/150/210)` + `M/YM`.
Used for precise pressure control in branch circuits of machine tools, injection molding machines, and hydraulic power packs.
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help choosing between A-port or P-port reduction? Contact our engineers with your circuit diagram.
Q: What is the maximum flow rate for the ZDR6D?
A: The maximum flow rate is 30 L/min.
Q: What is the function of the Y port?
A: The Y port is used for external drain of the control oil. It must be connected to the tank.
Q: What is the difference between M and YM?
A: M does not have a check valve. YM includes a check valve for free reverse flow.
For ZDR6D modular pressure reducing valve selection and spare parts, contact HYRIG: info@hyrig.com
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.