| Model | Nominal Size | Max Flow (L/min) | Feedback Type | Hysteresis | Spare Parts |
|---|---|---|---|---|---|
| 4WRE6 | DN6 | 65 | Electrical (Sensor) | < 1% | Amplifier Required |
| 4WRA6 Valve | DN6 | 43 | None (Proportional only) | < 6% | Amplifier Required |
| 4WRE10 Valve | DN10 | 260 | Electrical (Sensor) | < 1% | Amplifier Required |
Data source: Technical data table.
Mounting parameters for the 4WRE6 valve:
| Parameter | Specification |
|---|---|
| Mounting Interface | ISO 4401-03 (CETOP 3) |
| Bolt Pattern | 4 x M5 threaded holes (40.5 x 40.5 mm) |
| Port Connections | A, B, P, T (Requires O-ring 9.25 x 1.78 mm) |
| Body Width | 45 mm |
| Weight | 1.9 kg (2-position) / 2.6 kg (3-position) |
| Sensor Connection | 7-pin connector (Requires shielded cable) |
The 4WRE6 uses a proportional solenoid to push the spool. Unlike standard proportional valves, the 4WRE6 includes an inductive position sensor that constantly measures the spool position and sends a feedback signal to the amplifier. The amplifier compares the actual spool position with the command signal and adjusts the current to correct any deviation. This closed-loop control results in extremely high precision, low hysteresis, and excellent repeatability.
The 4WRE6 model code is structured as: `4WRE` + `6` + `Spool Type` + `10` + `Nominal Flow` + `24` + `Connector` + `Options`.
Example: `4WRE6E1-10/16Z4/M` = DN6, Spool E1, 16 L/min nominal flow, DC 24V, Z4 connector, mineral oil.
Replacing an old servo or proportional valve? Check:
Used in closed-loop control circuits requiring high precision, such as:
Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.
Need help choosing the correct spool type or matching amplifier? Explore related models: 4WRE10 Valve or contact our engineers with your system schematic.
Q: What is the advantage of the electric feedback (4WRE) over standard (4WRA)?
A: The 4WRE provides a closed-loop control system, reducing hysteresis to <1% and ensuring highly accurate, repeatable spool positioning even under varying pressure and temperature.
Q: Which amplifier is required for the 4WRE6?
A: The 4WRE6 requires a closed-loop amplifier, such as the VT-5005 series. It must be matched to the valve's position sensor.
Q: What is the maximum flow rate for this valve?
A: The 4WRE6 supports a maximum flow rate of 65 L/min.
Q: Do I need to bleed the air from the valve before use?
A: Yes, to ensure stable performance, use the air bleed screw on the valve body to remove trapped air before commissioning.
For 4WRE6 proportional directional valve selection and spare parts, contact HYRIG: info@hyrig.com