The Incremental Circulating Valve is a specialized bypass valve integral to well control contingency planning. It is run in the Bottom Hole Assembly (BHA) close to the drill bit prior to drilling into potential oil and gas zones.
Its sole purpose is to act as an emergency circulatory bypass. During a well kill operation, if the drill bit nozzles become obstructed by debris (a common occurrence in kick situations), circulating fluid down the drill string becomes impossible, halting the critical well control process. In this emergency scenario, the Incremental Circulating Valve is activated (typically by a combination of pressure cycles and ball drops), which opens its ports. This action creates a new, unimpeded circulation path above the blocked bit, allowing drilling personnel to continue pumping kill fluid to regain control of the wellbore pressure and safely circulate the influx out.
Technical Specifications:
| OD (mm/in) | ID (mm/in) | Ball Diameter (mm/in) | Connection |
|---|---|---|---|
| 105 (4-1/8) | 38 (1-1/2) | 38 (1-1/2) | NC31 B×P |
| 121 (4-3/4) | 50.8 (2) | 48 (1-7/8) | NC38 B×P |
| 160 (6-5/16) | 50.8 (2) | 65 (2-9/16) | NC46 B×P |
| 178 (7) | 57.2 (2-1/4) | 65 (2-9/16) | 5-1/2 FH B×P |
| 203 (8) | 57.2 (2-1/4) | 70 (2-3/4) | 6-5/8 REG B×P |
total 0 Sheet,Only 5 images can be uploaded, each less than 5m.