API ASME B16.5 Flange Bolt Length | L1 vs L2 Explained

2026-11-16 18:27

API ASME B16.5 Flange Bolt Length

HYRIG can supply API ASME B16.5 flanges. Correct bolting is critical for a leak-free joint. This guide explains the difference between L1 (stud bolt) and L2 (machine bolt) lengths and how to select the correct bolting for your Class 150 or 300 flange.

Key Facts

  • L1 Dimension: The length of a stud bolt (threaded rod with nuts on both ends). It excludes the nut height.
  • L2 Dimension: The length of a machine bolt (hex head on one end, nut on the other). It includes the head height.
  • Interchangeability: L1 and L2 values are not interchangeable. Mixing them up results in insufficient thread engagement or bottoming out.
  • Standard: ASME B16.5 Annex F provides the bolting length calculations.

Key Specifications

NPSDNL1 Stud (mm)L2 Machine (mm)
1/2155751
1256457
2508376
3808976
41008976
615010283
820010889
12300121102

Data source: Technical data table. Dimensions shown are for Class 150 RF flanges.

Dimensions

DimensionRequirement
L1 (Stud Bolt)Total threaded length. Verify nut height and washer usage.
L2 (Machine Bolt)Length from under the head to the end of the thread.
Thread EngagementTypically 1× bolt diameter minimum into the nut.
Grip LengthFlange thickness (b) + gasket thickness + flange thickness (b).

Structure and Working Principle

The bolting length is determined by the grip length of the joint. The grip length includes the thickness of both mating flanges, the gasket, and any washers.

  • A stud bolt (L1) is threaded on both ends. The required length is the grip length plus the height of two nuts (and any washers).
  • A machine bolt (L2) has a hex head on one end. The required length is the grip length plus the height of one nut (and washer), but the bolt length is measured from under the head, not including the head itself.

If a stud bolt (L1) is used in a calculation intended for a machine bolt (L2), it will be too short, resulting in inadequate thread engagement. Conversely, if a machine bolt is used where a stud is specified, it may bottom out in a blind hole or protrude excessively.

Cross-Reference and Replacement

When preparing a bolting RFQ for ASME B16.5 flanges:

  1. Confirm Bolt Type: Specify whether the project uses stud bolts (with two nuts) or machine bolts (with one nut).
  2. Verify Gasket Thickness: The gasket thickness is part of the grip length. If switching from a spiral wound gasket to a thicker soft gasket, the bolt length may need to be increased.
  3. Check Facing Type: The raised face height adds to the grip length. Ensure the bolting calculation accounts for the 1.6 mm RF.

Applications

  • Pipe Spool Fabrication: Ensuring the correct bolts are ordered for the flange joints.
  • Maintenance and Turnarounds: Replacing corroded bolts with the correct length to avoid joint failure.
  • High-Pressure Piping: Ensuring adequate thread engagement for Class 300 and above systems.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Frequently Asked Questions

Q: Why are there two different bolt lengths (L1 and L2)?

Because stud bolts and machine bolts are measured differently. L1 is the length of the threaded stud, while L2 is the length of the bolt from under the head.

Q: Can I use machine bolts in place of stud bolts?

It depends on the flange and the project specification. Stud bolts are generally preferred for high-pressure or high-vibration service because they provide more uniform clamping force. If replacing studs with machine bolts, the length must be recalculated.

Q: Do I need washers?

Washers are often used to distribute the bolt load and prevent galling on the flange surface. If washers are used, their thickness must be added to the grip length calculation.

Q: What is the typical lead time?

Standard lead time is 4 to 6 weeks depending on the flange size, class, and material.

Selection Support

To confirm the correct bolting for your flanges, provide the flange size, pressure class, gasket thickness, and bolt type. Our engineering team will confirm the L1 or L2 requirements.

Contact

For API ASME B16.5 flange selection, contact HYRIG: info@hyrig.com

Related Pages

Name:
Message:
Verification code:
Submit
Comment