API ASME B16.5 RF Flange | Class 150 & 300 Dimensions

QR code
share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
copy Link
Facebook
X
LinkedIn
Pinterest
Line
Tumblr
HYRIG can supply API ASME B16.5 RF flanges in Class 150 and Class 300. The RF (raised face) flange is the standard facing for these pressure classes, featuring a 1.6 mm raised surface that
Conatct For Details
DetailReview(0)Additional

API ASME B16.5 RF Flange

HYRIG can supply API ASME B16.5 RF flanges in Class 150 and Class 300. The RF (raised face) flange is the standard facing for these pressure classes, featuring a 1.6 mm raised surface that concentrates gasket compression inside the bolt circle. The tables cover NPS 1/2 to 24.

Key Facts

  • Design Standard: ASME B16.5
  • Facing Type: Raised Face (RF), 1.6 mm height
  • Pressure Class: Class 150 (PN20) / Class 300 (PN50)
  • Size Range: NPS 1/2 to NPS 24 (DN 15 to DN 600)
  • Bolt Data: Includes bolt hole, quantity, diameter, and lengths L1/L2
  • Gasket Matching: Spiral wound or ring gasket within RF diameter
  • Material Scope: Carbon steel (A105), stainless (F304/F316) per project

Key Specifications

NPSDNOD D (mm)Bolt Circle D1 (mm)RF Dia D2 (mm)Bolt Hole d (mm)Bolts (No. × Dia)L1 Stud (mm)L2 Machine (mm)
1/2158960.535164 × 1/2"5751
12510879.551154 × 1/2"6457
250152120.792194 × 5/8"8376
380190152.4127194 × 5/8"8976
4100229190.5157198 × 5/8"8976
6150279241.5216228 × 3/4"10283
8200343298.5270228 × 3/4"10889
12300483431.83812512 × 7/8"121102

Data source: Technical data table.

Dimensions

DimensionRequirement
Raised Face Height1.6 mm for Class 150/300 (additional to flange thickness b)
Flange OD (D)Per ASME B16.5 Class 150/300
Bolt Circle (D1)Per ASME B16.5 Class 150/300
Bolt Hole (d)Per ASME B16.5 Class 150/300
Stud Bolt Length (L1)Excludes nut height; confirm bolting standard
Machine Bolt Length (L2)Includes head; confirm bolting standard
Facing Finish125–250 AARH, serrated or concentric

Structure and Working Principle

The raised face creates a smaller gasket seating area above the bolt circle. Bolt load is concentrated on the gasket within the RF diameter, producing a higher seating stress than a flat face (FF) flange of the same class.

Two procurement variables require careful attention:

  1. RF height is additional to flange thickness. The 1.6 mm raised face is not included in dimension b; total stack height must account for it.
  2. L1 and L2 are not interchangeable. L1 is the stud bolt length (threaded rod with nuts at both ends); L2 is the machine bolt length (hex head on one end, nut on the other).

Cross-Reference and Replacement

When replacing or mating an existing RF flange, verify the following:

  1. Facing Type: RF cannot mate with RTJ or FF. If the existing flange is RTJ, a direct RF replacement will not seal.
  2. Bolt Length Type: Confirm whether the joint uses stud bolts (L1) or machine bolts (L2). Mixing them changes thread engagement.
  3. Raised Face Height: Class 150/300 RF is 1.6 mm. For higher pressure classes, confirm if a different RF height or RTJ facing is required.
  4. Gasket OD: The gasket must sit within the RF diameter D2; an oversized gasket will not be confined by the raised face.

Applications

  • General process piping: Default facing for Class 150/300 carbon steel and stainless steel lines in refineries and chemical plants.
  • Utility and water systems: Reliable sealing with spiral wound or soft gaskets at moderate pressure.
  • Retrofit and replacement: Matching existing ASME B16.5 RF flanges in maintenance and turnaround work.

Disclaimer: This equipment is designed for high-pressure industrial applications. Ensure strict compliance with local safety standards and verify pressure ratings prior to installation.

Frequently Asked Questions

Q: What is the difference between RF and FF flange?

RF concentrates bolt load on a raised gasket area inside the bolt circle; FF has no raised surface and is used for low-pressure or cast-iron mating equipment.

Q: Can an RF flange mate with an RTJ flange?

No. RF and RTJ faces are not interchangeable. The raised face cannot seal against a ring groove, and the RTJ ring cannot seat on a flat RF surface.

Q: What is the difference between L1 and L2 bolt length?

L1 is the stud bolt length (threaded rod with two nuts); L2 is the machine bolt length (hex head with one nut). They are not interchangeable.

Q: Is the 1.6 mm raised face included in flange thickness?

No. The raised face height is additional to the flange thickness dimension b.

Q: What gasket should be used with an RF flange?

Spiral wound or ring gaskets sized to sit within the RF diameter D2, with a surface finish of 125–250 AARH.

Selection Support

To confirm the correct RF flange for your piping class, provide the NPS, pressure class, facing requirement, bolt type (stud or machine), and material. Our engineering team will verify the dimensions and bolting against ASME B16.5.

Contact

For API ASME B16.5 RF flange selection, contact HYRIG: info@hyrig.com

Related Pages

Comment

comment
Name
Praise degree
Message:
Upload pictures:
    total 0 Sheet,Only 5 images can be uploaded, each less than 5m.
    Verification code